THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-9 4.2.1.2 1/3.5 Scale Test

1) Objectives The ACC design uses an anti-vortex cap at the top of the standpipe to prevent the formation of a vortex as the flow drains from the tank such that the flow will only switch from a high flow to a lower flow when the level in the ACC drops below the top of the standpipe.

Without the anti-vortex cap it is possible for supercritical flow to form at the standpipe inlet as the water level approaches the top of the standpipe. Under these conditions and gas could be entrained, and the flow rate would not switch smoothly. The purpose of these experiments was to demonstrate that the inclusion of the anti-vortex cap will promote smooth flow switching as the tank water level decreases.

The test was conducted to confirm the flow behavior and potential for vortex formation in the ACC and to confirm the effect of the anti-vortex cap.

2) Test Apparatus The outline drawing of the test facility is shown in Fig. 4.2.1.2-1. The test apparatus consists of the standpipe, test tank, pump, and piping. The anti-vortex cap that is installed at the top of the standpipe was made of transparent acrylate such that the flow can be observed at the standpipe inlet. The scale of the standpipe inlet is 1/3.5 of the actual standpipe design.

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-10 Fig. 4.2.1.2-1 Outline Drawing of 1/3.5 Scale Test Apparatus MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-11

3) Testing Method (1) The experiment was scaled using the Froude Number as the basis since there was an open tank with a fluid surface. The relationship between the model tank (m) and the actual accumulator (p) is given below assuming the Froude Number is defined as

5.0 L

g V

Fr

(4-1)

And m

p Fr Fr (4-2) m m

p p

Q L

L Q

5.2 (4-3) m m

p p

V L

L V

5.0 (4-4) m m

p p

t L

L t

5.0 (4-5) where Fr Froude number L

Typical dimension Q

Typical flow rate V

Typical velocity t

Time p

Subscript denoting the actual ACC m

Subscript denoting the 1/3.5 scale model (2) The flow rate was measured by an ultrasonic flow meter and the tank water level was measured by the level marking on the sidewall of the tank.

4) Test Conditions The test conditions are shown in Table 4.2.1.2-1. Two types of standpipe inlet (with the anti-vortex cap and without it) were tested. The tests were performed using two flow rates in which the test and actual ACC Froude numbers were preserved. The flow rates were

[ ] and [ ]. These cover the expected flow rates at flow switching for minimum and maximum initial gas pressures, respectively. The injection characteristics with test flow rates are shown in Figs. 4.2.1.2-2 to 4.2.1.2-5.

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-12 Table 4.2.1.2-1 Test Conditions Test Number Test Condition Remarks Corresponding Actual Condition Anti-vortex Cap Flow Characteristics Flow Rate just before switching (gpm (l/sec))

Froude number is preserved.

Initial Gas Pressure (psig (MPa(g)))

Flow Rate just before switching (gpm (m 3/h))

1-1 No Fig. 4.2.1.2-2

[ ]

[ ]

[ ]

[ ]

1-2 Yes Fig. 4.2.1.2-3

[ ]

2-1 No Fig. 4.2.1.2-4

[ ]

[ ]

[ ]

[ ]

2-2 Yes Fig. 4.2.1.2-5

[ ]

5) Parameters and Measuring Equipment Flow rate and water level were measured to confirm the conditions during flow switching.

The flow rate was measured using an ultrasonic flow meter and the tank water level was measured by the level markings on the sidewall of the tank.

6) Test Results and Consideration Test results are summarized in Table 4.2.1.2-2. The flow at the inlet for various conditions is shown in Photos. 4.2.1.2-1(1/2), (2/2) through 4.2.1.2-2(1/2), (2/2). The following observations were made during the test.

(1) In the case of the standpipe inlet without the anti-vortex cap, a slight surface dimple appeared above the inlet and the initiation of supercritical flow developed when the water level began to decrease. When the water level decreased further, the supercritical flow condition was apparent and the surface dimple reached into the standpipe, and gas entrainment occurred. (Photo. 4.2.1.2-1(1/2), (2/2))

(2) Below the water level where the supercritical flow condition becomes apparent, the critical depth became smaller consistent with the water level reduction. This resulted in a lower flow rate and a slower reduction of the water level.

(3) The condition described in (2) above is apparent in the wave pattern. For example, in Fig.

4.2.1.2-2, supercritical flow was apparent, gas entrainment started 26 seconds after initiation of the test, and the variation of the flow rate became lager. As the flow rate became smaller, it took as long as 5 seconds before the flow rate into the standpipe became zero.

