AUG - 4 1989 :
In Reply Refer To:
' Dockets: ' 50-445/89-51l
'
50-446/89-51
Mr. W.lL Cahill
Executive Vice President-
TU' Electric
400. North Olive Street, Lock Box 81
Dallas, Texas
75201
l
L
Dear Mr. Cahill:.
This refers to the inspection conducted by Mr.
C. Hale during the;
.
period. July 6 through August 1, 1989, of activities authorized by1
NRC Construction Permits CPPR-126 and CPPR-127 for the Comanche-
Peak Steam Electric' Station, Units'1 and 2, and to the discussion-
of our findings with H. D.Bruner and other members of your staff-
~
at.the conclusion of.the inspection..
The enclosed copy of our inspection report identifies areas
examined during the inspection.
Within these areas, the inspection.
consisted of aelective examination of procedures and-representative
records, interviews'with personnel, and observations by,the
inspectors.
Within the scope of the inspection, no violations or deviations
were identified.
In accordance with 10 CFR 2.790 of'the Commission's regulations, a'
copy of this letter'and the enclosed inspection report will be
placed in the NRC Public Document Room.
'
Should you have any questions concerning this inspection,-we will-
be pleased to discuss them with you'.
L
Sincerely,
- ORIGINAL SIGNED BY R. F. WARNICT
R. F. Warnick, Assistant Director
for Inspection Programs
Comanche. Peak Project Division
. Office of Nuclear Reactor Regulation
Enclosure:
.
.
Inspection Report 50-445/89-51; 50-446/89-51
cc w/ enclosure:
See next page
R fu) &
R R O h r*
'
IP:CPPD:NRR-
IP:CPPD:NRR-
AD:IP:CPPD:NRR
/
h
,
CHale
HLivermore
RWarnick RFA/
1
8/F /89
.
8/V /89
8/.f/89
-
.,
g
~
89080S0194 890804
ADOCK 05000445
"
,
O
'
-_ . _ _ _ _ _ _ _ _ _ _ .
.
jef *"% -
< ,
.
M
UNITED STATES
y
%-
NUCLEAR REGULATORY COMMISSION
j
i ,g -
WASHINGTON, D. C. 20555
.
,w,
O ~b S
In Reply Refer To:
Dockets:
50-445/89-51
50-446/89-51
Mr. W.
J.
Cahill, Jr.
,
Executive Vice President
i
TU Electric
400 North Olive Street, Lock Box 81
,
Dallas, Texas
75201
'
Dear Mr. Cahill:
This refers to the inspection conducted by Mr. C. Hale during the
period July 6 through August 1, 1989, of activities authorized by
NRC Construction Permits CPPR-126 and CPPR-127 for the Comanche
,
Peak Steam Electric Station, Units 1 and.2, and to the discussion
of our findings with H. D. Bruner and other members of your staff
at the conclusion of the inspection.
The enclosed copy of our inspection report identifies' areas
I
examined during the inspection.
Within these areas, the inspection
consisted of selective examination of procedures and representative
records, interviews with personnel, and observations int the
-
inspectors.
l
Within the scope of the inspection, no violations or deviations
f
l
were identified.
3
In accordance with 10 CFR 2.790 of the Commission's regulations, a
copy of this letter and the enclosed inspection' report will be
placed in the NRC Public Document Room,
l
should you have any questions concerning this inspection, we will
be pleased to discuss them with you.
Sincerely,
RFWA
i
R. F. Warnick, Assistant. Director
'
for Inspection Programs
comanche Peak Project Division
Office of Nuclear Reactor Regulation'
)
Enclosure:
i
Inspection Report 50-445/89-51; 50-446/89-51
cc w/ enclosure:
See next page
.
_ . _ _ _ _ _ _ _ _ _ _ _ _ _ . .
..
?4
i-
.
.-
.
p.
.
.
.
50-445/99-St ; 50-446/89-Si
.
DISTRIBUTION:
DN
NRC PDR' $ NEE NS1$$5M kO M
-
LPDR
CPPD-LA
CPPD Reading (HQ)
ADSP Reading
Site Reading. File
- R. Warnick
- J. Wiebe
- H.
Livermore
- MIS System, RIV
- RSTS Operator, RIV
RPB, RIV
RIV Docket File
'
- L.
Shea, ARM /LFMB
J. Taylor
C. Grimes
P. McKee
J. Lyons
J. H. Wilson
l
M. Malloy
J. Moore, OGC-WF
M. Fields
J. Gilliland, RIV
D. Crutchfield
E. Jordan
l
B. Grimes
B. Hayes
j
1
- w/766
)
i
l
4
l
I
l
l
i
_ _ - _ _ _ - _ - - - _ - _ _ _ _ - -. _ _ _ _ - - - - _ _ - - - - _ _ _ _ _ _ _ _ _ _ _ _ - -
- _____--- -._- __ _--_--_ --___----__-_ -_- __ - ----_.--___- _..-_
_ - _ . ,
~
]
I
-
-
.
-
.
,
'
. J. Cahill, Jr.
l
1
cc w/ enclosure:
l
Roger D. Walker
TU Electric
Manager, Nuclear Licensing
c/o Bethesda Licensing
TU Electric
3 Metro Center, Suite 610
Skyway Tower
Bethesda, Maryland
20814
-
400 North Olive Street, L.B. 81
j
Dallas, TX
75201
E. F. Ottney
P. O.. Box 1777
Juanita Ellis
Glen Rose,' Texas
76043
l
President - CASE
i
1426 South Polk Street
Jack R. Newman
Dallas, TX
75224
.Newman & Holtzinger
1615 L Street,.NW.
!
Chief, Texas Bureau of
Suite-1000
Radiation Control
-Washington, DO
20036
i
Texas Department of Health
1100 West 49th Street
,
GDS Associates, Inc.
1850 Parkway Place, Suite 720
Marietta, GA
30067-8237
Honorable George Crump
County Judge
Glen Rose, Texas
76043
(
Ms. Billie Pirner Garde, Esq.
Garde Law Office
104 Eust Wisconsin Avenue
)
Appleton, WI
54911
Regional Administrator, Region IV
U.S. Nuclear Regulatory Commission
611 Ryan Plaza Drive, Suite 1000-
'
Arlington, Texas
76011
William A. Burchette, Esq.
Counsel for Tex-La Electric
' Cooperative of Texas
Heron, Burchette, Ruckert & Rothwell
i
L
1025 Thomas Jefferson St.,
NW
'
20007'
,
)
i
i
.
_--_-------,-,--------------_---__---------x--_
- - - - _ - - - - _ _ _ - - - - - - - . - _ _ - . _ - - -
- . - _ _ -
--
- - - - - - - - - - - -
-
- _ _
-- - - . - - - . _ - - .
-
-)
-