This refers to the special onsite review conducted by the NRC Augmented
Inspection Team (AIT) composed of E. McKenna, G. VanSickle and M. Kunowski
of this office, S. Sands of the Office of Nuclear Reactor Regulation and an
NRC Consultant, S. Nealey, on April 25-28, 1989, of activities associated
with events at Braidwood Station Units 1 and 2, authorized by Operating
License Nos. NPF-72 and NPF-77 and to the discussion of our findings with
Mr. D. O'Brien at the conclusion of the inspection.
The enclosed copy of the AIT report identifies areas examined during the
inspection. kithin these areas, the inspection consisted of a selective
examination of procedures and records, observations, and interviews with
personnel.
No violations or deviations were identified. Reconunendations developed by
the team as a result of this inspection are included in the enclosure for
your consideration. A letter documenting your actions in response to the
inattentiveness incidents is requested within 60 days of receipt of this
letter.
In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of
this letter and the enclosure will be placed in the NRC's Public Document
Room.
We will gladly discuss any questions you have concerning this inspection.
Sincerely,
Original signed by E. G. Greenman
g 60g g y[gy@g56
Edward G. Greenman, Director
Division of Reactor Projects
{gg
g
Enclosure: Augmented Inspection
Team Report No. 50-456/89014(DRP);
k
No. 50-457/89014(DRP)
\\
f
See Attached Distribution
a
'
RIII
RIII
RIII
RIII
R
-(
q
(%
_%
grn
jp
Sand
Hinds
Greger
McKenna
Gre ni n
_-_
,:-
,.
,,.v'
.
MAY 2 61999
Docket No. 50-456
Docket No. 50-457
Commonwealth Edison Company
ATTN: Mr. Cordell Reed
Senior Vice President
Post Office Box 767
Chicago, IL 60690
Gentlemen:
This refers to the special onsite review conducted by the NRC Augmented
Inspection Team (AIT) composed of E. McKenna, G. VanSickle and M. Kunowski
of this office, S. Sands of the Office of Nuclear Reactor Regulation and an
NRC Consultant, S. Nealey, on April 25-28, 1989, of activities associated
with events at Braidwood Station Units 1 and 2, authorized by Operating
License Nos. NPF-72 and NPF-77 and to the discussion of our findings with
Mr. D. O'Brien at the conclusion of the inspection.
The enclosed copy of the AIT report identifies areas examined during the
inspection. Within these areas, the inspection consisted of a selective
examination of procedures and records, observations, and interviews with
personnel.
No violations or deviations were identified.
Recommendations resulting
from this inspecticn are included in the enclosure for your consideration.
A written response documenting your proposed actions from these events is
requested within 60 days of receipt of this letter.
In accordaace with 10 CFR 2.790 of the Commission's regulations, a copy of
this let'er and the enclosure will be placed in the NRC's Public Document
Room.
We will gladly discuss any questions you have concerning this inspection.
Sincerely.
Original signed by E. G. Greenaan
Edward G. Greenman, Director
Division of Reactor Projects
Enclosure: Augmented Inspection
Team Report No. 50-456/89014(DRP);
No. 50-457/89014(DRP)
S e Attached Distribution
3
t A9
RIII
NNy
QJ,
R
III
RIII
.
5
Fornev/jp
a ds
Hi
s
Gr er
McKen
Greenman
Nll ' '
5ff
b/l? 9
- - _ - _ -
..:-
..
'*
,.
- ,; . *
Commonwealth Edison Company
2
W26g
Distribution
cc w/ enclosure:
T.'J. Maiman, Vice President,
PWR Operations
T. Kovach, Nuclear
!
Licensing Manager
S. Hunsader, Nuclear
i
'
p
Licensing Administrator
R. E. Querio Station Manager
D. E. Cooper, Regulatory
DCD/DCB (RIDS)pervisor
Assurance Su
Licensing Fee Management Branch
Resident Inspector, RIII
Braidwood
Resident Inspector, RIII Byron
. D. W. Cassel , Jr. , Esq.
.
Richard Hubbard
J. W. McCaffrey, Chief, Public
Utilities Division
H. S. Taylor, Quality Assurance
Division
E. Chan, 0GC-
G. Berry, 0GC
1
S. P. Sands, NRR
F. Miraglia, NRR
l
G. Holahan, NRR
M. Virgilio, NRR
D. Muller, NRR
.
'
J. Roe, NRR
C. E. Rossi, NRR
W.-Lanning, NRR
1
E. Jordan, AE0D
W. Kane, RI
L. Reyes, RII
J. Callan, RIV
,
l
R. Zimmerman, RV
-
i
l
1
l
l
_
- - - - -
- - - _
- _ - - - - - _ _ -
_---_-_ _A