(4) This qualitative condition appeared in the case of both the minimum initial gas pressure of

[ ] and the maximum initial gas pressure of [

] without any significant differences.

(5) In the case of the standpipe inlet with the anti-vortex cap, a slight disturbance appeared on the water surface as the water level decreased from just above the upper end of the cap to the lower end of the cap. However, neither a vortex nor a supercritical flow occurred, and the flow rate switched sharply over a short period of time. (Photos.

4.2.1.2-2(1/2), (2/2))

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-13 This condition is apparent in the wave pattern. For example, in Fig. 4.2.1.2-3, the flow rate into the standpipe became zero in approximately 1 second. The flow rate switched much more quickly than the case without the anti-vortex cap (which was approximately 5 seconds in Fig. 4.2.1.2-2).

(6) Based on the data and visual observations described above, the desired effects of the anti-vortex cap were confirmed.

Table 4.2.1.2-2 Summary of Test Results Test Number (T. No)

Test Condition Test Results Flow Characteristics Anti-vortex Cap Vortex Formation Time to finishing switching (sec)

Remark 1-1 Fig. 4.2.1.2-2 No Yes Approx. 5 Photo. 4.2.1.2-1 (1/2), (2/2) 1-2 Fig. 4.2.1.2-3 Yes No Approx. 1 Photo. 4.2.1.2-2 (1/2), (2/2) 2-1 Fig. 4.2.1.2-4 No Yes

[ ]

2-2 Fig. 4.2.1.2-5 Yes No

[ ]

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-14 Photo. 4.2.1.2-1 (1/2) Visualization of Flow without Anti-Vortex Cap (T. No. 1-1) 1/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-15 Photo. 4.2.1.2-1 (2/2) Visualization of Flow without Anti-Vortex Cap (T. No. 1-1) 2/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-16 Photo. 4.2.1.2-2 (1/2) Visualization of Flow with Anti-Vortex Cap (T. No. 1-2) 1/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-17 Photo. 4.2.1.2-2(2/2) Visualization of Flow with Anti-Vortex Cap (T. No. 1-2) 2/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-18 Fig. 4.2.1.2-2 Test Flow Characteristics without Anti-Vortex Cap (T. No. 1-1)

Flow rate Large flow rate range Initiation of supercritical flow (Gas entrainment occurs)

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-19 Fig. 4.2.1.2-3 Test Flow Characteristics with Anti-Vortex Cap (T. No. 1-2)

Flow rate Large flow rate range Initiation of flow switching MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-20 Fig. 4.2.1.2-4 Test Flow Characteristics without Anti-Vortex Cap (T. No. 2-1)

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-21 Fig. 4.2.1.2-5 Test Flow Characteristics with Anti-Vortex Cap (T. No. 2-2)

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-22 4.2.1.3 1/5-Scale Test

1) Objectives The objective of 1/5-scale test was to observe the flow in the flow damper during large and small flow, large to small flow switching, and to confirm the expected behavior of the flow.

(Note)

The 1/5-scale test was performed without the equalizing pipe. This is because the equalizing pipe does not affect the operational principle because it is not directly related to any operational function such as direct flow to the outlet during large flow injection, sharp flow switching, or strong vortex formation during small flow injection.

2) Test Apparatus The outline drawing of the test apparatus is shown in Fig. 4.2.1.3-1. The test facility consists of a test tank, flow damper, standpipe, injection piping, and exhaust tank. The flow damper is made of transparent acrylate to allow the fluid characteristics in the flow damper to be observed. A ball valve (nominal diameter is [ ]) is provided in the injection line as the isolation valve and a gate valve (nominal diameter is [ ]) is also provided in the injection line to control the flow resistance.

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-23 Fig. 4.2.1.3-1 Outline Drawing of the Visualization Test Apparatus MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-24 The specifications of the test facility are as follows:

(1) Test tank Design Pressure

[ ]

Diameter

[ ]

Height

[ ]

Volume

[ ]

(2) Flow damper and standpipe (1/5-scale actual size)

Diameter of vortex chamber

[ ]

Height of vortex chamber

[ ]

Shape of standpipe

[

]

(3) Injection piping Inner diameter

[ ]

(Simulating the pressure drop)

(4) Exhaust tank Design Pressure

[ ]

Diameter

[ ]

Height

[ ]

Volume

[ ]

3) Testing Method (1) Visualization tests were conducted for three cases: (i) examining flow characteristics during large flow injection and flow switching by setting the initial pressure at

[ ], which is the maximum design pressure of the test tank; (ii) examining flow characteristics during small flow injection by setting the initial pressure at [ ] for an extended small flow injection time, and (iii) examining flow characteristics during flow switching by setting the initial pressure at

[ ], which has the same Froude number as that of the actual plant condition.

