Amend 63 to License NPF-29,changing Tech Spec Table 1.2, Operational Conditions & Tech Spec 3/4.9.1, Reactor Mode Switch, to Allow Movement of Single Control Rod W/Reactor in Hot or Cold Shutdown for Venting of CRD
ML20247K185
Person / Time
Site: Grand Gulf 
(NPF-29-A-063, NPF-29-A-63)
Issue date: 09/15/1989
From: Adensam E
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20247K190 List:
References
NUDOCS 8909210103
Download: ML20247K185 (5)


Text

--

9 AR IIGO

'o, UNITED STATES

.8'

~"i NUCLEAR REGULATORY COMMISSION h

*e WASHINGTON, D. C. 20555 o

%...../

SY'$ TEN. ENERGY. RESOURCES.INC...et al.

00CKET N0. 50-416 GRAND. GULF. NUCLEAR. STATION. UNIT.1 AMENDNENT.TO. FACILITY.0PERATING. LICENSE Amendment No. 63 License No. NPF-29 1.

The Nuclear Regulatory Comission (the Comission) has found that A.

The application for amendment by System Energy Resources, Inc.,

(the licensee), dated May 8,1989, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.-

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

Thereisreasonableassurance-(1)thattheactivitiesauthorizedby this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

f[2ggg{,] %

P

t 2-2.

Accordingly, the license is amended by changes to the Technical Specifications, as indicated in the attachment to this license amendment; I-and paragraph 2.C.(2) of Facility Operating License No. NPF-29 is hereby amended to read as follows:

(2) Technical. Specifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No. 63, are hereby incorporated into this license. System Energy Resources, Inc. shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION I

Original signed by LKintner for Elinor G. Adensam, Director Project Directorate 11-1 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of. Issuance:

September 15, 1989

...,............ 4. k. f.'

.)),..

DRPR: OGCL/
D-
DRPR :

OFC :LA:PD21:DRPR:PM:

g.....:..

NAME nderson :

er:sw:

  • EAdensam DATE.:09/.[....___:__.__...__..:___.....____....._____..:_________...:_________...:__

/89...:09/J/89....:09/.$/89..709/1./89...:

OFFICIAL RECORD COPY

l i

ATTACWMENT.TO. LICENSE. AMENDMENT.N0. 63..

l 1

FACILITY.0PERATING. LICENSE.NO..NPF.29

/

DOCKET.N0. 50-416 i

Replace the following Jages of the Appendix "A" Technical Specifications with the attached pages. Tie revised pages are identified by Amendment number and contain vertical lines indicating the area of change.

Remove Insert 1-11 1 11 3/4 9-1 3/4 9-1 1

4.yf ( ;

C

. TABLE 1.2 OPERATIONAL CONDITIONS MODE SWITCH AVERAGE REACTOR CONDITION-POSITION COOLANT TEMPERATURE-

1.. POWER OPERATION Run Any temperature 2.

STARTUP Startup/ Hot Standby.

Any. temperature 3.

HOT SHUTDOWN Shutdown #'***

> 200 F 4.

COLD SHUTDOWN.

Shutdown #*##'***

1 200 F 5.

REFUELING

  • Shutdown.or Refuel ***#

1 140 F i

'#The reactor mode switch may be placed in the Run or Startup/ Hot Standby position to test the switch interlock functions provided that the control rods'are verified to remain fully inserted by a second licensed operator or other technically qualified member of the unit technical staff.

    1. The reactor mode switch may be placed in the Refuel position while a single control rod drive is being removed from the reactor pressure vessel per Specification 3,3.10.1.

Fuel in the reactor vessel with the vessel head closure bolts less than fully tensioned or with the head removed.

See Special Test Exceptions 3.10.1 and 3.10.3.

The reactor mode switch may be placed in the Refuel position while a single

{

control rod is being moved provided that the one-rod-out interlock is l

1 OPERABLE.

J 4

GRAND GULF-UNIT 1 1-11 Amendment No.63

.. ?

.t 3/4.9 REFUELING OPERATIONS 3/4.9.1 REACTOR MODE SWITCH-LIMITING CONDITION FOR OPERATION 3.9.1 The reactor mode' switch shall be OPERABLE and locked in the Shutdown or Refuel position.

When the reactor mode switch is locked in the Refuel position:

a.

A control rod shall not be withdrawn unless the Refuel position one-rod-out interlock' is OPERABLE.

b.

CORE ALTERATIONS shall not be performed using equipment associated with a Refuel position interlock unless at least the following associ-ated Refuel position interlocks are OPERABLE for such equipment.

1.

One-rod-out.

2.

Refuel platform position.

3.

Refuel platform main hoist fuel-loaded.

APPLICABILITY:

OPERATIONAL CONDITION 5* #, OPERATIONAL CONDITIONS 3 and 4 when the reactor mode switch is in the Refuel position.

ACTION:

a.

With the reactor mode switch not locked in the Shutdown or Refuel position as specified, suspend CORE ALTERATIONS and lock the reactor mode switch in the Shutdown or Refuel position.

b.

' Wii5 the one-rod-out interlock inoperable, lock the reactor mode switch in thi. Shutdown position.

With any of the above required Refuel position equipment interlocks c.

inoperable, suspend CORE ALTERATIONS with equipment associated with the inoperable Refuel position equipment interlock.

1

  • See Special Test Exceptions 3.10.1 and 3.10.3.##
  1. The reactor FSall be maintained in OPERATIONAL CONDITION 5 whenever fuel is in the reacto vessel with the vessel head closure bolts less than fully tensioned or with the head removed.
    1. The reactor mode switch may be placed in the Run or'Startup/ Hot Standby position to. test the switch interlock functions provided that all control rods are verified to remain fully inserted by a second licensed operator or other technically qualified member of the unit technical staff.

GRAND GULF-UNIT 1 3/4 9-1 Amendment No.63

-