Category:Emergency Preparedness-Emergency Plan
MONTHYEARML24122B3032024-04-29029 April 2024 Associated Independent Spent Fuel Storage Installation, Revision to Emergency Plan Report of Change ML23352A3692023-12-18018 December 2023 Associated Independent Spent Fuel Storage Installation, Revision to Emergency Plan Report of Change ML23054A2582023-02-22022 February 2023 And Associated Independent Spent Fuel Storage Installation Revision to Emergency Plan Report of Change ML22312A5502022-11-0707 November 2022 Proposed License Amendment Request to Revise Emergency Plan Staff Augmentation Times ML22160A3852022-06-0909 June 2022 Associated Independent Spent Fuel Storage Installations - Revision to Emergency Plan Report of Change ML21014A3702021-01-14014 January 2021 Associated Independent Spent Fuel Storage Installations - Revision to Emergency Plan Report of Change ML18169A2272018-06-13013 June 2018 Attachment 3 - Proposed NAPS Emergency Plan Changes ML18025B4932018-01-16016 January 2018 Attachments 7 & 8: Surry - Proposed Changed SPS Emergency Plan Pages and Offsite Response Agency Letters of Concurrence ML18025B4912018-01-16016 January 2018 Attachments 5 and 6: North Anna - Proposed Changed to Emergency Plan Pages and Marked-Up SPS Emergency Plan Page Changes ML15021A3072015-01-14014 January 2015 (SPS) Units 1, 2 and ISFSIs - Revisions to North Anna and Surry Power Station Emergency Plans ML0402901242004-01-21021 January 2004 ISFSI - Revision 47 to the Emergency Plan 2024-04-29
[Table view] Category:Letter
MONTHYEARML24302A1762024-10-22022 October 2024 Core Operating Limits Report Surry 2 Cycle 33 Pattern Hot Revision 0 ML24283A0702024-10-0707 October 2024 Annual Submittal of Technical Specifications Bases Changes Pursuant to Technical Specification 6.4.J IR 05000280/20240102024-10-0202 October 2024 Biennial Problem Identification and Resolution Inspection Report 05000280/2024010 and 05000281/2024010 ML24270A0022024-09-25025 September 2024 Inservice Inspection Owners Activity Report (OAR) ML24248A1712024-09-0303 September 2024 Proposed License Amendment Request - Temporary Service Water Supply to the Component Cooling Heat Exchangers IR 05000280/20240052024-08-26026 August 2024 Updated Inspection Plan for Surry Power Station, Units 1 and 2 (Report 05000280/2024005 and 05000281-2024005), Rev 1 ML24219A2372024-08-23023 August 2024 Issuance of Amendment Nos. 319 and 319, Adoption of TSTF-577, Rev. 1, Revised Frequencies for Steam Generator Tube Inspection, ML24207A0402024-08-21021 August 2024 Summary of July 17, 2024, Public Meeting - TS 3.7/3.14 AOT for SW Piping Maintenance IR 05000280/20240112024-08-13013 August 2024 Comprehensive Engineering Team Inspection Report 05000280/2024011 and 05000281/2024011 ML24164A0012024-08-12012 August 2024 Proposed Alternative Relief Request V-1 Inservice Testing of Pressure Isolation Valves (EPID l-2023-LLR-0060) IR 05000280/20240022024-08-0101 August 2024 Integrated Inspection Report 05000280/2024002 and 05000281/2024002 05000280/LER-2024-001, Troubleshooting Initiated Unknown Turbine Trip Feature in Control System2024-07-30030 July 2024 Troubleshooting Initiated Unknown Turbine Trip Feature in Control System ML24165A2782024-07-17017 July 2024 Issuance of Amendment Nos. 318 and 318, Reclassification of Regulatory Guide 1.97 Variable for Low Head Safety Injection ML24165A1232024-07-17017 July 2024 Proposed Alternative Relief Request P-1, P-2 Inservice Testing of Residual Heat and Containment Spray Pumps (EPID l-2023-LLR-0058) ML24190A4192024-07-0808 July 2024 Inservice Testing (IST) Program for Pumps and Valves Revised Sixth IST Interval Start Date and Updated Technical Specifications References for Alternative Request V-1 ML24179A2932024-07-0101 July 2024 Notification of Inspection and Request for Information for NRC Problem Identification and Resolution Inspection ML24178A2422024-06-25025 June 2024 2023 Annual Report of Emergency Core Cooling System (ECCS) Model, Changes Pursuant to the Requirements of 10 CFR 50.46 ML24177A2792024-06-20020 June 2024 Preparation and Scheduling of Operator Licensing Examinations ML24166A0622024-06-18018 June 2024 – Proposed Alternative Relief Request P-3, P-4 Inservice Testing of Boric Acid, Component Cooling Water Pumps ML24157A0542024-06-13013 June 2024 Audit Summary in Support of License Amendment Request for Proposed Reclassification of Low Head Safety Injection Flow Instrumentation Related to Regulatory Guide 1.97 ML24143A1622024-06-12012 June 2024 – Correction to Issuance of Amendment Nos. 297 and 280 and Surry Units 1 and 2, Correction to Issuance of Amendment Nos. 317 and 317, to Change Emergency Plan Staff Augmentation Times ML24170B0532024-06-10010 June 2024 DOM-NAF-2-P/NP-A, Revision 0.5, Reactor Core Thermal-Hydraulics Using the VIPRE-D Computer Code ML24141A2862024-05-22022 May 2024 Information Request for the Cyber Security Baseline Inspection, Notification to Perform Inspection 05000280/2024403 and 