(2) The flow characteristics in the flow damper were recorded and observed using a video camera, as shown in Fig. 4.2.1.3-1.

(3) The characteristics of the flow in the vortex chamber were observed using blue ink as a flow tracer.

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-25

4) Test Conditions Visualization test conditions are shown in Table 4.2.1.3-1.

Table 4.2.1.3-1 Visualization Test Conditions MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-26

5) Parameters and Measuring Equipment Pressure, water level, and temperature were measured to calculate cavitation factors and flow rate coefficients. The differential pressure transducer for measuring water level in the tank and the attachments for the pressure transducer are shown in Fig. 4.2.1.3-1.
6) Test Results and Consideration The visualization test results are summarized in Table 4.2.1.3-2 and the flow in the vortex chamber during large flow, large/small flow switching, and small flow are shown in Photos.

4.2.1.3-1 to 4.2.1.3-3. The white lines are added in the photos to clearly show the tracer trajectories.

(1) The characteristics of the large flow are shown in Photo. 4.2.1.3-1. Since the flow tracer traveled from the point of the flow from the standpipe directly to the flow damper exit following collision with the water from the small flow inlet, it was confirmed that a vortex was not formed in the vortex chamber during large flow injection.

(2) The characteristics of the large / small flow switching are shown in Photo. 4.2.1.3-2. It shows the beginning of the formation of a vortex during flow rate switching. It was also confirmed that gas entrainment from the standpipe did not occur and the flow rate switched smoothly in a short time.

(3) The characteristics of small flow are shown in Photo. 4.2.1.3-3. It was confirmed that the flow tracer swirled to the outlet, and a stable vortex was formed in the vortex chamber.

No cavitation was observed at the center of the vortex.

Table 4.2.1.3-2 Visualization Test Results Test Number (T. No.)

Initial Pressure (Test Tank)

Large Flow Flow Rate Switching Small Flow 1/5-1

[ ]

[ ]

A vortex was not formed in the vortex chamber during large flow.

The flow rate switched smoothly in a short time.

1/5-2

[ ]

[ ]

A stable vortex was formed in the vortex chamber.

1/5-3

[ ]

[ ]

The flow rate switched smoothly in a short time.

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.1-27 Photo. 4.2.1.3-1 Large Flow Photo. 4.2.1.3-2 Switching Flow Rate Photo. 4.2.1.3-3 Small Flow MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-1 4.2.2 Qualification Testing

1) Objectives (1) Verification of performance during large flow and small flow phases:

Tests were conducted to confirm that the performance of the flow damper, during large flow and small flow respectively, met the acceptance criteria (resistance coefficient for large and small flow injection).

(2) Verification of the flow switching without need of any moving parts:

It was assumed that the injection flow rate shifts from large flow to small flow when the tank water level decreases to the lower edge of the standpipe anti-vortex cap. This design feature was verified by actual injection testing.

(3) Confirmation of the effect of dissolved nitrogen gas:

Since the accumulator utilizes compressed nitrogen gas, nitrogen gas may dissolve in the water. If the water in the accumulator contains dissolved nitrogen gas, it is assumed that the gas comes out of solution and affects the flow characteristics of the flow damper.

Therefore, tests were conducted with nitrogen-rich water to confirm that the effect of nitrogen gas did not impact the ACC performance.

2) Test Facility The schematic and outline drawing of the test facility and the general flow path are shown in Fig. 4.2.2-1 and Fig. 4.2.2-2. The test facility consists of a test tank, flow damper, injection piping, and exhaust tank. The flow damper is installed in the test tank. The test tank and the flow damper are full-scale. A ball valve is provided in the injection line as the isolation valve and a gate valve is provided in the injection line to control flow resistance. A pressure control valve is provided on the upper side of the exhaust tank to control the tank pressure during the test.

