ML20247G944

From kanterella
Jump to navigation Jump to search
Forwards Revised heat-up & Cooldown Curves & Replacement Pages to WCAP-11941 & Revised Curves Adjusted for Instrument Error & Containing Minor Labeling Changes Re 890419 Application for Amend to Licenses NPF-35 & NPF-52
ML20247G944
Person / Time
Site: Catawba  
Issue date: 09/13/1989
From: Tucker H
DUKE POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20247G950 List:
References
NUDOCS 8909190173
Download: ML20247G944 (3)


Text

___

~$7 5

4 1

~ NE j-b

"?bdwi I'

-g-p'*,"

. DUKE POWER GOMPANY -

p r.o. mox aates lL CHARLOTTE, N.G. 28242

HAL B. TUCKER m EPHONE

,A wornum emonomsom..

(704) 373-4531

. vmm ramenarn?

September 13,.1989; I

LU. S. Nuclear Regulatory Commission Document Control-Desk I,

-Washington, D.C.

20555

Subject:

. Catawba Nuclear Station.

Docket Nos.'50-413 and 50-414 Reactor Vessel Pressure - Temperature Limits My letter of April.19, 1989 transmitted a proposed license amendment to revise Jheat-up and cool-down limitation curves for Catawba Unit 1 and Unit 2 Technical Specifications.

It has-since been discovered that an error was made regarding the material properties of;the reference weld.in the Westinghouse analysis. Westinghouse has provided revised heat'-up and cooldown curves and replacement pages to WCAP 11941

(

(See Attachment 1). We'are, therefore, submitting revised curves which have been l

adjusted for instrument error and contain minor labeling ~ changes.

(Attachment-2).

Please contact L. T. Burba at (704) 373-2627 if there are further questions or comments.

..Very truly your,

.w.

Hal~B Tucker (j LTB17/lcs i

Attachment xc:

Mr.-S. D. Ebneter M & M Nuclear Consultants Regional Administrator 1221 Avenue of the Americas U. S. Nuclear Regulatory Commission New York, New York 10020 Region II 1,

-101 Marietta Street, NW, Suite 2900 INPO Records Center Atlanta, Georgia 30323 Suite 1500 1100 Circle 75~ Parkway

-n

.Mr. Heyward Shealy, Chief Atlanta, Georgia 30339

8 g

- o a_ -

Bureau of Radiological Health South Carolina Department-Mr. W. T. Orders of Health & Environmental Control NRC Resident inspector 2600 Bull Street Catawba Nuclear Station 9d!

Columbia, South Carolina 29201 t-o OQ 9"I American Nuclear Insurers l

5 Dottie Sherman, ANI Library

. R[j.

The Exchange, Suite 245 g

' O.VL O_

'270 Farmington Avenue

Farmington, CT 06032

= - _ _ _ __ __.

m ?-

{} ATT-1.-

}

i f

Westinghouse Energy Systems Box 355 Electric _ Corporation emsovan pennsylvania 1523c.0355 DCP-89-604 August 9, 1989 MT-SMART-138_(89)

P.O. J-22659-74 Mr. Robert L. Gill, Jr.

CH-14459 Duke Power Company P.O. Box 33189 Charlotte, NC 28242 Attention: Mrs. L. Burba DUKE POWER COMPANY Catawba Nuclear Station Unit 2 Reactor Vessel Surveillance Capsule Z Analysis Report WCAP-11941 - Revised Pace 1

Dear Mr. Gill:

As di cussed with you during our telecons of August 4, 1989 and August 8, attached are the revised pages of WCAP-11941 entitled, " Analysis of Capsule Z from the Duke Power Company Catawba Unit 2 Reactor Vessel Radiation Surveillance Program.

These revisions.to the heatup and cooldown curves are due to an inadvertent error.in our selection of material properties for the controlling reactor vessel material. The data points used to revise the heatup cooldown curves are also attached.

Please replace the attached pages in your copy of_ WCAP-11941.

We thank you for alerting us of our error and please accept our apology for any inconvenience you have experienced.

If there are any other questions or if you require additional information, please call me at 412-374-3333.

Very truly yours, WESTINGHOUSE ELECTRIC CORPORATION

$0bbYI C-p Duke Power Projects Sharon S. Kilborn, Project Manager

/sg

a DCP-89-604 Mr. R.

L.- Gill, Jr. August 9, 1989 cc:

R. L. Gill IL, IA L. Burba IL, IA D. ' E. Colson IL, IA S. E. Lawson IL T. R. Puryear IL, IA

- _ _.