05000281- 2024403 IR 05000280/20244032024-05-22022 May 2024 Information Request for the Cyber Security Baseline Inspection, Notification to Perform Inspection 05000280/2024403 and 05000281- 2024403 ML24141A2512024-05-20020 May 2024 Proposed License Amendment Request - Reclassification of Low Head Safety Injection Flow Indication Regulatory Guide 1.97 Variable - Supplemental Information ML24141A0482024-05-17017 May 2024 EN 56958_1 Ametek Solidstate Controls, Inc ML24136A2302024-05-13013 May 2024 Core 1 Cycle 33 Pattern Mdr Revision 0 ML24130A2032024-05-0909 May 2024 Proposed License Amendment Request Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections Supplemental Information ML24130A2492024-05-0909 May 2024 Submittal of Information in Support of Surry Power Station Unit 1 Thermal Shield Flexure Replacement Campaign ML24130A1192024-05-0707 May 2024 Inservice Test Program for Pumps and Valves Sixth Interval Update and Associated Relief and Alternative Requests - Response to Request for Additional Information Regarding Alternative Request V-1 ML24142A3852024-04-30030 April 2024 2023 Annual Radioactive Effluent Release Report IR 05000280/20240012024-04-30030 April 2024 Integrated Inspection Report 05000280-2024001 and 05000281-2024001 ML24122C6522024-04-30030 April 2024 Annual Radiological Environmental Operating Report IR 05000280/20244022024-04-29029 April 2024 Security Baseline Inspection Report 05000280/2024402 and 05000281/2024402 ML24122B3032024-04-29029 April 2024 Associated Independent Spent Fuel Storage Installation, Revision to Emergency Plan Report of Change ML24115A1952024-04-24024 April 2024 Notification of Surry Power Station Comprehensive Engineering Team Inspection - U.S. NRC Inspection Report 05000280/2024011 and 05000281/2024011 ML24054A0142024-04-22022 April 2024 Issuance of Amendment Nos. 297 and 280, and Surry Power Station Unit Nos. 1 and 2, Issuance of Amendment Nos. 317 and 317, to Change Emergency Plan Staff Augmentation Times ML24108A1812024-04-15015 April 2024 Proposed License Amendment Request - Reclassification of Low Head Safety Injection Flow Indication Regulatory Guide 1.97 Variable Supplemental Information ML24095A2172024-04-12012 April 2024 – Review of the Spring 2023 Steam Generator Tube Inspection Report ML24088A2482024-03-26026 March 2024 Inservice Testing Program for Pumps and Valves Sixth Interval Update and Associated Relief and Alternative Requests- Response to Request for Additional Information ML24087A2082024-03-22022 March 2024 Proposed License Amendment Request Addition of Containment Limiting Condition for Operation and Surveillance Requirements ML24078A2642024-03-21021 March 2024 – Regulatory Audit in Support of License Amendment Request to Proposed Reclassification of Regulatory Guide 1.97 Variable for Low Head Safety Injection Flow Instrumentation ML24087A1522024-03-18018 March 2024 Annual Changes, Tests, and Experiments Report Regulatory Commitment Evaluation Report ML24023A5762024-03-0808 March 2024 Correction to Issuance of Amendment Nos. 315 and 315, Regarding Revised Emergency Plan for Relocation of the Technical Support Center IR 05000280/20230062024-02-28028 February 2024 Annual Assessment Letter for Surry Power Station, Units 1 and 2 - NRC Inspection Reports 05000280/2023006 and 05000281/2023006 ML24032A4712024-02-20020 February 2024 Exemption from Select Requirements of 10 CFR Part 73 - Security Notifications, Reports, and Recordkeeping and Suspicious Activity Reporting ML24051A1782024-02-19019 February 2024 Proposed License Amendment Request - Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections ML24057A0612024-02-19019 February 2024 And Virgil C. Summer Power Nuclear Stations - Nuclear Property Insurance Coverage IR 05000280/20230042024-02-0909 February 2024 Integrated Inspection Report 05000280/2023004 and 05000281/2023004 IR 05000280/20244012024-02-0606 February 2024 Security Baseline Inspection Report 05000280/2024401, 05000281/2024401 and 07200002/2024401 2024-09-03
[Table view] |
Text
VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 January 14, 2021 ATTN: Document Control Desk Serial No.: 21-009 U.S. Nuclear Regulatory Commission NRA/ENC: RO Washington, DC 20555-0001 Docket Nos.: 50-280/281 72-2/55 License Nos.: DPR-32/37 SNM-2501 VIRGINIA ELECTRIC AND POWER COMPANY (DOMINION ENERGY VIRGINIA}
SURRY POWER STATION UNITS 1 AND 2 AND ASSOCIATED INDEPENDENT SPENT FUEL STORAGE INSTALLATIONS REVISION TO EMERGENCY PLAN REPORT OF CHANGE Pursuant to 10 CFR 50.54(q)(5) and 10 CFR 72.44(f), a summary of the change analysis for Revision 6, effective December 15, 2020, to the Surry Power Station (SPS)
Emergency Action Level (EAL) Matrix and Technical Basis Document is provided in the Attachment. The EAL Matrix is discussed in Section 4.2, "Emergency Classification System," of the Surry Emergency Plan. Incorporated by reference, the EAL Matrix tables and Technical Basis Documents are part of the Emergency Plan.