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-2 Fig. 4.2.2-1 Schematic Drawing of the Full-Scale Test Facility P

L P

L Accumulator (Full-Scale Test Tank)

Flow Damper Flow Control Valve Isolation Valve Exhaust Tank P

T T

PC Supply Equipment Silencer Nitrogen Tank PC P

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-3 Fig. 4.2.2-2 Outline Drawing of the Full-Scale Test Facility MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-4

3) Test Conditions MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-5 Table 4.2.2-1 Test Conditions of Full-Scale Test MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-6

4) Parameters and Measuring Equipment
5) Acceptance Criteria MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-7

6) Test Results and Conditions MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-8 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-9 Table 4.2.2-2 Flow Switching Water Level

7) Quality Assurance MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-10 Fig. 4.2.2-3 (1/2) Full-Scale Test Results (Case 1) 1/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-11 Fig. 4.2.2-3 (2/2) Full-Scale Test Results (Case 1) 2/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-12 Fig. 4.2.2-4 (1/2) Full -Scale Test Results (Case 2) 1/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-13 Fig. 4.2.2-4 (2/2) Full-Scale Test Results (Case 2) 2/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-14 Fig. 4.2.2-5 (1/2) Full-Scale Test Results (Case 3) 1/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-15 Fig. 4.2.2-5(2/2) Full-Scale Test Results (Case 3) 2/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-16 Fig. 4.2.2-6 (1/2) Full-Scale Test Results (Case 4) 1/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-17 Fig. 4.2.2-6 (2/2) Full-Scale Test Results (Case 4) 2/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-18 Fig. 4.2.2-7 (1/2) Full-Scale Test Results (Case 5) 1/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-19 Fig. 4.2.2-7 (2/2) Full-Scale Test Results (Case 5) 2/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-20 Fig. 4.2.2-8 (1/2) Full-Scale Test Results (Case 6) 1/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-21 Fig. 4.2.2-8 (2/2) Full-Scale Test Results (Case 6) 2/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-22 Fig. 4.2.2-9(1/2) Full-Scale Test Results (Case 7) 1/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

4.2.2-23 Fig. 4.2.2-9(2/2) Full-Scale Test Results (Case 7) 2/2 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

5-1 5.0 CONCEPT OF THE SAFETY ANALYSIS MODEL Section 5 describes how to apply the hydraulic performance measured from the full-scale test results to the safety analysis. The accumulator flow rate is modeled in the safety analyses through parameters such as the characteristic equations of the flow damper and its uncertainty, uncertainty of flow rate switching, and the effect of dissolved nitrogen. According to the methodologies outlined below, these parameters are treated appropriately in the safety analyses.

5.1 Flow Rate Characteristics for Safety Analysis Subsection 5.1 discusses characteristic equations for accumulator flow rates and its uncertainties used in the safety analysis.

5.1.1 Characteristic Equations of Flow Rates for the Safety Analysis MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

5-2 Fig. 5.1-1 The Flow Characteristics of the Flow Damper MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

5-3 5.1.2 Estimation of Uncertainty of the Characteristic Equations of Flow Rates MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

5-4 Table 5.1-1 Dispersion of the Data from the Experimental Equations MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

5-5 Table 5.1-2 Instrument Uncertainties MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

5-6 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

5-7 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

5-8 Table 5.1-3 Total Uncertainty of Flow Rate Coefficient (Experimental Equations) for Safety Analysis of US-APWR MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

5-9 5.2 Estimation of Potential Uncertainties of Water Level for Switching Flow Rates MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

5-10 Table 5.2-1 Uncertainty of Water Level for Switching Flow Rates MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

5-11 5.3 Treatment of Dissolved Nitrogen Gas Effect in the Safety Analysis MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

5-12 5.4 LOCA Analytical Model and Computational Procedure for Characteristic Equations MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

5-13 MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

6-1 6.0 CHARACTERISTIC EQUATIONS IN THE PRE-OPERATIONAL TEST MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

7-1 7.0

SUMMARY

The Mitsubishi Heavy Industries, Ltd. Advanced Accumulator (ACC) design will be used in MHIs Advanced Pressurized Water Reactors. The ACC design simplifies the emergency core cooling system design by integrating the short term large flow rate design requirements currently satisfied in conventional pressurized water reactor designs by the combined injection capabilities of the primary system accumulator and the low head safety injection pump into a single passive device, the ACC.

The ACC is a borated water storage tank with a fluidic device that throttles the flow rate of cooling water injected into a reactor vessel from a large to a small flow rate. A conceptual drawing of the ACC is shown below.

The vortex chamber at the inlet of the injection pipe in the accumulator accomplishes the flow rate throttling from large flow to small flow by establishing a vortex (and thus a large pressure drop) at a predetermined accumulator level. The inlet of the standpipe is located at the ACC volume level at which the transition from large to small flow is desired to occur. The ACC is a simple device that achieves precise throttling from a large injection flow rate to a small injection flow rate with no moving parts.

