ML20247M658

From kanterella
Jump to navigation Jump to search
Informs That NRC Will Conduct Exam Writing Workshop in Arlington,Tx on 980722-24.Workshop Designed to Follow Up on May 1997 Workshop & to Convey Exam Test Item Review Techniques for Operator Licensing Exam.Background Info Encl
ML20247M658
Person / Time
Site: Cooper 
Issue date: 05/15/1998
From: Pellet J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Horn G
NEBRASKA PUBLIC POWER DISTRICT
References
NUDOCS 9805260327
Download: ML20247M658 (15)


Text

!

l pa a%

UNITED STAT ES

}

NUCLEAR REGULATORY COMMISSION

?(.

h), %$

+

REasoNIv 0

611 RY AN PL AZA DRIVE. SUITE 400

5 AR LINGTON. T E XAS 76011-8064 9 *****

May 15,1998 G. R. Horn, Senior Vice President of Energy Supply Nebraska Public Power District 141415th Street Columbus, Nebraska 68601 l

SUBJECT:

REGION IV EXAMINATION WRITING WORKSHOP

Dear Mr. Horn:

Region IV and Office of Nuclear Reactor Regulation staffs will conduct an Examination Writing Workshop in the Region IV Training Conference Room, starting at noon on Wednesday, July 22 through noon on Friday, July 24,1998. The workshop is designed to follow up on our May 1997 l

workshop. It will convey examination test item review techniques for operator licensing examinations, provide skill-building exercises in the presented techniques, and discuss potential changes in the final version of NUREG-1021, " Operator Licensing Examination Standards for Power Reactors," Revision 8.

You and members of your operations and training staffs are invited to attend this workshop. Our goal for the workshop is to provide a leaming experience for your staff, to provide opportunities to review examination materials, and to provide an opportunity to interact with regional and headquarters operator licensing staffs. The subject audience for this workshop is those members of your staff who will prepare and review your operator licensing examination submittals.

The location for this conference will be the Region IV Training Conference Room at the Region IV office, located at 611 Ryan Plaza Drive, Suite 400, Arlington, Texas,76011. Please notify Ms. Laura Hurley of my staff at (817)B60-8253 with the names and positions of your staff who plan to attend the workshop.

Some background information is enclosed, which supports our discussions of the fundamentals of examination question development. We request that aU attendees at the workshop familiarize themselves with this material prior to the beginning of the workshop. However, we will allow for some time to provide an overview and answer questions on the material.

i 1

9805260327 980515 F

PDR ADOCK 05000298 V

PDR E _ z-----

Nebraska Public Power District A draft agenda is enclosed. We look forward to meeting with your staff in July. If you have any questions, any comments on the agenda, or need additional information, please contact me at

[

(817)860-8159.

l Sincerely, John L. Pellet, Chief Operations Branch Division of Reactor Safety Encir.sures: As stated Docket No.: 50-298 License No.: DPR-46 cc w/ enclosure:

Leo Croteau, Nuclear Training Manager Nebraska Public Power District P.O. Box 499 Columbus Nebraska 68602-0499 John R. McPhail, Genera! Counsel Nebraska Public Power District P.O. Box 499 Columbus, Nebraska 68602-0499 J. H. Swailes, Vice President of Nuclear Energy Nebraska Public Power District P.O. Box 98 Brownville, Nebraska 68321 B. L. Houston, Nuclear Licensing and Safety Manager Nebraska Public Power District P.O. Box 98 i

Brownville, Nebraska 68321 Dr. William D. Leech MidAmerican Energy 907 Walnut Street P.O. Box 657 Des Moines, Iowa 50303-0657

Nebraska Public Power District Mr. Ron Stoddard l

Lincoln FJectric System l

1040 O Dreet P.O. Box 60%9 Lincoln, Nebracka 68501-0869 l

Randolph Wood, Director Nebraska Department of Environmental i

Quality P.O. Box 98922 l

Lincoln, Nebraska 68509-8922 l

Chairman Nemaha County Board of Commissioners l

Nemaha County Courthouse l

1824 N Street l

Auburn, Nebraska 68305 Cheryl Rogers, LLRW Program Manager Environmental Protection Section Nebraska Department of Health 301 Centennial Mall, South P.O. Box 95007 l

Lincoln, Nebraska 68509-5007 l

i R. A. Kucera, Department Director of Intergovernmental Cooperation Department of Natural Resources P.O. Box 176 Jefferson City, Missouri 65102 l

Kansas Radiation Control Program Director i

I

{

i l

^

l i

i

Nebraska Public Power District bec to DCD (IE42) bec distrib. by RIV:

Regional Administrator Resident inspector DRP Director DRS-PSB Branch Chief (DRP/C)

MIS System Branch Chief (DRPTSS)

RIV File Project Engineer (DRP/C)

Laura Hurley R. Gallo DOCUMENT NAME: R:\\_CNS'iCN515ft.imb To receive copy of document, indicate in box: "C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy RIV:C:OB j6 JLPellet/imb M 05ff98 V

OFFICIAL RECORD COPY

Nebraska Public Power District bec to DCD (IE42) bec distrib. by RIV:

Regional Administrator Resident inspector DRP Director DRS-PSB Branch Chief (DRP/C)

MIS System Branch Chief (DRPTSS)

RIV File Project Engineer (DRP/C)

Laura Hurley l

R. Gallo l

l

!G0007 DOCUMENT NAME: R:\\_CNS\\CN515ft.imb i

To receive copy of document, indicate in box:"C" = Copy without enclosures "E" = Copy with enclosures "N" = No copy RIV:C:OB J6 JLPellet/imb M i

05 # 98 V

OFFICIAL RECORD COPY

ATTACHMENT 1 REGION IV EXAMINATION WORKSHOP DRAFT AGENDA i

Wednesday 12:00 - 12:15 pm introductory remarks Ellis Merschoff Arthur Howell John Pellet 1

J Wednesday 12:15 - 2:00 pm Discussion of measurement concepts Dr. George Usova including: validity, levels of knowledge, level of difficulty, and sampling.

Wednesday 2:00 - 2:15 pm Break Wednesday 2:15 - 3:00 pm What is a " direct lookup" question Dr. George Usova and how to identify one during a review.

Wednesday 3:00 - 3:15 pm Break Wednesday 3:15 - 4:15 pm Discussion of proposed Revis:on 8 John Pellet security and reviewer restriction changes.

Wednesday 4:15 - 4:45 pm Question and answers from the day.

John Pellet

)

Wednesday 4:45 - 5:00 pm Day 1 closing remarks John Pellet Thursday 8:00 - 8:15 am Day 2 Opening Remarks John Pellet I

Thursday 8:15 - 9:00 am Discussion of " scrutable" examination John Pellet sampling methodology.

Thursday 9:00 - 9:30 am The difference between a " correct" John Pellet answer and a legally defensible, objectively demonstrable answer.

Thursday 9:30 - 10:00 am One review methodology for the John Pellet operating test tasks and questions.

Thursday 10:00 - 10:15 am Break Thursday 10:15 - 11:30 am Group review of potential test items.

Thursday 11:30 - 12:30 pm Lunch Thursday 12:30 - 1:30 pm Workshop discussion of tasks and John Pellet questions. w _ - - _- -- - ----

Thursday 1:30 - 2:00 pm One review methodology for written John Pellet test questions.

Thursday 2:00 - 2:15 pm Break Thursday 2:15 - 4:00 pm Group review of proposed test items.

Thursday 4:00 - 4:45 pm Workshop discussion of written test John Pellet items.

l Thursday 4:45 - 5:00 pm Day 2 Closing Remarks John Pellet Friday 8:00 - 8:30 am Opening Remarks and questions and John Pellet answers from Day 2.

Friday 8:30 - 10:00 am Proposed changes in finalissue of John Pellet Revision 8 to NUREG-1021.

Applications and eligibility Test development 1

Test administration Post exam process Friday 10:00 - 10:15 am Break Friday 10:15 - 10:30 am Examination scheduling John Pellet Friday 10:30 - 11:15 am Questions and Answers John Pellet Friday 11:15 - 11:30 am Closing Remarks Ellis Merschoff Arthur Howell John Pellet i

i l l

---j

ATTACHMENT 2 THE NRC WRITTEN EXAMINATION:

PRINCIPLES AND PRACTICES Dr. George M. Usova USNRC Training and Assessment Specialist 301-415-1064 SESSION OBJECTIVE:

To review validity concepts affecting the NRC written examination for the purpose of:

instructing facility personnel toward the construction of more valid and consistent NRC license examinations COVERAGE o 3 Levels of Validity e 3 Levels of Knowledge

  • Discrimination, Sampling, and Cut Scores j

e Psychometrics i

VALIDITY A valid test is one which tests what it intends to test.

In training examinations, this means it tests the specific skills and knowledge defined and taught in the objectives.

In licensing examinations, this means it tests the specific skills and knowledge that should have been defined and taught in the objectives.

3 LEVELS OF VALIDITY Content

+

Operational Discriminant

+

1-

CONTENT VALIDITY Essentially addresses K/A coverage and sampling plan coverage I

OPERATIONAL VALIDITY Addresses two questions:

1.

Is the question, as stated, important to be known as a part of the operator's job?

2.

Does the question, as expressed, require the candidate to perform a job related mental or physical operation?

DISCRIMINANT VAllDITY Addresses making a distinction of measurement along a continuum of candidate performance.

The cut score is the exam performance level that the test yields for making a pass-fail decision.

Since the cut score is 80 percent, the exam must be written at a level of difficulty that intends to discriminate at the 80 percent level.

The test item, its stem and distractor, interplay are such that, by intent and design, at least 80 percent of the candidates taking the test should answer the item correctly.

VALIDITY

SUMMARY

1.

The exam (item) must be content valid, which encompasses job safety significance and sampling.

2.

The exam (item) should be operationally oriented: a conceivable mental or psychomotor performance of the job. As such the item should be written at the comprehension or analysis level vice simple fundamental knowledge; this means items that rneasure problem solving, prediction, and analysis-central to job performance.

3.

The exam (item) must discriminate at a moderate level of difficulty as set by the cut score. This means that the stem and distractor interplay are such that at least 80 percent of the candidates taking the test should answer the item correctly. - _ _ - _ _ _ _ _ _

3 LEVELS OF KNOWLEDGE Bloom's Taxonomy Analysis, Application, Synthesis

+

Comprehension

+

Fundamental (simple memory)

+

LEVEL OF KNOWLEDGE Bloom's Taxonomy is the reference benchmark NRC uses to classify the levels of

+

knowledge of test items.

Bloom's Taxonomy is a classification scheme that permits the classification of items by

+

the level (depth) of mental thought and performance required to answer the items.

Bloom's Taxonomy conceptually can be applied to written, scenarios, or JPM items.

LEVELS DEFINED LEVEL 1 Fundamental Knowledge testing is defined as a simple mental process that tests the recall or recognition of discrete information bits with concrete referents; examples include knowledge of terminology, definitions, set points, or other specific facts.

LEVEL 2 Comprehension testing involves the mental process of understanding the material through relating it to its own parts or to some other material; examples can include rephrasing information in different words, describing or recognizing re!ationships, showing similarities and differences among parts or wholes, recognizing how systems interact, including consequences or implications.

LEVEL 3 Analysis, synthesis, and application testing is a more active and product-oriented testing which involves the multi-part mental process of assembling, sorting, or integrating the parts (information bits and their relationships) so that the whole, and the sum of its parts can be used to: predict an event or outcome, solve a problem, or create something new, i.e., mentally using the knowledge and its meaning to solve problems. L_---______------.__----------..----

(_ _ __

DETERMINANTS OF DISCRIMINATION Level of examination knowledge Level of examination difficulty Passing score item bank use NATURE OF EXAMINATIONS AND TESTS Tests are samples of performance Infer overall performance based upon sample Sample must be broad-based to make confident inference Sample must not be fully predictable otherwise inferences cannot be made on untested areas ltems must intend to discriminate otherwise test has little or no value PSYCHOMETRICS ltems may have one or more of the following psychometrics errors:

1. Low level of knowledge (fundamental knowledge)
2. Low operational validity (not clearly job operational)
3. Low discriminatory validity (too easy or too hard)
4. Implausible distractors
5. Confusing language or ambiguous questions
6. Confusing or inappropriate negatives in the question
7. Collection of true/ false statements
8. Backward logic LOW LEVEL OF KNOWLEQSE Which one of the following is powered from 4160 VAC Bus 1A7
a. RHR pump A*
b. RHR pump B
c. RHR pump C
d. RHR pump D,

I' l

LOW LEVEL OF KNOWLEDGE l

Select the full core display indication of a drifting control rod.

a. Red light *
b. White light
c. Blue light
d. Amberlight J

LOW LEVEL OF KNOWLEDGE t-l Concerning use of water as a fire extinguishing agent, SELECT the correct statement from the following:

a. Primary agent for extinguishing Class A fi;es and also effective on Class B and C fires *
b. Primary agent for extinguishing Class B fires band also effective on Class A and C fires
c. Primary agent for extinguishing Class A and B fires but not effective on Class C fires
d. Primary agent for extinguishing Class B and C fires but not effective on Class A fires LOW LEVEL OF KNOWLEDGE The following plant conditions exist:

l o RCP 2A tripped after running for 50 minutes.

o The RCP was restarted, but tripped within 15 seconds.

Which ONE of the following is the minimum required interval before the next attempt to start l

RCP 2A7 i

a.15 minutes

b. 30 minutes
  • l
c. 45 minutes j

_ d. 60 minutes j

j j

LOW OPERATIONAL VALIDITY i

l Under which one of the following conditions should the Shift Supervisor inform the shop l

steward?

a. initiation of a directed overtime request
b. Discipline action on a supervisory personnel
c. Medicalinjury of a contractor personnel
d. Personnel error by a bargaining unit member *

-5~~

l

While this may be related to a SS's job, it has nothing to do with nuclear safety and should not be included in an NRC examination.

LOW DISCRIMINATORY VALIDITY Which one of the following reactor water levels will initiate the RHR pumps?

a. Level 1 only*
b. Level 1 and 2 only
c. Level 1 and 2 and 3 only
d. Level 6 only This information should be known by 100% of all operators at all times and is of low discriminatory validity.

LOW DISCRIMINATORY VALIDITY The plant is recovering from a scram due to a spurious Group i isolation. The cause of the isolation has been repaired and preparations are being made to reopen the MSIVs. Reactor l

pressure is currently 825 psig and the main steam lines are being pressurized.

WHICH ONE (1) of the following represents the LOWEST main steam line pressure that will allow the MSIVs to be opened per procedure?

a. 625 psig
b. 675 psig*
c. 725 psig
d. 775 psig IMPLAUSIBLE DISTRACTORS Which of the following will cause the RHR pumps to start during a design basis LOCA?
a. Low drywell pressure
b. High reactorwaterlevel
c. High drywell pressure *
d. MSIVs in the NOT OPEN position Distractors a, b, and d are implausible distractors considering minimal knowledge of the plant response to a LOCA. -

______.._____...___________.__m__

_____.____m

__.m..

____i ___.____

____..__-___-__.____-_.._______._m._

m._-_.-.

___m_._m

CONFUSING OR INAPPROPRIATE NEGATIVES IN THE QUESTION Regarding temporary plant alterations (TPA), technical reviews are NOT required

a. for a TPA NOT installed using an approved procedure.
b. for TPAs installed on BOP systems but are required for safety related systems.
c. for a TPA that has NOT been directed by the shift supervisor to be an emergency TPA.
d. for all TPAs directed by the shift supervisor.

This question contains multiple problems: (1) While negative questions can be used, they should be used for good reason; in the above example, there appears to be no good basis for asking this question negatively. (2) Two of the distractors (a and c) also contain a negative, creating a double negative and readability confusions, a violation of good item writing practice.

This question would be more appropriately written as "Under which of the following conditions are technical reviews required?" This phrasing would eliminate the negativ$ F: the stem.

COLLECTIONS OF TRUE/ FALSE STATEMENTS Which of the following are true?

a. High drywell pressure will auto start the emergency diesel generators.*

l

b. Low reactor water level will trip the main turbine.
c. High reactor pressure willinitiate RCIC.
d. High reactor power with the mode switch in startup will NOT close the MSIVs.

COLLECTIONS OF TRUE/ FALSE STATEMENTS Which one of the following describes pump cavitation?

a. Vapor bubbles are formed when the enthalpy difference between pump discharge and a pump suction exceeds the latent heat of vaporization.
b. Vapor bubbles are formed in the eye of the pump and collapse as they enter higher pressure regions of the pump.*

j

c. Vapor bubbles are produced when the localized pressure exceeds the vapor pres.sure at the 1

existing temperature.

l

d. Vapor bubbles are discharged from the pump where they impinge on downstream piping and i

cause a water hammer.

l Both examples represent an error of a collection of true/ false statements, which typically only j

l test simple rote memory; the candidate needs only to recall a definition or~ condition. The 1

i question elicits no comprehension or problem-solving; hence, the question lacks operational validity. This type of question allows a candidate to answer the question without the stem of the question..

1 BACKWARD LOGIC Which of the following parameters will simultaneously start HPCI, RCIC and SBGTS7

a. High RPV water level
b. High drywell pressure *
c. Low RPV water level 1
d. Low drywell pressure It is better to select a parameter and then request the expected system response because that is more operationally relevant.

BACKWARD LOGIC Backward logic is a question that asks the candidate for information normally received, and provides the candidate with information he/she normally has to supply. In an operational setting, operators are faced with conditions and required to know what procedure (s) to use. Instead the question asks them to do just the opposite.

BACKWARD LOGIC - an everyday example "If it takes 12.5 cubic feet of concrete to build a square leading pad 6 inches thick, what is the length of one side of the pad?"

This question gives the test takers information they should be asked to calculate, while it requires them to provide information they would be supplied in an actual work situation.

l 8-