ML20247R097
| ML20247R097 | |
| Person / Time | |
|---|---|
| Site: | Big Rock Point File:Consumers Energy icon.png |
| Issue date: | 07/31/1989 |
| From: | Wright G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Hoffman D CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
| References | |
| NUDOCS 8908070344 | |
| Download: ML20247R097 (12) | |
Text
mm.,
M*O..
?
"M I
,.m o.:
- y i } q.t '
g
.,y:
.JUL 31 1389 Docket _No.150-155
. Consumers Power Company p
ATTN: ' David P. Hoffman
-l
,Vice President i
Nuclear Operations 1
~1945 West Parnall Road-l Jackson, MI 49201 1
i
Dear Mr. Hoffman:
)
1
SUBJECT:
OPERATOR AND SENIOR OPERATOR LICENSING EXAMINATIONS LIn a telephone ~ conversation on July 24, 1989, between Mr. Dennis'G. La Croix, Nuclear Traning Administrator, and Mr. Gregory M.-Nejfelt, Chief Examiner,
)
arrangements were made for,the administration of examinations at the Big Rock point.
j The written and oral examinations are scheduled for the week of November 13, i
1$89.
i In' order for us to meet this schedule, it will be necessary for the facility.
i to furnish the approved reference material listed in Enclosure'1, " Reference
' Material Requirements.for Reactor / Senior Reactor Operator Licensing.
Examinations" at least 60 days prior to the examination date. Any delay in receiving approved properly bound and indexed reference material will result in a delay' in. administering the examinations.
Mr. La Croix has been advised 1
-of our reference material requirements, the number of reference material sets j
that'are required, and the examiners names and addresses where each set is to be mailed.
i The facility ~ management is responsible for providing adequate space and i
accommodations in order to properly conduct the written examinations.
~ Enclosure 2, " Requirements.for Administration of Written Examinations,"
l describes our requirements for conducting these examinations.
j Mr..La'Croix has also been informed of these requirements.
{ contains the Rules and Guidelines that will be in effect during the administration of the written examination.
The frcility management is responsible' for ensuring that all applicants are aware of these Rules.
]
1
-The. facility staff' review of the written examination will be conducted in
)
accordance with requirements specified in Enclosure 4, " Requirements for Facility Review of Written Examinations." Mr. La Croix has been informed
)
of these requirements.
j l
f, it
/Ekg
Consumers Power Company 2
JUL 31 m All reactor operator and senior reactor operator license applications should be submitted at least 60 days prior to the first examination dates so that we will be able to review the training and experience of the. applicants, process the medical certifications, and prepare final examiner assignments after applicent eligibility has been determined.
If the applications are not received at least 30 days prior to the examination dates, it is likely that a postponement will be necessary.
This request is covered by Offica of Management and Budget Clearance Number 3150-0101 which expires May 31, 1992. The estimated average burden is 7.7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> per response, including gathering, xeroxing and mailing the required material. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to the Records and Reports Management Branch, Division of Informatiori Support Services, Office of Information Resources Management, U.S. Nuclear Regulatory Comrtission, Washington, D.C.
20555; and to the Paperwork Reduction Project (3150-0101), Office of Management and Budget, Washington,.D.C. 20503.
Thank you for your consideration in this matter.
If you have any l
questions regarding the examinatico procedures and requirements, please contact G. M. Nejfelt at (312) 790-5528.
Sincerely, C 2' l li ;D BY GE0ffREY C. WU mii l
Geoffrey C. Wright, Chief Operations Branch
Enclosures:
1.
Reference Material Requirements for Reactor /Sanior Reactor Operator Licensing Examinations 2.
Requirements for Administration of Written Examinations 3.
NRC Rules and Guidelines For Written Examinations 4.
Requirements for Facility Review of Written Examinations See Attached Distribution l
RIII RUJ FJII 7el J
'/
, 97 J
f r.;
~
Consumers Power Company 3
dCl 3 l' ?^'n ec w/ enclosures:
Mr. Kenneth W. Berry, Director
- Nuclear Licensing
. Thomas W. Elward, Plant Manager-DCD/DCB (RIDS)
Licensing Fee Management Branch Resident Inspector, RIII Ronald Callen, Michigan Public Service Commission Michigan Department of Public Health D.' G.'La Croix, Plant Training Manager cc w/o enclosures:
L. Kelly, Project Manager, NRR K. E. Perkins, Branch Chief, OLB I.. N. Jackiw, Section Chief, DRP 1
l l
REFERENCE MATERIAL REQUIREMENTS FOR REACTOR / SENIOR REACTOR OPERATOR LICENSING EXAMINATIONS 1.