Upon initiation of a large break loss of coolant accident, all short term low head primary coolant injection flow requirements are satisfied by the ACC. Following depletion of the ACC water volume, the long-term ECCS flow requirements are met by the high-head safety injection pumps thus eliminating the need for low head safety injection pumps. The immediate availability of low head flow provided by the ACC upon loss of electrical power coincident with a large break loss of coolant accident provides additional time for actuation of the backup emergency power source.

Large Flow (RV Refilling)

Water Levels in Accumulator Tank Small Flow (Core Reflooding)

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

7-2 The confirmatory and qualification test programs were successfully conducted. The confirmatory tests confirmed the principles of operation of the flow damper. And, the qualification testing verified that:

1. The performance of the flow damper, during large flow and small flow respectively, met the acceptance criteria (resistance coefficient for large and small flow injection)
2. Sharp flow rate switching occurred without significant gas entrainment.

Empirical flow rate coefficients have been developed from the test results and will be used in an integrated thermal hydraulic model of the US-APWR Reactor Coolant and ECCS to assure the US-APWR meets or exceeds all US safety standards.

The ACC design is expected to improve the safety of pressurized water reactors by the innovative application of the flow damper to assure the early stage of LOCA injection flow is satisfied by an inherently reliable passive system. This innovation reduces the necessity of relying on maintenance sensitive components such as low head safety injection pumps for assuring LOCA injection flow, provides additional time for actuation of backup emergency power for loss of power coincident with a large break LOCA, and reduces the net maintenance and testing burden by the elimination of low head safety injection pumps from the LOCA mitigation strategy.

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

8-1

8.0 REFERENCES

4.3-1 S.S. Fineblum, Vortex Diodes, pp. 48-80, Proceedings of the Fluidic State-of-the-art Symposium Held at Naval Ordnance Laboratory, White Oak, Maryland on 30 September - 3 October, 1974.

4.3-2 J. W. Stairmand, Flow patterns in vortex chambers for nuclear duties, Vol. 29, No. 6, pp. 413-418, Nucl. Energy, Dec., 1990 5-1 Mitsubishi Heavy Industries, Ltd., Large Break LOCA Code Applicability Report for US-APWR, MUAP-07011-P 5-2 Mitsubishi Heavy Industries, Ltd., Small Break LOCA Methodology for US-APWR, MUAP-07013-P 5-3 ISO/IEC Guide 98-3: 2008 Uncertainty of measurement - Part 3, Guide to the expression of uncertainty in measurement (GUM: 1995)

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

A-1 Appendix A Studies on Vortex Behaviors in Flow Diodes Flow in vortex diodes is similar to flow in the vortex chamber of the flow damper for small flow injection. Papers with regard to vortex diodes are useful to investigate the vortex behaviors for small flow injection in the vortex chamber of the flow damper. J. W. Stairmand described the flow patterns and dominant mechanisms in a vortex chamber (Ref. 4.3-2). S. S. Fineblum reported his excellent experimental results on various geometries of vortex diodes in 1974 (Ref.

4.3-1). This section provides the summaries of these reports.

1. Summary of Qualitative Investigation J.W. Stairmand indicated that the dominant mechanism for flow in a vortex chamber is the conservation of angular momentum. In other words, he notes that the dominant mechanism for flow in a vortex chamber is the conservation of circulation. The flow pattern in a vortex chamber consists of a free vortex region in the periphery where the circulation is conserved and a forced vortex region in the central part where a significant pressure drop occurs.

Therefore in the design of fluidic devices, it is important to clarify at what point the transition from free to forced vortex occurs. Stairmand used the model that was first applied to the vortex valve by Wormley. This model assumes axisymmetry and uses the momentum integral method of solving the boundary layer equations. This identifies a developing flow region (r > rc) and a developed flow region (r < rc). In the developing flow region, the circulation is conserved; in the developed flow region, flow is restricted by the boundary layer and the circulation is not conserved. Predictions for the distribution of swirl velocity in the vortex chamber exhibit a variety of forms to characterize the free and forced vortex modes. A modified boundary layer coefficient (BLC*) as shown below, was found to largely determine which form is taken.

