._
[
l
-==
===' 7 Log '# TXX-89173-
=
Fi1e # 10110 r
=
903.9 7UELECTRIC.
Ref. # 10CFR50.55(e)
March 29, 1989 W.J.Cahm Executive Vke President U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C.
20555
SUBJECT:
' COMANCHE' PEAK STEAM ELECTRIC STATION (CPSES)
' DOCKET NOS. 50-445 AND 50-446 CONDUIT UNIONS SDAR:
CP-87-23 (SUPPLEMENTAL REPORT)
Gentlemen:
On July 27, 1987, TU Electric letter logged TXX-6565 'provided notification that the deficiency involving conduit unions was reportable under the provisions of 10CFR50.55(e). The last report on this issue, logged TXX-88860, was submitted December 15, 1988.
This supplemental report is being submitted to update the corrective action completion schedule.
Unit 1 corrective actions for this issue have been rescheduled-for completion by June 2, 1989.
The Unit 2 corrective action completion schedule remains unchanged.
Sincerely, William J. Cahill, Jr.
By:
D. R. Woodlan i
Docket Licensing Manger DAR/vid c - Mr. R. D. Martin, Region IV Resident Inspectors, CPSES (3) 8904060476 890329 PDR ADOCK 0500 5