Existing learning ob,iectives, Job Performance Measures and lesson plans (including training manuals, plant orientation manual, system descriptions, reactor theory, thermodynamics, etc.)
A copy of the facility Job and Task Analysis (JTA), specifying the knowledges and abilities required of an operator at the facility.
Each particular knowledge and/or ability will include an importance rating correlating it to ensuring the health and the safety of the public.
If a JTA is not furnished, the Knowledges and Abilities Catalog for Nuclear Power Plant Operators, NUREG-1122 (1123) will be used to establish content validity for the examination.
All Job Performance Measures (JPMs) used to ascertain the competence of the operators in performing tasks within the control room complex and, as identified in the facility JTAs, outside of the control room, i.e., local operations.
Training materials should include all substantive written material used for preparing applicants for initial R0 and SR0 licensing.
The written material should include learning objectives and the details presented during lectures, rather than outlines.
Training materials should be identified by plant and unit, bound, and indexed.
FAILURE TO PROVIDE COMPLETE, Pa~?ERLY B0UND AND INDEXED PLANT REFERENCE MATERIAL MAY RESULT IN THE RETURN OF THE MATERIAL TO THE PERSON WHO IS THE HIGHEST LEVEL OF CORPORATE MANAGEMENT WHO IS RESPONSIBLE FOR PLANT OPERATIONS (E.G., VICE PRESIDENT OF NUCLEAR OPERATIONS).
ACCOMPANYING THE MATERIAL WILL BE A COVER LETTER EXPLAINING THE DEFICIENCIES IN THE REFERENCE MATERIAL AND THE FACT THAT THIS WAS THE REASON THE EXAMINATIONS WERE CANCELLED OR POSTPONED.
Training materials which include the following should be provided:
System descriptions including descriptions cf all operationally relevant flow paths, components, controls and instrumentation.
System training material should draw parallels !o the actual procedures used for operating the applicable systea Complete and operationally useful descriptions of all safety-system interactions and, whcre available, B0P system interactions uMer emergency and abnormal conditions, including consequences of anticipated operator error, maintenance error, and equipment failure.
Training material used to clarify and strengthen understanding of emergency operating procedures.
J l
i
_-----_-J
G l
1 Comprehensive theory material that includes fundamentals in the area of theory of reactor operation, thermodynamics, heat transfer and fluid f1w. as well as specific application to actual in plant components.
For example, mechanical theory material. on pumps should include pump theory as well as descriptions of how these principles actually apply to major plant pumps and the systems in which they are installed (i.e., Reactor Coolant Pumps, all ECCS pumps, Recirculation pumps, Feedwater pumps and Emergency Feedwater pumps).
Reactor Theory material should include descriptions that draw explicit ties between the fundamentals and the actual operating limits followed in the plant (i.e., reactor theory material should contain explanations how principles relate to the actual curves used by operators to verify shutdown margin or calculate an ECP).
2.
Complete Procedure Index (including surveillance procedures, etc.)
3.
All administrative procedures (as applicable to reactor operation or safety) 4.
All integrated plant procedures (normal or general operating procedures) 5.
Emergency procedures (emergency instructions, abnormal or special procedures) 6.
Standing orders (important orders that are safety related and may supersede the regular procedures) 7.
Surveillance procedures (procedures that are run frequently, i.e., weekly or that can be run on the simulator) 8.
Fuel-handling and core-loading procedures, (initial core-loading procedure, when appropriate) 9.
Annunciator / alarm procedures 10.
Radiation protection manual (radiation control manual or procedures) 11.
Emergency plan implementing procedures 12.
Technical Specifications (and interpretations, if available) for all units for which licenses are sought.
13.
System operating procedures 14.
Piping and instrumentation diagrams, e betrical single-line diagrams, or flow diagrams 2
0 15.
Technical Data Book, and/or plant curve information as used by operators and' facility precautions, limitations, and set points (PLS) for.the facility.
16.
Questions and answers specific to the facility training program which may be used.in the written or operating examinations (voluntary by facility licensee) 17.
The following on the plant reference simulation facility a.
List of all praprogramed initial conditions b.
List of all preset malfunctions with a clear identification number.
The list should include cause and effect information.
Specifically, for each malfunction a co vise description of the expected result, or range of results, that 'ill occur upon implementation should be provided. Additionally, an indication of which annunciators are to be initially expected should be given.
c.
A description of simulator failure capabilities for valves, breakers, indicators and alarms d.
