PNO-78-036:on 771221,inspector Found That 3,000 Gallons Per Minute Flow Orifices Installed in Discharge Piping of Containment Rs Pumps,Instead of Specified 2,000 Gpm Flow Orifices
ML20248L116
Person / Time
Site: North Anna 
Issue date: 02/22/1978
From: Klingler G, Sniezek J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
PNO-78-036, PNO-78-36, NUDOCS 9806100439
Download: ML20248L116 (1)


Text

-tvR cu%a (jy fv 9pwp L1

.ayg b

{

PRELIMINARY NOTIFICATION February 22, 1978 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE -- PNO-78-36 This preliminary notification constitutes EARLY notice of an event of POSSIBLE safety or public interest significance.

The information presented is as initially received without verification or evaluation and is basically all that is known by IE staff as of this date.

FACILITY:

Virginia Electric and Power Company North Anna, Unit No.1 Docket No. 50-338 Louisa County, Virginia

SUBJECT:

INCORRECT FLOW ORIFICES INSTALLED IN RECIRCULATION SPRAY PIPING On December 21, an IE inspector found that 3000 gallons.per minute (gpm)

I flow orifices were installed in the discharge piping of containment recirculation spray (RS) pumps, instead of the specified 2000 gpm flow orifices (PNO-77-225 dated 12/22/77).

Orifices calculated to provide 2000 gpm flow were installed the same day.

The Architect Engineer, E

Stone and Webster (5&W), informed VEPC0 on February 17, that the speci-O fied 2000 gpm orifices were incorrectly sized initially, due to a mis-

[1

(

understanding between S&W and Bingham-Willamette, the pump vendor.

An error in application of the vendor's pump head curve introduced a 43-6 foot pump head error, resulting in the orifices being too small.

Pump

,P flow is estimated to be 1000 to 1500 gpm instead of the required 2000 o

gpm. The licensee expects to have the proper orifices installed about February 24.

Q Media interest is anticipated due to current interest in the North Anna facility.

A news release is not planned by the licensee nor NRC.

The Commonwealth of Virginia has been notified.

Region II (Atlanta) received initial notification of this occurrence by telephone from station management at 9:15 a.m. on February 21.

This information is current as of 11:30 a.m. on February 22.

Contact:

GKlingler, IE x28019 JSniezek, IE x28019 Distribution:

Transmitted H St 3lJ3-.

Chairman Hendrie Commissioner Bradford Commissioner Kennedy S. J. Chi'k, SECY C. C. Kammerer, CA Commissioner Gilinsky (For Distribution)

Transmitted:

MNBB 3!fY PBldg3/((

E. Volo u, IE L. V. Gossick, EDO E. G. Case, NRR Region 367 S. H. Hanauer, EDO J. J. Fouchard, PA 55 Bldg 3lf7 (MAIL)

R. Hartfield, MIPC C. V. Smith, NMSS T. J. McTiernan, 01 A R. G. Ryan, OSP R. Minogue, SD H k Shanar. ELD 9006100439 700222 RDR _I&E

-