SAFETY EVALUATION EY THE OFFICE OF NUCLEAR REACTOR REGULATI0f:

Op OMAHA PUCLIC POWER DISTRICT FORT CALHOUN STATION, UNIT NO. 1 GENERIC LETTER 83-28, ITEMS 4.5.2 AND 4.5.3

~

REACTOR TRIP RELIABILITY FOR ALL DOMESTIC OPERATINC PEACTORS

1.0 INTRODUCTION

1 On February 25, 1983, both of the scram circuit-breakers at Unit I of the Salem Nuclear Power Plant failed to open upon an automatic reactor trip signal from the reactor protection system. This incident was terminated manually by the operator about 30 seconds after the initiation of the automatic trip signal. The failure of'the circuit breakers was determined tc be related to the sticking of'the undervoltage trip attachment. Prior to this. incident, on February 22, 29E3, at Unit 1 of the Salem Nuclear Power Plant, an automatic trip signal was generated based on steam generator low-low level during plart startup. ' In this case, the reactor was tripped manually by the opcretor almost coincidentally with the automatic trip.

Following these incidents,. on February 28, 1983, the NRC Executive Director forOperttions(EDO),directedthestafftoinvestigateandreportonthe generic implications of these occurrences at Unit I of the Salem Nuclear Power Plant. The result of the staff's inquiry into the generic implications of the Salem, Unit 1 incidents are reported in fiUREG-1000 "Gereric Implications of the AfWS Events at the Salem Nuclear Power Plant". As a result of this investigation, the Commission (NRC) requested (by Generic Letter (GL) 83-28.

dated July 8,1983) all licensees of cperating reactors, applicants for an operating license, and holders of construction permits to respond to generic issues raised by the analyses of these two ATWS events.

The licensee was required by GL 83-28, Items 4.5.2 and 4.5.3 to confirm that on-line functional testing of the reactor trip system, including independent testing of the diverse trip features, was being performed on all plants.

Existing intervals for on-line functional testing required by Technical Specifications were to be reviewed to determine that the intervals are censistent with achieving high reactor trip system availability when accounting for considerations such as: (1) uncertainties in component failure rates; (2) uncertainties in common mode failure rates; (3) reduced redundancy during testing; (4) operator error during testing; and (5) component " wear-out" caused by the testing.

C P

P

____-______-_____-_-_______--__-_Q

l l 2.0 DISCUSSION i

l The NRC staff requested the Idaho National Engineering Laboratory (INEL) to i

review the licensee's responses and also to review the considerable licensee Owners Group availability analyses and evaluate that on line functional testing can be performed at Fort Calhoun, and the adequacy of the existing test intervals with a consideration of the above five items for all plants. The results of these reviews are reported in detail in EGG-NTA-7463 "Ccnformance to 4.5.2 of Generic Letter 83-28", dated March 1987 and in EGG-NTA-8341, "A Review of Reactor Trip System Availability Analyses for Generic Letter 83-28, Item 4.5.3 Resolution" dated March, 1989.

These are sumarized in this report. The following is the results of our evaluation of Items 4.5.2 and 4.5.3 and cur review of EGG-NTA-7463 and EGG-NTA-8341.

In assessing GL 83-28 Item 4.5.2 for Fort Calhoun, the licensee states that they perform on-line testing of the reactor trip system and that the Fort Calhoun design uses four independent contactors instead of reactor trip breakers.

Each of these contactors can be independently tested at power which meets the requirements of GL 83-28 Item 4.5.2 for Combustion Engineering plants.

With respect to GL 83-28 Item 4.5.8, the Babcock & Wilcox, Combustion Engineering, General Electric, and Westinghouse Owners Groups have submitted topical reports either in response to GL 83-28, Item 4.5.3 or to provide a basis for requesting RTS surveillance test interval (STI) extensions. The owners groups' analyses addrased the adequacy of existing intervals for on-line functional testing of RTS with the considerations required by Item 4.5.3 by quantitatively estimating the unavailability of the RTS. These analyses found that the RTS was very reliable and that the unavailability was dominated by comen cause failure and human error.

The ability to accurately estimate unavailability for very reliable systems was considered extensively in NUREG-0460,

" Anticipated Transient Without Scram for Light Water Reactors", and the ATWS rule making. The uncertainties of such estimates are large, because the systems are so reliable, so little experience i

exists to support the estimates and because comon cause failure probabilities are difficult to estimate. We therefore believe that the RTS unavailability estimates in these studies, while useful for evaluating test intervals, must be used with caution.

NUREG-0460 also states that for systems with low failure probability such as the RTS, comon mode failures will have a tendency toward predominance, and for a number of reasons, additional testing will not appreciably lower RTS unavailability.

First, testing more frequently than weekly is generally impractical, so that increased testing could at best lower the failure i

prcbacility by less than a factor of four compared to monthly testing.

Secondly, increased testing could possibly increase the probability of a common mode failure through increased stress on the system. Thirdly, not all potential failures are detectable by testing.

In sumary, NUREG-0460 provides additional justification to demonstrate that the current monthly test intervals are adequate to maintain high RTS availability.

J

1 As t;

i a

3.0 CONCLUSION

The staff finds that_the Fort Calhoun Station, Unit 1 is_ designed to permit on-line function testing of-the reactor trip system and that the Fort Calhoun design permits independent _ testing of the trip contactors which meets the i

staff position of Item 4.5.2 of Generic Letter 83-28.

In responding to Item 4.5.3, all four vendors' topical reports have shown the currently configured RTS to be highly reliable with the current monthly test intervals.

INEL has reviewed these analyses and performed independent estimates of their own which conclude that the current test intervals provide high reliability._ In addition, the analyses in NUREG-0460 have shown that for a number of reasons, more frequent testing than monthly will not appreciably lower the estimates of failure probability.

Based on our review of the Owners Group topical reports, the review of this L

work and independent analysis by INEL and the findings noted in NUREG-0460, we l

conclude that the existing intervals for on-line functional testing are consistent with achieving high reactor trip system availability at all operating reacters.