UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 November 6, 2020 MEMORANDUM TO: Anthony Dimitriadis, Chief Decommissioning, ISFSI and Reactor HP Branch Division of Nuclear Materials Safety Region I Binoy Desai, Chief Engineering Branch 3 Division of Reactor Safety Region II Steve Orth, Chief Plant Support Branch Division of Reactor Safety Region III Greg Warnick, Chief Reactor Inspection Branch Divison of Nuclear Materials Safety Region IV FROM:
Kevin Hsueh, Chief /RA/
Radiation Protection and Consequence Branch Division of Risk Assessment Office of Nuclear Reactor Regulation
SUBJECT:
THREE-YEAR COLLECTIVE TOTAL EFFECTIVE DOSE EQUIVALENT PER REACTOR-YEAR FOR 2017-2019 MONITORING YEARS is provided for your use in planning inspections and dispositioning inspection findings. The Nuclear Regulatory Commissions (NRC) Inspection Manual contains references to Three Year Rolling Average (TYRA) collective dose in the resource estimate section of Inspection Procedure (IP) 71124.02, Occupational ALARA Planning and Controls, dated January 1, 2020, and in Section IV of Inspection Manual Chaper (IMC) 0609, Appendix C, Public Radiation Safety Significance Determination Process, dated August 19, 2008.
CONTACT:
David Garmon (301) 415-3512 IP 71124.02 directs inspection resources to be applied using a graded approach based on plant ranking by TYRA collective dose. The plants in the first quartile are usually assigned the lowest number of inspection hours, whereas the plants in the fourth quartile are usually assigned the highest number of inspection hours. Plants in the middle two quartiles typically receive the average number of inspection hours allowed by IP 71124.02. However, NRC inspection staff is allowed to adjust inspection hours as necessary to fulfill the objectives of the IP.
When dispositioning performance deficiencies in the As Low As is Reasonably Achievable (ALARA) area, IMC 0609, Appendix C directs NRC staff to consider a licensees overall performance in maintaining occupational doses ALARA. This consideration is intended to direct potential NRC follow-on inspection resources, that would result from greater than Green inspection findings, to those programs with the largest challenges. The TYRA collective dose is a high level indication of the radiological challenges encountered by an ALARA program.
Power reactor licensees are included as one of the seven categories of NRC licensees that are required by 10 CFR 20.2206 to report the results of individual monitoring that is required by 10 CFR 20.1502. Licensees may voluntarily include additional data for individuals for whom monitoring was provided but not required. The data provided in Enclosure 1 was extracted from the Radiation Exposure Information and Reporting System (REIRS)the system the NRC uses to collect and store occupational exposure data. The TYRA is determined by summing the collective dose per reactor for the current year and the previous 2 years and then dividing this sum by 3, which is the number of years considered.
ML20304A145 OFFICE NRR/DRA/ARCB BC: RES/DSA/RPB BC: NRR/DRA/ARCB NAME DGarmon JTomon KHsueh DATE 10/29/2020 11/03/2020 11/06/2020
THREE-YEAR COLLECTIVE TOTAL EFFECTIVE DOSE EQUIVALENT PER REACTOR-YEAR FOR BOILING AND PRESSURIZED WATER REACTORS 2017-2019 ENCLOSURE 1 THREE-YEAR COLLECTIVE TOTAL EFFECTIVE DOSE EQUIVALENT PER REACTOR-YEAR FOR BOILING AND PRESSURIZED WATER REACTORS 2017-2019