ML20247N233

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-352/89-17 & 50-353/89-25 on 890724-27.No Violations Noted.Corrective Actions Re Failure of Operators to Properly Classify Events Effective
ML20247N233
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 09/08/1989
From: Bellamy R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Corbin McNeil
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
Shared Package
ML20247N240 List:
References
NUDOCS 8909260177
Download: ML20247N233 (2)


See also: IR 05000352/1989017

Text

_ - - _

,

.. ..

i d

,

> *

.,

l

,

1:

1

SEP.O B M89

Docket Nos. 50-352 License Nos. NPF-27

50-353 CPPR-107

l

Philadelphia Electric Company

ATTN: Mr. C.'A. McNeill

Executive Vice President - Nuclear

Correspondence Control Desk -

P. O. Box 7520

l

Philadelphia, Pennsylvania 19101-

Gentlemen:

Subject: Combined Inspection Report Nos. 50 352/89-17 and 50-353/89-25

l

A special safety inspection of your emergency preparedness program was

conducted by C. Conklin, and other members of this office, on July 24-27, 1989

at your Limerick Generating Station, Limerick, Pennsylvania. Discussions of

our findings were presented by Mr. Conklin to Mr. Graham Leitch and other

members of your staff at the conclusion of the inspection.

l The area examined during .this inspection was limited to follow-up of the

events associated with the failure of your operators to properly classify

certain events during walk-through examinations. These concerns were

described in NRC Region I Combined Inspection Report 50-352/89-11 and 50-

i 353/B9-17. As described in the enclosed Inspection Report, this inspection

'

consisted of selective examination of procedures and representative records,

i

interviews with personnel, and observations by the inspector.

Within the scope of this inspection, no violations were identified. It was

determined that your corrective actions taken in response to the failure of

the operators to properly classify events were effective. No reply to this

letter is required. Your cooperation with us in this matter is appreciated.

i

Sincerely,

Original Sifned Dt'

Ro tald R. Ed */

Ronald R. Bellamy, Chief

Facilities Radiation Safety and

Safeguards Branch

Division of Radiation Safety

and Safeguards

i

'

\f

Enclosures:

l. NRC Region I Combined Inspection Report Nos. 50-352/89-17 and ig

50-353/89-25. .

^

8909260177 890908

PDR ADOCK 05000352 i;

'

G PNU

, _ _ _ - _ _ _ _ _ - _ _ _ _

'

'

-

..~

. ..

I

Philadelphia Elcaric. Company 2

cc w/ encl:

John S. Kemper, Sr., Senior Vice President - Nuclear

E. C. Kistner, Chairman, Nuclear Review Board

J. W. Gallagher, Vice President - Nuclear

Graham M. Leitch, Vice President, Limerick Genersting Station

Troy B.1 Conner, Jr., Esquire

. Eugene J. Bradley, Esquire, Assistant General Counsel

- W. M. Alden, Director, Licensing Section

Public Document Room (PDR) .

Local Public Document Room (LPDR)

Nuclear Safety.Information Center (NSIC)

NRC-Resident-Inspector

Commonwealth of Pennsylvania

bcc w/ encl:

Region I Docket Room (with concurrences)

Management-Assistant, DRMA (w/o enc 1)

J.-Linville, DRP

L. -Doerflein, DRP

T. Kenny, SRI

- Conklin Lazarus Be my

8/(k/89 /89 y/g/89

0FFICIAL RECORD COPY

i

l

i