.. - _

/, _. v) C:mm:nwIcith Edison -

i_ y 72 West Adams Street, Chicago, Illinois y

.\\ ] Address Reply to: Post OTfice Box 767 p

' Ns. : Chicago, Illinois 60690 0767

{

l.

i May 16,'1989 Dr. Thomas E. Murley, Director

-)

Office-of Nuclear. Reactor Regulation l

.U.

S.. Nuclear Regulatory Commission Washington, DC 20555

.I

Subject:

Byron Station Units 1 and 2 Braidwood Station Units 1 and 2 Leak-Before-Break Evaluation for Carbon Steel Piping NRC Docket Nos. 50-454/455 and 50-456/457 l

Dear Dr. Murleys 1

The purpose of this letter is to provide the Leak-Before-Break (LBB) evaluation.for carbon steel piping for Byron and Braidwood Stations. A meeting was held with members of your staff on May 3, 1989. During the

' meeting, Commonwealth Edison presented the LBB program for carbon steel piping systems that included the main steam line inside containment. The report-contained'in Attachment A provides the detailed evaluation.

Commonwealth Edison requests espproval of the LBB program for carbon steel piping.

j Please. direct any questions on this matter to this office.

Very truly yours, R. A.

hrzanowski Nuclear Licensing Administrator 0138T21 cc Byron Resident Inspector Braidwood Resident Inspector L. N. Olshau - NRR opl S. P. Sands - NRR M. C. Parker - IDNS f