The revision incorporates changes that did not require prior NRC approval and do not implement actions that reduce the effectiveness of the SPS Emergency Plan. The
. Emergency Plan continues to meet the standards of 10 CFR 50.47(b) and Appendix E.
If you have any questions or require additional information, please contact Erica Combs at 804-273-3386.
Sincerely,
~-
Mark D. Sartain Vice President Nuclear Engineering & Fleet Support Commitments made by this letter: None Attachments: Surry Power Station, Emergency Action Level Matrices and Technical Basis Document, Revision 6, 10 CFR 50.54(q) Summary
Serial No.: 21-009 Docket Nos.: 50-280/50-281 72-2/72-55 Page 2 of 2 cc: Regional Administrator, Region II U.S. Nuclear Regulatory Commission Marquis One Tower 245 Peachtree Center Avenue, NE, Suite 1200 Atlanta, Georgia 30303-1257 ATTN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U. S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Mr. Vaughn Thomas NRG Project Manager - Surry Power Station U.S. Nuclear Regulatory Commission Mail Stop 04 F-12 One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2738 Ms. Yen-Ju Chen NRG Senior Project Manager - ISFSls U. S. Nuclear Regulatory Commission Mail Stop 4B34 Two White Flint North 11545 Rockville Pike Rockville, Maryland 20852-2738 NRG Senior Resident Inspector Surry Power Station
Serial No.: 21-009 Docket Nos.: 50-280/50-281 72-2/72-55 ATTACHMENT Surry Power Station, Emergency Action Level Matrices and Technical Basis Document, Revision 6 10 CFR 50.54(q) Summary
)
Surry Power Station - Units 1 and 2 Surry Independent Spent Fuel Storage Installations Virginia Electric and Power Company (Dominion Energy Virginia)
Serial No.: 21-009 Docket Nos.: 50-280/50-281 72-2/72-55 Attachment, Page 1 of 1 Surry Power Station Emergency Action Level Matrices and Technical Basis Document, Revision 6 1 10 CFR 50.54(q) Summary The Emergency Action Level (EAL) Matrix is discussed in Section 4.2, "Emergency Classification System," of the Surry Power Station Emergency Plan. Incorporated by reference, the EAL Matrix tables and Technical Basis Documents (TBDs) are part of the Emergency Plan. Revision 69 of the SPS Emergency Plan incorporated new EALs developed using the NRG endorsed guidance in NEI 99-01, Revision 6 [1].
Revision 6 of the SPS EAL Matrix corrects an administrative error in MS6.1.
Specifically, a reference to Reactor Trip switches and breakers was added in error during printing:
"An automatic or manual trip (Rx Trip Switches OR opening breakers 32B and 32N) did not shut down the reactor as indicated by reactor power ~%5."
MS6.1 was revised to align with the approved language used in NEI 99-01, Revision 6:
"An automatic or manual trip did not shut down the reactor as indicated by reactor power ~%5."
This change was editorial in nature and does not reduce the effectiveness or the regulatory bases of the Emergency Plan.
The EAL TBD for Surry Power Station was updated from Revision 5 to Revision 6. The changes to the EAL TBD are editorial to align the revision number to the EAL Wallcharts and, therefore, continue to maintain the effectiveness of the SPS Emergency Plan.
REFERENCES
- 1. NEI 99-01, "Methodology for the Development of Emergency Action Levels for non-Passive Reactors," Revision 6, dated November 2012. (ADAMS Accession No. ML19305D248)