25 0

2 Re*

AfS BLC where

i i

i v

w S

h v

Re h

R A

2 f :

Friction factor for flow over the equivalent flat plate Re* :

Reynolds number A :

Aspect ratio between the radius of the vortex chamber R and the height of the vortex chamber h Kinematic viscosity S :

Swirl number in the vortex chamber iv :

The value of the radial velocity v at R

r i

w :

The value of the tangential velocity w at R

r Wormley's theory has been used to predict the circulation distribution shown in dimensionless form in Fig. A-1. From this diagram it is clear that when BLC* is 0.25 or less, the flow in the vortex chamber conserves circulation. When BLC* is greater than 0.25, the MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

A-2 flow structure changes to a forced vortex at some critical radius. As BLC* is increased, the extent of this central forced vortex increases until it occupies most of the vortex chamber (BLC* = 2).

The pressure profiles across the chamber are shown in dimensionless form in Fig. A-2. For BLC* less than 1, the pressure profiles are substantially determined by inertial effects and an inviscid analysis is appropriate. Thus it seems that the viscosity effect is weak when BLC* is 1 or less.

Fig. A-1 Calculated circulation distribution (Ref 4.3-2)

Fig.A-2 Calculated pressure profile (Ref 4.3-2)

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

A-3

2. Summary of Quantitative Investigations
1) Experiments The vortex chambers used in his experiments varied in diameter, D, from 1.58 to 3.25 inches (40 to 82.6 mm) and in length, L, (equivalent to height of the vortex chamber, H, for the ACC) from 0.188 to 1.0 inches (4.78 to 25.4 mm). The nozzles varied in width from 0.016 to 0.4275 inches (0.4 to 11.1 mm), and the outlet varied in diameter from 0.179 to 0.394 inches (4.6 to 10.0 mm). The maximum available pressure, p, and flow, Q, were 100 psi (6.90x105 N/m2) and 6 gpm (3.79x10-4 m3/sec). It is not clearly mentioned in the paper, but gas or air appeared to be the working fluid because of the large tangential velocities of the diodes. If the working fluid was air at 305 K in temperature, the maximum dimensionless flow rate (equivalent to Reynolds number)

)

H

(

Q q*

2

, is from 82 to 440. is the kinematic viscosity of the fluid.

2) Vortex Pressure Drop Coefficient The pressure drop coefficient K is defined as:

n N

i o

R n

V P

P K

2 2

1 1

2

where R is the ratio of the outer-to-inner radii of vortex diodes, R=ri/ro, ri the radius of the vortex chamber, ro the radius of the outlet port, and n the vortex exponent. The exponent, n, varies between -1 (forced vortex) and 1 (free vortex).

The tangential velocity, V, at an arbitral radius, r, is assumed to have the form:

n i

N r

r V

V

where VN is the tangential velocity from the nozzle.

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

A-4 Fig. A-3 Test Results: Total Pressure Drop Coefficient across Diode Versus Radius Ratio (Ref. 4.3-1)

The variation of the pressure drop coefficient, K, with respect to the ratio of radii, R, is shown in Fig. A-3. Lines of computed K versus R with constant values n are plotted for comparison.

The results of Fineblum show that for most vortex chambers the effective vortex exponent is approximately constant. The vortex exponent, n, should be chosen as an effective n to express the fact that many modes of flow in the vortex chamber result in a specific pressure drop and that the resulting pressure drop coefficient is a function of R. Therefore, n is an average correlation quantity rather than a true vortex exponent indicating the exact mode of vortex flow. The real flow in the vortex chamber is three dimensional due to the growth of boundary layers on the walls, which cannot be expressed by Eq. (2). Therefore, the vortex exponent "n" cannot be theoretically determined, but has to be experimentally determined.

3) Effect of Height-to-Diameter Ratio For very thin diodes the boundary layers on its disk walls will completely fill the chamber. As the height increases, the available distance free of the boundary layers increases. Once this free distance is much greater than the boundary layer, further increase in L/D is not beneficial.

The average vortex exponent, n, increases with L/D as seen in Fig.A-4. It supports the fact mentioned above. In the cases of the vortex diodes, the vortex exponent, n, becomes relatively insensitive to any increase above L/D=0.35. The insensitivity limit must depend on viscosity. If viscosity effect is smaller, thickness of the boundary layer on the wall in the vortex chamber must be thinner to give a smaller insensitivity L/D limit.

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

A-5 Fig. A-4 Variation of Vortex Exponent, n, with respect to Ratio of Vortex Height to Diameter (Ref. 4.3-1)

4) Vortex Generated Pressure Drop in Outlet Tube Fineblum stated that, "In most cases, the pressure drop measured across the outlet tube was relatively insignificant. However, at very high values of vortex radius ratio and vortex pressure drop coefficient, the pressure drop through the outlet tube is a major portion of the total." In this case, the pressure drop in the tube immediately downstream of the vortex chamber contributes significantly to the vortex generated pressure drop. It is important to note that the swirl flow in the outlet tube originates in the vortex chamber. This means that the pressure loss from swirl flow in the outlet tube is controlled by the vortex in the vortex chamber. Strictly speaking, the dynamic pressure converted from static pressure in the vortex chamber is lost in the outlet tube, if there is no static pressure recovery.

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

B-1 Appendix B Explanation about updates from rev.5 This appendix provides explanation about the basis for the design modification (installation of equalizing pipe), summary of updates based on the design modification, and explanation about each updates from revision 5 this report.

1. Basis for the design modification During full-scale testing, unstable flow during the large flow injection phase was sometimes observed. It was determined that this was due to swirl flow in the vortex chamber that was being caused by uneven pressure across the vortex chamber.

In order to eliminate any unstable flow, it is necessary to prevent swirl flow in the vortex chamber during the large flow rate injection phase. An effective method to prevent swirl flow is to equalize the pressure across the vortex chamber.

Therefore, it was determined to install an equalizing pipe across the vortex chamber.

2. Summary of topical report update based on the design modification After revision 6 of this report incorporates the design modification (installation of equalizing pipe) and qualification tests results performed in a full-scale test facility.

Description about Full-Height 1/2-scale model test, low pressure injection test with 1/5-scale test and discussion regarding scalability were deleted, and full-scale qualification test results were added in of this report.

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

B-2

3. Explanation about each updates Location Explanation ABSTRACT Descriptions were updated incorporating the followings.

Change of the verification base to full-scale qualification test from scaled tests.

Deletion of 1/2-scale test, while 1/5-scale test was retained as a visualization test.

significant was added to precise description because gas entrainment, even such a slight quantity such that performance of the ACC was not influenced, is acceptable.

INTRODUCTION Descriptions were updated incorporating that the ACC design verification base was changed to full-scale qualification test from scaled tests.

Fig. 2.1-2 Editorial modification.(Legend for RCP is added) 2.2.2 Contents of Section 4.3.1 and 4.3.2 of revision 5 were moved to Section 2.2.2 because they contain detailed explanation of phenomenological features and effects on flow characteristics. While, scalability and CFD related descriptions were deleted because these are no longer necessary.

2.3.2

2)

Editorial modification. (Capitalized) 3.0 Title was changed. (as-installed was removed since it is not needed to clarify)

Fig. 3.2-1 Fig. 3.2-1 was revised to reflect the design modification (equalizing pipe installation).

3.3 Further descriptions about equalizing pipe were added.

Fig. 3.3-1 Fig. 3.3-1 was revised to reflect the design modification (equalizing pipe installation).

Fig. 3.3-2 Fig. 3.3-2 is revised to reflect the design modification (equalizing pipe installation).

Table 3.3-1 Item (1) much was added to precise description because gas entrainment, such a slight quantity that performance of the ACC was not influenced, is acceptable.

Table 3.3-1 Item (3) significant was added to precise description because gas entrainment, such a slight quantity that performance of the ACC was not influenced, is acceptable.

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

B-3 Location Explanation 4.0 Title was changed. (confirmatory was removed since this section describes both confirmatory and qualification testing)

Description about joint study was deleted since it was related to scaled tests and no longer necessary to describe in this report.

Description about scalability was deleted because it is no longer necessary.

4.1 Title was changed. (scale was removed since this section describes both scaled and full-scale testing)

Descriptions were changed as clarifying confirmatory tests conducted during development phase and qualification tests conducted to verify the design.

Confirmatory item (3) to (9) were deleted because these were related to scalability.

Description about qualification test was added as identifying two verification items and one confirmatory item.

Fig. 4.1-1 was deleted because of above mentioned reason.

4.2 Section structure is changed. 1/8.4, 1/3.5 and 1/5-scale test were included in 4.2.1 Confirmatory Testing.

Full Height 1/2-Scale Test is deleted as replaced by 4.2.2 Qualification Testing.

Table, Figure, Photo and Equation numbers were modified accordingly.

Fig 4.2.4-12, The test results of water level reduction during flow rate switching, was deleted because they were Full Height 1/2-Scale tests results.