Where the capability exists, an explanation of the ability to vary the severity of a particular malfunction should be provided, i.e.,
ability to vary the size of a given LOCA or steam leak, or the -
ability to cause a slow failure of a component such as a feed pump, turbine generator or major valve (e.g., drifting shut of a main feedwater control valve) e.
An identification of modeling conditions / problems that may impact the examination f.
Identification of any known performance test discrepancies not yet corrected g.
Identification of differences between the simulator and the reference plant's control room h.
Copies of facility generated scenarios that expose the applicants to situations of degraded pressure control (PWR), degraded heat removal capability (PWR and BWR) and containment challenges (PWR and BWR) may be provided (voluntary by licensee) i.
Simulator instructors manual (voluntary by licensee) j.
Description of the scenarios used for the training class (voluntary by licensee) t 3
hi 18.
Additional material required by the examiners to develop examinations that meet the requirements of these Standards and the regulations.
The above reference material should be approved, final issues and should be so marked. _If a plant has not finalized some of the material, the Chief Examiner shall verify with the facility that the most complete, up-to-date material is available and that' agreement has been reached with the licensee for limiting changes befo.e the administration of the examination.
All procedures and reference material should be bound with appropriate indices or tables of contents so that they can be used efficiently.
Failure to provide complete, properly bound and indexed plant reference material could result in cancellation or rescheduling of the examinations.
4 l
REQUIREMENTS FOR ADMINISTRATION OF WRITTEN EXAMINATIONS L
1.
A single room shall be pre ided for administration of the written examina-tion.
The-location of this room and supporting restroom facilities shall be such as to prevent contact with all other facility and/or contractor personnel during the written examination.
If necessary, the facility should make arrangement for the use of a suitable room at a local school, mote, or other building.
Obtaining this room is the responsibility of the licensee.
2.
Minimum spacing is required to ensure examination integrity as determined by the Chief Examiner. Minimum spacing should be one applicant per table, with a three foot space between tables.
3.
Suitable arrangements shall be made by the facility if the applicants are to have lunch, coffee or other refreshments.
These arrangements shall comply with Item 1 above and shall be reviewed by the examiner and/or.
proctor.
4.
The facility licensee shall provide pads of 8-1/2 by 11 inch lined paper in unopened packages for each applicant's use in completing the examination.
The examiner shall distribute these pads to the applicants.
5.
Applicants may bring pens, pencils, calculators or slide rules into the examination room.
Only black ink or dark pencils should be used for writing answers to questions.
6.
The licensee shall provide one set of steam tables for each applicant.
The examiner shall distribute the steam tables to the applicants.
No wall charts, models, and/or other training materials shall be present in the examination room.
No other equipment or reference material shall be allowed unless provided by the examiner.
PROCEDURES FOR THE ADMINISTRATION OF WRITTEN EXAMINATIONS 1.
Check identification badges.
2.
Pass out examinations and all handouts.
Remind applicants not to review examination until instructed to do so.
READ THE FOLLOWING INSTRUCTIONS VERBATIM:
During the administration of this examination the following rules apply:
1.
Cheating on the examination means an automatic denial of your application and could result in more severe penalties.
2.
After the examination has been completed, you must sign the statement on the cover sheet indicating that the work is your own and you have not received or given assistance in completing the examination.
This must be done after you complete the examination.
READ THE FOLLOWING INSTRUCTIONS:
1.
Restroom trips are to be limited and only one applicant at a tira may leave.
You must avoid all contacts with anyone outside the examination room to avoid even the appearance or possibility of cheating.
2.
Use black ink or dark pencil on'.i to facilitate legible reproductions.
3.
Print your name in the blank provided in the upper right-hand corner of the examination cover sheet.
4.
Fill in the date on the cover sheet of the examination (if necessary).
5.
You may write your answers on the examination question page or on a separate sheet of paper.
USE ONLY THE PAPER PROVIDED AND DO NOT WRITE ON THE BACK SIDE OF THE PAGE.
6.
If you write your answers on the examination question page and you need more space to answer a specific question, use a separate sheet of the paper provided and insert it directly after the specific question.
00 NOT WRITE ON THE BACK SIDE OF THE EXAMINATION QUESTION PAGE.
7.
Print your 11ame in the upper right hand corner of the first page of each section of your answer sheets whether you use the examination question pages or separate sheets of paper.
Initial each page.
8.
Before you turn in your examination, consecutively number each answer sheet, including any additional pages inserted when writing your answers on the examination questinn page.
l s.
9.
If you are using separate sheets, number each answer as to category and number (i.e., 1.04,6.10) and skip at least 3 lines between answers to allow space for grading.
