ML21029A068

From kanterella
Jump to navigation Jump to search
Requalification Inspection Notification Letter
ML21029A068
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 01/27/2021
From: Gerald Mccoy
Division of Reactor Safety II
To: Burchfield J
Duke Energy Carolinas
References
Download: ML21029A068 (5)


Text

January 27, 2021 J. Ed Burchfield, Jr.

Site Vice President, Oconee Nuclear Station Duke Energy Carolinas, LLC 7800 Rochester Highway Seneca, SC 29672-0752

SUBJECT:

REQUALIFICATION PROGRAM INSPECTION - OCONEE NUCLEAR STATION

Dear Mr. Burchfield:

During a telephone conversation on January 8, 2021, Mr. M. Meeks, Senior Operations Engineer, and Mr. C. Smith, Licensed Operator Continuing Training (LOCT) Supervisor, made arrangements for the NRC to inspect the licensed operator requalification program at the Oconee Nuclear Station. The inspection is planned for the week of March 15, 2021, which coincides with your regularly scheduled requalification examination cycle. The staff at your facility should prepare and conduct the requalification examinations in accordance with your NRC-approved requalification program. It is our understanding that you have committed to maintain your plant-referenced simulator in accordance with ANSI/ANS-3.5-2009, American National Standard for Nuclear Power Plant Simulators for Use in Operator Training and Examination.

In accordance with 10 CFR 55.59, the NRC has requested that you submit (by March 1, 2021),

the material as specified in paragraph A of the Enclosure, in order to support the NRC's inspection program needs. The NRC has further requested that you have all items as specified in paragraph B of the Enclosure available for review for the inspectors on the first day they arrive on site. Due to the current medical pandemic, the NRC inspectors have been directed to maximize the in office review portion of the inspection, in order to minimize on-site time. In accordance with this policy, the NRC is requesting that most of the inspection materials be provided before the on-site inspection (paragraph A of the Enclosure) in order to minimize the amount of materials required to be inspected on-site (paragraph B of the Enclosure). Mr.

Smith has been advised of this request and provided with the name and address of the NRC lead inspector assigned to this inspection.

This letter contains information collections that are subject to the Paperwork Reduction Act of 1995 (44 U.S.C. 3501 et seq.). These information collections were approved by the Office of Management and Budget, approval number Part 55 (3150-0018), which expires on July 22, 2022.

The public reporting burden for this collection of information is estimated to average 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> per response, including the time for reviewing instructions, gathering and maintaining the data needed, and completing and reviewing the collection of information.

J. Burchfield 2

Send comments on any aspect of this collection of information, including suggestions for reducing the burden, to the Information and Records Management Branch (T-6 F33), U.S.

Nuclear Regulatory Commission, Washington, DC 20555-0001, or by Internet electronic mail at infocollectsresource@nrc.gov; and to the Desk Officer, Office of Information and Regulatory Affairs, NEOB-10202, (3150-0101), Office of Management and Budget, Washington, DC 20503.

The NRC may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB approval number.

In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. (The Public Electronic Reading Room).

Thank you for your cooperation in this matter. If you have any questions regarding this inspection please contact Mr. Meeks at (404) 997-4467, (Internet E-mail:

Michael.Meeks@nrc.gov), or me at (404) 997-4551, (Internet E-mail: Gerald.McCoy@nrc.gov ).

Sincerely,

/RA/

Gerald J. McCoy, Chief Operations Branch 1 Division of Reactor Safety Docket Nos. 50-269, 50-270, 50-287 License Nos. DPR-38, NPF-47, DPR-55

Enclosure:

Materials Request List cc w/enclosure: via Listserv

J. Burchfield 3

SUBJECT:

REQUALIFICATION PROGRAM INSPECTION - OCONEE NUCLEAR STATION Dated January 27, 2021 ADAMS ACCESSION: ML#21029A068 OFFICE RII/DRS RII/DRS NAME M. Meeks G. McCoy DATE 1/27/2021 1/27/2021 OFFICIAL RECORD COPY

Enclosure Materials Request List The items listed below are necessary to support the Licensed Operator Requalification Program inspection (IP-71111.11) in March, 2021, at the Oconee Nuclear Station. Items listed under In-office inspection material must be received in the NRC Region II office by March 1, 2021. Items listed under On-site inspection material should be ready for review upon arrival of the inspectors on March 16, 2021.

A.

In-office inspection material:

1. Complete list of all licensed individuals (active and inactive; RO and SRO) including license restrictions.
2. Copy of an Organizational Chart for the training department including simulator staff.
3. Spreadsheets and/or test outlines which show the usage of written examination questions, JPMs, and simulator scenarios (i.e., outlines/sample plans).
4. Copy of the weekly examination schedules for the weeks that the 2021 annual operating exams will be administered, including a list of personnel scheduled for testing the week of March 15, 2021.
5. Copies of the approved written examinations that were (or will be) administered for the most recent biennial requalification examination (for all weeks), including all re-take examinations.
6. Ten (10) job performance measures (JPMs), both simulator and in-plant, and four (4) simulator scenarios associated with the current annual operating test. The JPMs and scenarios to be reviewed should include those that will be administered the week of March 15, 2021, with any remaining JPMs and scenarios reviewed selected from other weeks of the annual operating test. (exam security related item)
7. Self-assessment reports, corrective action reports, and Licensee Event Reports, written since the last requalification inspection, resulting from or concerning human performance errors, including any examination security issues.
8. A copy of site procedure(s) governing the conduct (process and content) of license operator requalification training (classroom and simulator), examination development/administration, remedial training, and examination security.
9. A copy site procedure(s) governing simulator configuration control, maintenance, and fidelity, including all testing methods used to fulfill ANSI/ANS-3.5-2009 requirements.
10. Copy of the program evaluation of the previous biennial requalification cycle.
11. Requalification training attendance records for the current biennial training cycle.
12. Examination results since last requalification inspection (weekly operating & written examinations).

2

13. Complete list of all individuals that reactivated their licenses since the last requalification inspection.
14. Records associated with license reactivation, including:
a. Documentation of time on shift under instruction.
b. Security system and HP/dosimetry records for plant areas toured by reactivating individual and accompanying licensed operator.
15. Records providing documentation of maintenance of active license status (time on shift) for all licensed operators since last requalification inspection.
16. Medical records for a selected sample of licensed operators.
17. Simulator maintenance and testing records, including:
a. List of all open simulator discrepancies
b. List of all simulator discrepancies closed within the past 12 months
c. List of simulator performance tests B. On-site inspection material:
1. Additional copies of all simulator scenarios and JPMs (in-plant and simulator) that will be administered for the annual operating examination during the week of March 15, 2021 (for the NRC inspectors to use during direct observation of the exam activities).
2. Simulator maintenance and testing records, including:
a. Simulator performance testing records as requested by the NRC inspectors (i.e., Scenario Based Testing (SBT) records) and associated documentation