Contents of Section 4.3.1 and 4.3.2 of revision 5 were moved to Section 2.2.2 because they contain detailed explanation of phenomenological features and effects on flow characteristics. The other part of Section 4.3 of revision 5 was deleted because these were no longer necessary since related to scalability and CFD.

Section 4.4 of revision 5, Quality Assurance of the ACC Test Program, was deleted because the contents of section 4.4 was related to scaled tests.

(Quality assurance of the full-scale qualification test was added on 4.2.2 7)

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

B-4 Location Explanation 4.2.1.3 Descriptions about 1/5-scale low pressure injection test were deleted because the purpose of 1/5-scale low pressure injection testing was to confirm that the flow characteristics could be represented by dimensionless numbers, and these dimensionless numbers do not depend on the scale.

These were no longer necessary since it was qualified by full-scale testing results.

Fig 4.2.2-1 Fig 4.2.2-2 Figures are changed to full-scale test facility.

Comparison of Full Height 1/2-Scale and actual tank is deleted.

4.2.2

3) Test Conditions Descriptions were modified precisely, while test condition itself was not changed from Full Height 1/2-Scale tests.

Table 4.2.2-1 Initial gas and water volume was changed to the full-scale tank values.

4.2.2

4) Parameters and Measuring Equipment Equations for the flow rate coefficient and cavitation factor were added.

Nitrogen term was added to describe precisely, although the significance of it was negligible.

4.2.2

5) Acceptance Criteria Acceptance criteria for qualification testing were added.

4.2.2

6) Test Results and Conditions Description about reproducibility was added because the reproducibility test results were also used for creation of characteristics equations and random error evaluations.

Descriptions, tables and figures were updated with full-scale test results satisfying the acceptance criteria.

4.2.2

7) Quality Assurance Description about quality assurance of the qualification test was added.

5.0 Description of 1/2-scale test and scaling effect was deleted.

The uncertainty evaluations were updated with full-scale test results.

5.1.1 Characteristics equations were updated with the full-scale qualification test results.

Fig. 5.1-1 The figure was updated with full-scale qualification test results.

5.1.2 The basis of error evaluation was changed to GUM ISO/IEC Guide 98-3 because the full-scale qualification test was performed according to the quality manual of MHI Research & Innovation Center which refers GUM ISO/IEC Guide 98-3 as standard guidance of uncertainty evaluation.

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

B-5 Location Explanation 5.1.2 (1)

Equation 5-4 was modified as considering reproducibility test results for each case.

Table 5.1-1 Case by case evaluation result was not described because comprehensive value is applied to safety analyses.

5.1.2 (2)

Descriptions related to ANSI/ASME PTC19.1 1985 were deleted because uncertainty evaluation was performed based on GUM ISO/IEC Guide 98-3.

Values were updated with the full-scale qualification test results.

Table 5.1-2 Instrument uncertainty evaluation results were described simply because comprehensive value is applied to safety analyses.

5.1.2 (4)

Descriptions were modified based on GUM ISO/IEC Guide 98-3 methodology.

Table 5.1-3 Values were updated with the full-scale qualification test results.

5.2 Values were updated with the full-scale qualification test results.

Table 5.2-1 Evaluation was changed from root mean square to addition of flow switching level deviation and instrument error to have conservative value.

5.3 2 seconds and related description of time delay by dissolved nitrogen was deleted since it is not directly used in safety analyses model.

Section 5.4in revision 5, Estimation of Scaling Effect for Characteristic Equations, was deleted since it is no longer necessary.

5.4 Section 5.5 in revision 5 was moved to Section 5.4.

Characteristics equations were modified based on the full-scale qualification test results.

6.0 Descriptions were changed because the basis was changed to full-scale qualification test and terms related to scalability were no longer necessary.

Characteristics equations were modified based on the full-scale qualification test results.

7.0 Description was modified based on the full-scale qualification test results.

Description about joint study was deleted since it was related to scaled tests and no longer necessary to describe in this report.

MUAP-07001-NP-A (R7)

THE ADVANCED ACCUMULATOR Mitsubishi Heavy Industries, LTD.

B-6 Location Explanation 8.0 Reference 4.3-1, 4.3-4 and 4.3-5 of revision 5 were deleted since these were related to scalability. And the others were renumbered accordingly.

Appendices This appendix was added as Appendix B.

, test data of Full Height 1/2 Scale Tests, was deleted.

, Flow Characteristics of Flow Damper with Full Height 1/2 Scale Tests results, was deleted.

MUAP-07001-NP-A (R7)