Refers to 971217 Request for Relief from ASME BPV Code Re Visual Exam & Functional Testing of Snubbers.Forwards SE Authorizing Proposed Alternative Use of Current TS 3/4.7.8 Requirements for Snubber Visual Exam & Functional Testing
ML20248B031
Person / Time
Site: McGuire, Mcguire  
Issue date: 05/27/1998
From: Berkow H
NRC (Affiliation Not Assigned)
To: Barron H
DUKE POWER CO.
Shared Package
ML20248B037 List:
References
TAC-MA0623, TAC-MA0624, TAC-MA623, TAC-MA624, NUDOCS 9806010152
Download: ML20248B031 (3)


Text

c May 27, 1998 Mr. H. B. Barron Vice President, McGuire Site Duke Energy Corporation 12700 Hagers Ferry Road Huntersville, North Carolina 28078-8985

SUBJECT:

RELIEF REQUEST FOR SNUBBER VISUAL EXAMINATION AND FUNCTIONAL TESTING FOR MCGUIRE NUCLEAR STATION, UNITS 1 AND 2 (TAC NOS. MA0623 AND MA0624)

Dear Mr. Barron:

By letter dated December 17,1997, you requested relief from the requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code Section XI,1989 Edition, Article IWF-5000, Subsection IWF-5300, with regard to visual examination and functional testing of snubbers. Pursuant to the provisions of 10 CFR 50.55a(a)(3)(l), the staff authorizes the proposed altemative use of the current Technical Specification Section 3/4.7.8 requirements for snubber visual examination and functional testing, based on a finding that the proposed alternative provides an acceptable level of quality and safety.

The staff considers this matter resolved and is closing out TAC Nos. MA0623 and MA0624.

Sincerely, ORIGINAL SIGNED BY:

Herbert N. Berkow, Director Project Directorate 11-2 Division of Reactor Projects - l/II Office of Nuclear Reactor Regulation Docket Nos. 50-369 and 50-370

Enclosure:

As stated cc w/ encl: See next page Distribution:

HBerkow Alee LPlisco, Ril Docket File LBerry KManoly COgle, Ril i

PUBLIC FRinaldi GHill(4)

I j PD 11-2 Rdg.

TLH-3 (e-mail SE only)

ACRS JZwolinski OGC MTschiltz, EDO Oj yI To rec:ive a copy of this document, Indicate in the box:"C" = opy without attachment / enclosure "E" = Cop j - with tttachment/ enclosure "N" = No copy J g pd l

OFFICE PM:PDil-2 LA:PDil-2 l OGC,p4Vi D:PDS,7W l

NAME FRinaldi:enA-LBerry 93G#'

HBprkovV DATE f /V/98

/ /98 f //4/98 6 V)e/98

/ /98

/ /97 DOCUMENT NAME: G:\\MCGUIRE\\RRMA0623.WPD FFICIAL RECORD COPY NBC RE CENTER C#"

9806010152 980527 DR ADOCK 050 9

g :rgg

,o S

UNITED STATES l

j NUCLEAR RECULATORY COMMISSION

.o#g WASHINGTON, D.C. 20086-4001 May 27, 1998 Mr. H. B. Barron

)

Vice President, McGuire Site l

Duke Energy Corporation l

12700 Hagers Ferry Road l

Huntersville, North Carolina 28078-8985

)

SUBJECT:

RELIEF REQUEST FOR SNUBBER VISUAL EXAMINATION AND FUNCTIONAL TESTING FOR MCGUIRE NUCLEAR STATION, UNITS 1 AND 2

)

(TAC NOS. MA0623 AND MA0624)

{

Dear Mr. Barron:

By letter dated December 17,1997, you requested relief from the requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code Section XI,1989 Edition, Article IWF-5000, Subsection IWF-5300, with regard to visual examination and functional testing of snubbers. Pursuant to the provisions of 10 CFR 50.55a(a)(3)(i), the staff authorizes the proposed alternative use of the current Technical Specification Section 3/4.7.8 requirements for snubber visual examination and functional testing, based on a finding that the proposed alternative provides an acceptable level of quality and safety.

The staff considers this matter resolved and is closing out TAC Nos. MA0623 and MA0624.

Sincerely,

/

i erbert N. Berkow, Director Project Directorate ll-2 Division of Reactor Projects - 1/Il Office of Nuclear Reactor Regulation Docket Nos. 50-369 and 50-370

Enclosure:

As stated cc w/ encl: See next page l

l e

1 I

l I

McGuire Nuclear Station cc:

Mr. Paul R. Newton Ms. Karen E. Long Legal Department (PBO5E)

Assistant Attomey General Duke Energy Corporation North Carolina Department of 422 South Church Street Justice l

Charlotte, North Carolina 28242 P. O. Box 62g l

Raleigh, North Carolina 27602 County Manager of Mecklenburg County L. A. Keller 720 East Fourth Street Manager-Nuclear Regulatory Charlotte, North Carolina 28202 Licensing Duke Energy Corporation Michael T. Cash 526 South Church Street Regulatory Compliance Manager Charlotte, North Carolina 28242 Duke Energy Corporation McGuire Nuclear Site Regional Administrator, Region ll 12700 Hagers Ferry Road U.S. Nuclear Regulatory Commission Huntersville, North Carolina 28078 Atlanta Federal Center 61 Forsyth Street, S.W., Suite 23T85 J. Michael McGarry, lil, Esquire Atlanta, Georgia 30303 Winston and Strawn 1400 L Street, NW.

Elaine Wathen, Lead REP Planner Washington, DC 20005 Division of Emergency Management 116 West Jones Gtreet

' Senior Resident inspector Raleigh, North Carolina 27603-1335 c/o U.S. Nuclear Regulatory Commission Mr. Richard M. Fry, Director 12700 Hagers Ferry Road Division of Radiation Protection Huntersville, North Carolina 28078 North Carolina Department of Environment, Health and Natural Mr. Peter R. Harden, IV Resources Account Sales Manager 3825 Barrett Drive Westinghouse Electric Corporation Raleigh, North Carolina 27609-7721 Power Systems Field Sales P. O. Box 7288 Mr. T. Richard Puryear Charlotte, North Carolina 28241 Owners Group (NCEMC)

Duke Energy Corporation Dr. John M. Barry 4800 Concord Road Mecklenberg County York, South Carolina 29745 Department of Environmental Protection 700 N. Tryon Street Charlotte, North Carolina 28202

_ _ _ _ - - _ - _ _ _ _ _ _ - _ _ _ _ _ _ _