ML20249B009

From kanterella
Jump to navigation Jump to search
PNO-76-035:on 751013,oyster Samples Collected within 500 Ft of Millstone Plant Discharge Exhibited Concentrations Greater than 10 Times Concentrations Observed at Control Station
ML20249B009
Person / Time
Site: Millstone 
Issue date: 03/04/1976
From: Dreher F, Roy G, Thompson D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To:
References
PNO-76-035-01, PNO-76-35-1, NUDOCS 9806190276
Download: ML20249B009 (1)


Text

Tj(){/ (2g&igrin/Q (fd W)*0 J W h V

PRELIMINARY NOTIFICATION '0F EVENT OR UNUSUAL DCCURRENCE --PNO-76-35 This preliminary notification constitutes EARLY notice of evente of POSSIBLE safety or public interest significance.

The information I

presented is as initially received without verification or evaluation and is basically all that is known by OIE staff as of 4:30 P.M. on date of this notification.

IT SHOULD BE SPECIFICALLY NOTED THAT THIS NOTIFICATION MAY CONTAIN INFORMATION THAT LATER MAY BE DETERMINED TO BE INACCURATE OR INCONSISTENT. AN OFFICE OF INSPECTION AND ENFORCEMENT NOTIFICATION OF AN INCIDENT OR OCCURRENCE (BLUE SHEET) SUBSEQUENTLY WILL BE ISSUED IF UARRANTED.

Facility:

Millstone Point 1 (DN 50-245)

)

Northeast Nuclear Energy Company l

i

Subject:

RADIOACTIVITY LEVELS IN THE ENVIRONMENT (See PNO-76-05 & PN-75-136)

I Oyster samples collected on October 13, 1975 within 500 feet of the Millstone Point discharge exhibited concentrations greater than 10 times the concentrations observed at the control station.

The concentrations are approximately the same as values previously reported by the licensee in routine Environmental Reports. However due to the special reporting requirements in Millstone l's recently effective Environmental Technical Specifications, a formal Non-Routine 10 day Report, after con-firmatory analysis, is now required for this situation.

The values in (pCi/g) were:

Mn-54 Co-60 Zn-65 Cs-134 Cs-137 Control Station

<0.03 0.03

<0.06

<.0.025 0.035 Near Discharge 1.8 4.4 2.8 1.0 0.93 Assuming 5 Kg/ year for a high average individual oyster intake, these concentrations in oysters would result in a dose to both the whole body and GI tract of approximately 1.1 mrem / year, which is about 1% of the dose due to natural background in this area.

g Media interest is possible in that the report is placed in the PDR and

/

Millstone has received considerable attention lately.

It is more likely

/

that this issue will receive attention when the annual report is submitted on or about April 1976 because of media, local, state and Congressional y{

interest. The State of Connecticut has been informed. A press release is not planned.

Region I, NRC, Philadelphia, Pa. received notification of this occurrence by letter from Northeast Nuclear Energy Company on 3/3/76.

Contact:

FADreher, IE x27261

GWRoy, IE x27261 DThompson, IE x27541' l

Distribution:

Chairman Anders Commissioner Mason S. J. Chilk, SECY Commissioner Gilinsky Commissioner Rowden G. F. Murphy, JCAE i

Commissioner Kennedy C. C. Kammerer, CA L. V. Gossick, J. G. Davis, OIE J. A. Harris, PA

3. C. Rusche, NRR J. La Fleur, ISP T.,J. McTiernan, AIA i

K. R. Chapman, NMSS H. K. Jhapar, ELD Transmitted:

P Bldg f.'38c H St f,'#.2a ; MNBBh.Y<;

Luge nc U' l

PRELIMINARY NOTT N M ON - NOT FOR PUBLIC DISCLOSURE

~

9906190276 760304 PDR 18 E rq PNO-76-035 PDR

_