t Be ver Valley Power Staten Shippingport. PA 15077@04 y
NWear Grnup 14W 643 6256 April 6, 1989 U.
S. Nuclear Regulatory Commission Attn:
Document Control Desk Washington, DC 20555
Reference:
Beaver Valley Power Station, Unit No. 2 Docket No. 50-412, License No. NPF-73 NRC Bulletin 88-02 l
Gentlemen:
By letter dated March 28,
- 1988, Duquesne Light Company (DLC) replied to NRC Bulletin 88-02 " Rapidly Propagating Fatigue Cracks in Steam Generator Tubes" and stated there was no evidence of denting at l
the upper support plate for Beaver Valley Unit 2 (BV-2).
The NRC reviewed our response and issued a safety evaluation by letter dated l
February 10, 1989 (TAC 67297)~.
Although not required by the Bulletin at this time, DLC has evaluated the susceptibility of the BV-2 steam generator tubes to rapidly propagating fatigue cracks assuming.that the tubes at the upper support plate are in a " dented" or " tube
' locked" condition.
Based on this evaluation, two (2) tubes (R11C4 and R9C33) in the BV-2 "C"
steam generator will be preventative 1.y plugged with leak limiting plugs during our current refuel _ag outage.
These actions would be required by Item C.2 of the Bulletin if denting is found in the future.
We are submitting this evaluation for NRC review and approval.
Enclosed are:
1.
Four (4) copies of WCAP-12141 entitled, " Beaver Valley Unit 2
Evaluation for Tube Vibration Induced Fatigue (Proprietary).
2.
Four (4) copies of WCAP-12142 entitled, Beaver Valley Unit 2 Evaluation for Tube Vibration Induced Fatigue (Non-Proprietary).
Also enclosed is a Westinghouse authorization letter, CAW-89-038, Proprietary Information Notice, and accompanying Affidavit.
8904120388 890406 PDR ADOCK 05000412 Q
iM q04 Ne 9?'
i iet QDAf
. Beaver Valley Power Station, Unit No. 2 Docket No. 50-412, License No. NPF-73 Page 2 l
As item 1
contains information proprietary to Westinghouse Electric Corporation, it is supported by an affidavit signed by Westinghouse, the owner of the information.
The affidavit sets forth the bases on which the information may be withheld from public disclosure by the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of Section 2.790 of the Commission's regulations.
l Accordingly, it is respectfully requested that the information which is proprietary-to Westinghouse be withheld from public disclosure in accordance with 10 CFR Section 2.790 of the Commission's regulations.
Correspondence with respect to the proprietary aspects of the Application for Withholding or the supporting Westinghouse Affidavit should reference CAW-89-038 and should be addressed to R.
A.
Wiesemann, Manager of Regulatory Legislative
- Affairs, Westinghouse Electric Corporation, P.
O.
Box 355, Pittsburgh, PA 15230-0355.
If there are any questions concerning this matter, please contact my office.
l Very truly yours, OC 3 aqs J. D.
Sieber Vice President Nuclear Group Enclosures cc: