ML20309A591

From kanterella
Jump to navigation Jump to search

Pre-Submittal Meeting for License Amendment Requests to Implement Batch Framatome 15 X 15 AGORA-5A-I (Agora) Fuel at Surry Power Station Units 1 and 2 (SPS) - Slides
ML20309A591
Person / Time
Site: Surry  Dominion icon.png
Issue date: 10/14/2020
From:
Dominion Energy Virginia
To: Vaughn Thomas
NRC/NRR/DORL/LPL2-1
Thomas V
Shared Package
ML20309A667 List:
References
Download: ML20309A591 (13)


Text

Pre-Submittal Meeting for License Amendment Requests to Implement Batch Framatome 15x15 AGORA-5A-I (AGORA) Fuel at Surry Power Station Units 1 & 2 (SPS)

October 14, 2020 1

Agenda

  • Introductions and Overview of Agenda
  • Impetus for Fuel Transition
  • Submittal Strategy
  • Scope and Content for DDL LAR
  • Scope and Content for AGORA VQP LAR
  • Proposed Schedule 2

Dominion Energy AGORA Project Team

  • Gary Miller Regulatory Affairs - SPS
  • Dan Smith Fuel Procurement Project Manager
  • Scott Luchau Supervisor, Nuclear Safety Analysis
  • Chris Clemens Supervisor, Fuel Procurement Engineering
  • Thu Ho Nuclear Safety Analysis
  • Nawal Valliani Nuclear Safety Analysis
  • Nadine Shane Nuclear Safety Analysis
  • Brian Mount Nuclear Safety Analysis 3

Impetus for Fuel Transition

  • Dominion Energy seeks to resolve two issues with the proposed transition to AGORA Fuel
  • AGORA M5tm cladding has lower hydrogen uptake improving performance under accident conditions
  • AGORA fuel product will provide Dominion Energy greater security of supply and commercial competitiveness 4

Submittal Strategy

1) Submit for approval of new Appendix E to Generic Fleet Report DOM-NAF-2-P-A containing qualification of VIPRE-D/BWU-I code/correlation pair and its associated Deterministic Design Limit (DDL)
  • Scheduled for Mid-November 2020
2) Submit for approval batch implementation of AGORA VQP
  • Scheduled for End Q1 2021
3) Submit for approval SPS Spent Fuel Pool Criticality Analysis
  • Scheduled for End Q2 2021
  • Updated Dominion methodology, increase enrichment limit, include Gadolinia in Licensing Basis (required for AGORA) 5

DDL LAR LAR is expected to contain three attachments:

1) Appendix E to DOM-NAF-2-P, Qualification of the Framatome BWU-I CHF Correlation in the Dominion Energy VIPRE-D Computer Code
  • Description of Framatome BWU-I CHF Correlation and VIPRE-D/BWU-I Database & Test Assemblies
  • VIPRE-D/BWU-I Benchmarking & Qualification Results
2) Appendix E to DOM-NAF-2-NP, Qualification of the Framatome BWU-I CHF Correlation in the Dominion Energy VIPRE-D Computer Code
  • Description of Framatome BWU-I CHF Correlation and VIPRE-D/BWU-I Database & Test Assemblies
  • VIPRE-D/BWU-I Benchmarking & Qualification Results
3) Framatome Affidavit 6

AGORA VQP LAR LAR is expected to contain twelve attachments:

1) Discussion of Technical Specifications Changes
  • Dominion Energy DOM-NAF-2 Appendix E
  • Framatome Thermo-Mechanical Performance Methodology
2) Proposed TS Pages (Mark-Up)
3) Proposed TS Pages (Typed) 7

AGORA VQP LAR LAR is expected to contain twelve attachments:

4) 50.46 and Appendix K Exemption for M5 Cladding
  • Approval of M5 fuel rod cladding
5) Technical Basis for Adding Appendix E of Fleet Report DOM-NAF-2 to the COLR list of methodologies
  • Approval of the Statistical Design Limit (SDL) application for SPS with the AGORA fuel with the BWU-I and BWU-N correlations SDL
6) Mixed Core DNB Penalty Calculation 8

AGORA VQP LAR LAR is expected to contain twelve attachments:

7) ANP-3649P Surry Units 1 & 2 License Amendment Request Inputs for Use of Framatome Fuel
  • Fuel Assembly Design Description
  • Mechanical Design Evaluation
8) ANP-3649NP Surry Units 1 & 2 License Amendment Request Inputs for Use of Framatome Fuel
9) Framatome Affidavit for ANP-3649 9

AGORA VQP LAR LAR is expected to contain twelve attachments:

10) ANP-3669P Surry Units 1 and 2 Realistic Large Break LOCA Summary Report
11) ANP-3669NP Surry Units 1 and 2 Realistic Large Break LOCA Summary Report
12) Framatome Affidavit for ANP-3669 10

Proposed Schedule Dominion Milestones For AGORA VQP Implementation 11

Discussion 12

Acronyms AGORA Framatome 15x15 AGORA 5A-I Fuel CFR Code of Federal Regulations CHF Critical Heat Flux COLR Core Operating Limits Report DDL Deterministic Design Limit DNB Departure from Nucleate Boiling LAR License Amendment Request LOCA Loss of Coolant Accident NRC Nuclear Regulatory Commission SDL Statistical Design Limit SPS Surry Power Station TS Technical Specifications VQP Vendor Qualification Program 13