ML20247F415
| ML20247F415 | |
| Person / Time | |
|---|---|
| Issue date: | 02/28/1989 |
| From: | NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES) |
| To: | |
| References | |
| TASK-CE-306-4, TASK-RE REGGD-03.061, REGGD-3.061, NUDOCS 8907270147 | |
| Download: ML20247F415 (39) | |
Text
- _. _
U.S. NUCLEAR REGULATORY COMMISSION February 1989 O @?oucoq\\s+$',i REGULATORY GUIDE
/
OFFICE OF NUCLEAR REGULATORY RESEARCH REGULATORY GUIDE 3.61 (Tesk CE.306-4)
STANDARD FORMAT AND CONTENT A
FOR A TOPICAL SAFETY ANALYSIS REPORT FOR A
(
SPENT FUEL DRY STORAGE CASK s
1 1
USNRC REGUIATORY GUIDi'S The guides are issued in the following ten troad divisions:
Regulatory Guides are issued to describe and make available to the pub-lic methode acceptable to'the NRC staff of implementing specific parts of the Commission's regulations, 'to delineate techniques used by the
- 1. Power Reactors
- 6. Products staff in ava uating specific problems or postulated accidente, or to pro-
- 2. Research and Test Reactors
- 7. Transportation vide gu6 dance to applicants. Regulatory Guides are not substitutes for
- 3. Fuels and Materials Facilrties B. Occupational Health regulations, and comphance with them is not required. Methods and
- 4. Environmental and Siting D. Antitrast and Financial Review solutions different from those set out in the guides will be acceptable If S. Materials and Plant Protcction
- 10. Gerieral they provide a basis f Jr the findings requisite to the issuance or continte-ance of a pr mit or Ocense by the Commission.
Copies of WW pdos may be purchased from the Government Printing
[
This guide was issued after consideration of comments received from Office at the cutrent GPO price. pitormation on current GPO prices may g
the public. Comments and suggestions for improvernents in these le obtained by contacting the Superintendent of upr uments. U.S.
\\
guides are encour60ed at all times, and guides will te revtsed, as ap Government Printing Office. Post Office Don 37082 Washington, DC propriate, to accommodate comments and to reflect new information or 20013-7082, telephone (202)275-2000 or (2021275-2171, experience.
Written comments rnay be submitted to the Regulatory Publications issued pulces may also be purchased from the National Technical infor-Dranch. DFtPS, ARM, U. 6. Nuclear Regulatory Commission. Washing-mation Service on a standing order basis. Details on tnis service may te ton, DC 20555.
cbtained by writinD NTIS 5285 Port Roval Road, Spongfield, VA 22161.
8907270147 090229 PDR REGCD 03.061 R PDR
O)
TABLE OF CONTENTS
,v Page 1
l INTRODUCTION.............................
v CHAPTER 1 GENERAL DESCRIPTION....................
3.61-1 1.1 Introduction.....,..................
3.61-1 1.2 General Description of the Storage Cask 3.61-1 1.3 Identification of Agents and Contractors..........
3.61-2 1.4 Generic Cask Arrays 3.61-2 1.5 Supplemental Data 3.61-2 CHAPTER 2 PRINCIPAL DESIGN CRITERIA 3.61-3 2.1 Spent Fuel To Be Stored 3.61-3 2.2 Design Criteria for Environmental Conditions and Natural Phenomena 3.61-3
- 2. 3 Safety Protection Systems 3.61-5 2.4 Decommissioning Considerations...............
3.61-6 CHAPTER 3 STRUCTURAL EVALUATION,,...
3.61-7 3.1 Structural Design 3.61-7 3.2 Weights and Centers of Gravity...............
3.61-7
(
3.3 Mechanical Properties of Materials.............
3.61-7
(./
3.4 General Standards for Casks 3.61-8 3.5 Fuel Rods 3.61-9 3.6 Supplemental Data 3.61-9 CHAPTER 4 THERMAL EVALUATION 3.61-10 4.1 Discussion.........................
3.61-10 4.2 Summary of Thermal Properties of Materials.........
3.61-10 4.3 Specifications for Components 3.61-10 4.4 Thermal Evaluation for Normal Conditions of Storage.....
3.61-10 4.5 Supplemental Data 3.61-11 CHAPTER 5 SHIELDING EVALUATION 3.61-12 5.1 Discussion and Results..
3.61-12 5.2 Source Specification.............