- 10. Write "End of Category
" at the end of your answers to a category.
11.
Start each category on a new page.
- 12. Write "Last Page" on the last answer sheet.
13.
Use abbreviations only if they are commonly used in facility literature.
Avoid using symbols such as < or > signs to avoid a simple transposition error resulting in an incorrect answer.
Write it out.
14.
The point value for each question is indicated in parentheses after the question.
The amount of blank space on an examination question page is NOT an indication of the depth of answer required.
15.
Show all cal.;ulations, methods, or assumptions used to obtain an answer.
16.
Partial credit may be given.
Therefore, ANSWER ALL PARTS OF THE QUESTION AND DO NOT LEAVE ANY ANSWER BLANK.
17.
Proportional grading will be applied.
Any additional wrong information that is provided may count against you.
For example, if a question is worth one point and asks for four responses, each of which is worth 0.25 points, and you give five responses, each of your responses will be worth 0.20 points.
If one of your five responses is incorrect, 0.20 will be deducted ar.d your total credit for that question will be 0.80 instead of 1.00 even though you got the four correct answers.
18.
If the intent of a question is unclear, ask questions of the examiner only.
- 19. When turning in your examination, assemble the completed examination with examination questions, examination aids and answer sheets.
In addition, turn in all scrap paper.
20.
To pass the examination, you must achieve an overall grade of 80% or greater and at lease 70% in each category.
21.
There is a time limit of (6) hours for completion of the examination.
(Or some other time if less than the full examination is taken).
PARAGRAPH 7:
LICENSE EXAMINATIONS ENCLOSURE 3 (Cont'd)
- 22. When you are done and have turned in your examination, leave the examination area (DEFINE THE AREA).
If you are found in this area while the examination is still in progress, your license may be denied or revoked.
2
i REQUIREMENTS FOR FACILITY REVIEW 0F WRITTEN EXAMINATIONS 1.
At the option of the Section Chief, the facility may review the written examination up to two weeks prior to its administration.
This review may take place at the facility or in the Regional office.
The Chief Examiner will coordinate the details of the review with the facility.
An NRC examiner will always be present during the review.
Whenever this option of examination review is utilized, the facility reviewers will sign the following statement prior to being allowed access to the examination.
The examination or written notes will NOT be retained by the facility.
a.
Pre-Examination Security Agreement I
agree that I will not knowingly divulge any information concerning the replacement (or initial) examination scheduled for to any unauthorized persons.
I understand that I am not to participate in any instruction involving those reactor operator or senior reactor operator applicants scheduled to b administered the above replacement (or initial) examination from now until after the examination has been administered.
I understand that violation of this security agreement could result in the examination being voided.
Signature /Date In addition, the facility staff reviewers will sign the following statement after the written examination has been administered.
b.
Post-F.xamination Security Agreement I
did not, to the best of knowledge, divulge any information concerning the written examination administered on to any unauthorized persons.
I did not participate in providing any instruction to l
those reactor operator and senior reactor operator applicants who were administered the examination from the time that I was allowed access to the examination.
l-Signature /Date 2.
Regardless of whether the above examination review option is exercised, immediately following the administration of the written examination, the facility staff shall be provided a marked-up copy of the examination and the answer key.
The copy of the written examination shall include pen and ink changes made to questions during the examination administration.
%,v l 4
.>O,'
- If2the facility did not review the examination prior to its administration, they will have five (5) working days from the day of the written examination to submit formal comments.
If the facility reviewed the
. examination prior to its administration, 'any additional comments must be given to an examiner prior to his/her leaving the site at the 'end of the week of the written examination administration.
In either case, the comments will be addressed to the responsible Regional Office byLthe' highest onsite level of corporate management for plant operations, e.g.,
-Vice President for Nuclear Operations.
A copy of the submittal will be forwarded to the Chief Examiner, as appropriate.
Comments not submitted within the required time frame will be considered for inclusion in the grading process on a case-by-case basis by the Regional Office Section Chief.
Should the comment submittal deadline not.be met, a long delay in. grading the examinations may occur.
L-3.
The following format should be adhered to for submittal of specific comments:
- a.
Listing'of NRC Question, answer and reference b.
Facility comment / recommendation c.
Reference (to support facility comment)
NOTES:
1.
-No change to the examination will be.made without submittal of a reference to support the facility comment.
Any supporting documentation that was not previously supplied, should be l-provided.
2.
Comments made without a concise facility recommendation will not be addressed.
l l
l sv
- - - - - - - _