Northem States Power Company f N Monticello Nuclear Generating Plant 2807 West County Road 75 Monticello, MN 55362 May 6,1998 U S Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 MONTICELLO NUCLEAR GENERATING PLANT Docket No. 50-263 License No. DPR-22 1998 Update on ASCO Scram P; lot Valve Diaphragm Issue Ref.1 Letter from W J Hill, NSP, to NRC Document Control Desk, " Transmittal of Plan on Interim Recommendations of BWR Owners' Group Regulatory Response Group Regarding Viton CRD SSPV Response Time Delay", May 10,1996.

By letter dated May 10,1996 (Ref.1), Northern States Power (NSP) communicated to the NRC our intentions regarding the Scram Solenoid Pilot Valve (SSPV) diaphragm material issue identified in NRC Information Notice 96-07. In that letter, NSP made the following commitment:

CRD SSPV Viton diaphragm performance will be monitored in accordance with the BWROG recommendations until a long term solution is implemented.

During Monticello's 1998 refueling outage, all remaining SSPV Viton A diaphragms were replaced with the new Viton 515AB material developed and qualified by General Electric (GE).

This fulfills the above 1996 commitment. However, to ensure this new material continues to function as intended, NSP intends to continue testing the CRDs per the BWROG's recommendations until we are satisfied with the diaphragm's performance. Therefore, NSP commits to the following:

NSP will continue to monitor the CRD scram times in accordance with the BWROG recommendations until satisfactory performance has been established.

Please contact Sam Shirey at 612-295-1449 if you have any questions related to this submittal.

b

\\Q Michael F. Hammer Plant Manager p g Monticello Nuclear Generating Plant (T

$/6/98 SIS J i \\ LICENSE \\NRCCOPD \\SS PV- $ 98. [CC 9805210197 990506 PDR ADOCK 05000263 G