l GPU Nuclear,Inc.
l
\\
U.S. Route 79 south l
NUCLEAR Post Office Box 388 Forked Rwer. NJ 08731-0388 Tel 609-9714000 (609) 971 4814 May 28, 1998 6L40-98-20080
(
U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington,DC 20555 Gentlemen:
Subject:
Oyster Creek Nuclear Generating Station (OCNGS)
Docket No. 50-219 Facility Operating License No. DPR-16 Technical Specification Change Request (TSCR) No. 254 Primary Containment Leakage Testing In accordance with 10 CFR 50.4(b)(1), please find enclosed Technical Specification Change Request (TSCR) No. 254.
GPU Nuclear requests that Technical Specification (TS) 4.5.A.1, contained in Appendix A of the Facility License, be revised such that the first Type A test required by the Primary Containment Leakage Rate Testing Program (established to meet Option B of 10 CFR 50 Appendix J) be performed during refueling outage 18R. Currently, TS 4.5.A.1 requires that the test be performed j
during refueling outage 17R. A summary of the proposed change is included as Attachment 1. The changed page is provided as Attachment 2.
/
As discussed with the NRC in our meeting on August 26,1997, GPU, Inc. has announced that in addition to continued operation, it was exploring the additional options of sale or early shutdown of the OCNGS. As part ofits contingency planning, GPU assessed the benefits of all existing projects and regulatory commitments in light of this announcement. Technical Specification 4.5.A.1 has been identified as a regulatory commitment whose risk benefit would not warrant the personnel radiation exposure and cost associated with its implementation, assuming the facility would operate a single cycle after the completion of the Type A test. A copy ofGPU Nuclear's risk assessment is prosided as Attachment No. 3.
1 9806100060 990528 PDR ADOCK 05000219:
P PDR '
rg
~
' be d V
j 6L40-98-20080 Page 2 1,
A final decision with respect to the plant's future has not yet been made. The subject TSCR requests that the requirement to perform the first Primary Containment Leakage Rate Testing Program Type A i
test be changed to 18R. The proposed change would provide GPU with the flexibility to ensure activities are conducted consistent with the future of the OCNGS.
l This license amendment application has undergone a safety review in accordance with Section 6.5 of the Oyster Creek Technical Specifications and has been evaluated under the criteria of 10 CFR 50.92.
(
If there are any questions or additional information is required, please contact Mr. Joseph D. Lachenmayer of l-my staffat 973-316-7971.
L Very truly yours, l
MichaelB. Roche Vice President and Director L
Oyster Creek
(.
l.
s Attachments cc:
Administrator, Region l' NRC Senior ResidentInspector NRC Project Manager L
i l
l-J
l GPU Nuclear,Inc.
(
U.S. Route M South i
NUCLEAR Post Office Box 388 Forksd River, NJ 08731-0388 Tel 609-971-4000 May 28, 1998 6L40-98-20080 i
l Mr. Kent Tosch, Director Bureau ofNuclear Engineering Department ofEnvironmental Protection CN 411 Trenton,NJ 08625
Dear Mr. Tosch:
Subject:
Oyster Creek Nuclear Generating Station Facility Operating License No. DPR-16 Technical Specification Change Request No. 254 Pursuant to 10 CFR 50.91(b)(1), please find enclosed a copy of the subject document which was filed with the United States Nuclear Regulatory Commission on May 28, 1998.
Very truly yours, Micine!B. Roche Vice President and Director q
Oyster Creek i
Attachment l
i l
i
l GPU Nuclear,Inc.
l
(
U.S. Route #9 South NUCLEAR Post Office Box 388 Forked River, NJ 087310388 Tel 609-971-4000 I
May 28, 1998 6L40-98-20080 The Honorable Louis A. Amato, Jr.
Mayor ofLacey Township 818 West Lacey Road l
Forked River, NJ 08731
Dear Mayor Amato:
Enclosed herewith is one copy of Technical Specification Change Request No. 254 for the Oyster Creek Nuclear Generating Station Operating License.
This document was filed with the United States Nuclear Regulatory Commission on May 28, 1998.
Very truly yours, f
0 Michael B. Roche Vice President and Director Oyster Creek Attachment l
t
United States ofAmerica Nuclear Regulatory Commission In the Matter of
)
)
Docket No. 50-219 GPU Nuclear, Inc.
)
Certificate of Senice This is to certify that a copy of Technical Specification Change Request No. 254 for Oyster Creek Nuclear Generating Station Operating License, filed with the U.S. Nuclear Regulatory Commission on May 28,1998 has this day ofMay 28,1998, been served on the Mayor of Lacey Township, Ocean County, New Jersey by deposit in the United States mail, addressed as follows:
The Honorable Louis A. Amato, Jr.
Mayor ofLacey Township 818 West Lacey Road Forked River, NJ 08731 By:
Michael B. Roche Vice President and Director Oyster Creek