ML21014A516

From kanterella
Jump to navigation Jump to search

Louisiana Energy Services - RAI for Annual Decommissioning Fund Cost Estimate (Enterprise Project Identifier L-2020-DFA-0006)
ML21014A516
Person / Time
Site: 07003103
Issue date: 01/14/2021
From: Blair Angella Love
URENCO USA, URENCO USA Energy Services, Urenco, Urenco, Ltd
To: Sturzebecher K
NRC/NMSS/DFM/FFLB
KJSturzebecher-NMSS/DFM/FFL-301.415.8534
References
EPID L-2020-DFA-0006
Download: ML21014A516 (4)


Text

From:

Love, Barry To:

Sturzebecher, Karl Cc:

Bixenman, Andrew B.; Ramsey, Kevin; Turtil, Richard

Subject:

[External_Sender] RE: Query on 2020 Annual Decommissioning Funding Cost Estimate / Request for additional information regarding the DFCE Date:

Thursday, January 14, 2021 2:01:28 PM Attachments:

image001.png

Karl,

In response to your email request for the additional information, UUSA is providing the following information:

Factor #1: Spills of radioactive material - Since the last Decommissioning Funding Plan (DFP)

update, has LES experienced any spills or leaks that resulted in contamination that could not be removed?

Yes. On 8/5/2020, there was a Leak in the Chemical Laboratory sink resulting in an addition of 4 sqft of fixed contamination. The total Fixed Contamination Areas at UUSA is now 75 sqft.

Factor #4: Facility modifications - Provide a narrative describing the facility whether there have been facility modifications since the previous DFP, the latest DFP should clearly describe the changes, and the detailed breakdown of costs should include decommissioning any modifications to the facility.

The recent Decommissioning Funding Cost provided in correspondence LES-20-00079 on September 3, 2020 does not include increases as a result in facility modification from the previous DFP provided in correspondence LES-19-140 on October 14, 2019. The facility has not been modified resulting in changes to the number of cascades being operated or buildings in commission, nor have we made changes to the facility that would have a relevant impact on decommissioning costs.

Please contact me if you have any additional questions.

Thank you,

Barry Love Licensing Specialist

UUSA l P.O. Box 1789 l Eunice l New Mexico l 88231 l USA Tel: +1 (575) 394-4482 l Email: Barry.Love@urenco.com l Web: www.uusa.urenco.com

From: Sturzebecher, Karl [1]

Sent: Thursday, January 7, 2021 11:09 AM To: Love, Barry <Barry.Love@urenco.com>

Cc: Bixenman, Andrew B. <Andrew.Bixenman@urenco.com>; Ramsey, Kevin

<Kevin.Ramsey@nrc.gov>; Turtil, Richard <Richard.Turtil@nrc.gov>

Subject:

RE: Query on 2020 Annual Decommissioning Funding Cost Estimate / Request for additional information regarding the DFCE

Hello Barry, I wanted to follow up from the earlier email (below) and cover the background information along with the basis for the request for additional information. We have reviewed your letter dated September 3, 2021, transmitting the 2020 Annual Decommissioning Funding Cost Estimate (DFCE). The letter is available in the Agencywide Documents Access and Management System (ADAMS) under Accession Number ML20255A131. Our review of your application has identified that additional information is needed.

Specifically, when updating the DFCE, the Decommissioning Planning Rule requires licensees to consider the effect of eight factors, outlined in 10 CFR 70.25(e)(2), on their DCEs. In the 2020, submittal, LES addressed the eight factors, however, the following two factors need additional information:

Factor #1: Spills of radioactive material - Since the last Decommissioning Funding Plan (DFP) update, has LES experienced any spills or leaks that resulted in contamination that could not be removed?

and

Factor #4: Facility modifications - Provide a narrative describing the facility whether there have been facility modifications since the previous DFP, the latest DFP should clearly describe the changes, and the detailed breakdown of costs should include decommissioning any modifications to the facility.

The additional information requested above should be provided within 10 days from the date of this message. This information is needed to verify compliance with 10 CFR 70.25, Financial assurance and recordkeeping for decommissioning.

Pending your response, we anticipate completing our review by February 21, 2021. This date could change depending on the findings of our technical review, urgent assignments, or other factors. We will promptly communicate any significant changes to this schedule.

In accordance with Title 10 of the Code of Federal Regulations, Section 2.390 of the NRCs Agency Rules of Practice and Procedure, a copy of this message will be available for public inspection in the NRC Public Document Room or from ADAMS. The ADAMS database is accessible from the NRC Web site at http://www.nrc.gov/readingrm/

adams.html (the Public Electronic Reading Room).

Please let me know if you have any questions regarding this request for additional information.

Thank you, Karl Sturzebecher NMSS/DFM/Fuel Facility Licensing Branch U.S. Nuclear Regulatory Commission Washington, DC 20555 C: 443-676-3495 T: 301-415-8534 E: Karl.Sturzebecher@nrc.gov

From: Sturzebecher, Karl Sent: Thursday, January 07, 2021 7:38 AM To: Love, Barry <Barry.Love@urenco.com>

Cc: Bixenman, Andrew B. <Andrew.Bixenman@urenco.com>; Ramsey, Kevin

<Kevin.Ramsey@nrc.gov>; Turtil, Richard <Richard.Turtil@nrc.gov>

Subject:

Query on 2020 Annual Decommissioning Funding Cost Estimate

Barry, For the Decommissioning Fund request, please provide feedback on the following:
1. Since the last Decommissioning Funding Plan update, has LES experienced any spills or leaks that resulted in contamination that could not be removed?
2. A narrative describing the facility should be included in the DFP. If there have been facility modifications since the previous DFP, the latest DFP should clearly describe the changes, and the detailed breakdown of costs should include decommissioning any modifications to the facility.
3. Please confirm there has been no change in possession limits.

If you have any questions please call.

Thank you, Karl

Karl Sturzebecher NMSS/DFM/Fuel Facility Licensing Branch U.S. Nuclear Regulatory Commission Washington, DC 20555 C: 443-676-3495 T: 301-415-8534 E: Karl.Sturzebecher@nrc.gov

This email transmission is confidential Louisiana Energy Services, LLC and intended solely

for the person or organization to which it is addressed. If you are not the intended recipient, you must not copy, distribute or disseminate the information or take any action in reliance of it. Any views expressed in this message are those of the individual sender, except where the sender specifically states them to be the views of any organization or employer. If you have received this message in error, do not open any attachment but please notify the sender (above) and delete this message from your system. Please rely on your own virus check, as no responsibility is taken by the sender for any damage arising out of any bug or virus.