A; September 18, 1989 Docket No. 50 395 Mr. O. S. Bradham Vice President, Nuclear Operations i
South Carolina Electric & Gas Company i
Virgil C. Summer Nuclear Station P.O.' Box 88 Jenkinsville, South Carolina 29065
Dear Mr. Bradham:
SUBJECT:
CLOSE0VT OF BULLETIN 89-01, FAILURE OF WESTINGHOUSE STEAM GENERATOR TUBE MECHANICAL PLUGS, FOR THE V. C. SUMMER NUCLEAR STATION UNITSNO.1(TACNO.73209)
The NRC staff has reviewed the information contained in your letter dated June 12,-1989 which was submitted in response to Bulletin 89 01, " Failure of Westinghouse Steam Generator Tube Mechanical Plugs". As a result of this review, the staff has concluded that your response conforms with the Bulletin and that no additional information is required at this time.
Implicit with your response is the commitment that you do not intend to install plugs with the thermally treated Inconel 600 heats identified in the Bulletin.
The information which was utilized in tne formation of your response shocid be l
maintained for inspection.
1 Sincerely, j
Original signed by i
John J. Hayes, Jr., Project Manager Project Directorate 11-1 Division of Reactor Projects - I/II n
,,.,g g Office of Nuclear Reactor Regulation
- o a.
$8 cc: See next page DISTF.IBUTION
[fd SDocket Eile:
PAnderson DFN 90 NRC & Local PDR!s JHayes MS PDII-1 R/F OGC (info. only)
I i R
SVarga EJordan oz Glainas BGrimes
$$c EAdensam ACRS(10)
EMurphy SUMMER FILE g
- . 3.j.0lI-1 P
- D:PDll-1 OFC :LA:PD
.... :...g
.___ r NAME: pan (
- J ayes: bid :EAdensa DATE:09//$/89
- 09///89
- 09/(I/89 OFHCIAL RECORD COPY Document Name:
SUMMER BULLETIN LTR i
- iQ l
[
s.-
g4 -
Mr. O. S. Bradham -
~ South Carolina Electric & Gas Company Virgil C. Sumer Nuclear Station cc:-
'Mr. Silliam A. Williams, Jr.
Technical Assistant - Nuclear Operations Santee Cooper.
'P. 0.~ Box 764'(Mail Code 153)
Columbia,, South Carolina.29218 J. B.: Knotts, Jr., Esq..
Bishop, Cook, Purcell and Reynolds 2400.L Street, N.W.
LWashington, D. C.
20005-3502 Resident Inspector / Summer NPS c/o U.S. Nuclear Regulatory Commission Route 1, Box.64 Jenkinsville, South Carolina 29065' Regional Administrator, Region II U S. Nuclear Regulatory Commission, 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323 Chairman, Fairfield_ County Council P.'O. Box 293 Winnsboro, South Carolina 29180 Mr. Heyward G. Shealy, Chief
' Bureau of Radiological Health SouthLCarolinaDepartmentofHealth and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 South Carolina Electric.& Gas Company Mr. A. R. Koon, Jr., Manager Nuclear' Licensing Virgil C. Summer Nuclear Station P. O. Box 88 Jenkinsv111e, South Carolina 29065
-