3.61-12 5.3 Model Specification 3.61-12 5.a Shielding Evaluation............
3.61-13 5.5 Supplemental Data 3.61-13 CHAPTER 6 CRITICALITY EVALUATION 3.61-14 0.1 Discussion and Results 3.61-14 6.2 Spent Fuel Loading....
3.61-14 6.3 Model Specification 3.61-14 l g]
N.l iii
i i
TABLE OF CONTENTS (Continued) 6.4 Criticality Calculation 3.61-14
- 6. 5 Critical Benchmark Experiments.........
3.61-15 6.6 Supplemental Data 3.61-15 CHAPTER 7 CONFINEMENT 3.61-16 i
7.1 Confinement Boundary....
3.61-16 7.2 Requirements for Normal Conditions of Stcrage........
3.61-16
- 7. 3 Confinement Requirements for Hypothetical Accident Conditions...
3.61-17 7.4 Supplemental Data........
3.61-17 CHAPTER 8 OPERATING PROCEDURES 3.61-18 8.1 Procedures for Loading the Cask.
?.61-18 3.61-18 8.2 Procedures for Unloading the Cask 8.3 Preparation of the Cask.
3.61-18 8.4 Supplemental Data..
3.61-18 CHAPTER 9 ACCEPTANCE CRITERIA AND MAINTENANCE PROGRAM.
3.61-19 9.1 Acceptance Criteria 3.61-19
- 9. 2 Maintenance Program 3.61-20 CHAPTER 10 RADIATION PROTECTION 3.61-22 10.1 Ensuring that Occupational Radiation Exposures Are As Low As Is Reasonably Achievable (ALARA)..
3.61-22 10.2 Radiation Protection Design Features 3.61-22 10.3 Estimated Onsite Collec ive bose Assessment 3.61-22 CHAPTER 11 ACCIDENT ANALYSES 3.61-24 J.61-24 11.1 Off-Normal Operations..
11.2 Accidents.
3.61-26 CHAPTER 12 OPERATING CONTROLS AND LIMlIS 3.61-28 12.1 Proposed Operating Controls and Lim m 3.61-28 12.2 Development of Operating Controls and Limits 3.61-28 3.61-31 CHAPTER 13 QUALITY ASSURANCE Value/ Impact Statement.
3.61-32 O
iv
A j'
INTRODUCTION U
Section 72.24, " Contents of Application:
Technical Information," of 10 CFR Part 72, " Licensing Requirements for the Independent Storage of Spent Nuclear Fuel and High-Level Radioactive Waste," specifies that a afety analysis report (SAR) must be included with an appli ation for a license under Part 77.
A safety evaluation specifically for the cask to be used for storing spent fuel must be provided in the SAR for an ISFSI license because the cask l
is important to safety.
i j
This regulatory guide provides guidance on the format and content of a topical safety analysis report (TSAR) for a spent fuel storage cask.
There is no regulation that requires the submittal of a TSAR fer spent fuel storage casks.
Ilowever, if a TSAR on a specific spent fuel storage cask is evaluated by the NRC staff and accepted for referencing in licensing actions, appropriate sections of the TSAR could be referenced in other submittals.
Applicants for a specific license under Part 72 cculd reference the appropriate information in their SAR, thus significantly reducing their time, effort, and costs.
Casks used for storage of spent fuel on a reactor site could be those used for shipping spent fuel or could be those designed for storage only.
Casks used for shipping must be licensed under 10 CFR Part 71, " Packaging and Trans-portation of Radioactive Material," which requires stringent quality assurance and cask testing.
Casks used for shipping could also be approved for storage of spent fuel if their safety is demonstrated.
Pt.rpose and Applicability Not all subjects identified in this regulatory guide may be applicable to a specific cask design, e.g., for casks with solid neutron shield material, guid-ance related to liquid shielding material and its retention. Additional or different subjects may be applicable to some cask designs.
The infor; nation identified represents the minimum that should be provided, recognizing that not all information requested necessarily applies to all specific dcsigns.
Additional information may be requested for NRC staff review of the TSAR.
If any changes in the cask design are made after submittal of the TSAR but before the NRC has completed its review, the TSAR should be updated.
This ensures that the TSAR as accepted for referencing reflects the actual cask l
design.
l The TSAR snould serve as the principal technical communication between the cask vendor and the NRC.
I? establishes the design of the cask and the plans for its use.
The TSAR should contain an analysis of the cask design in terms of poten-tial hazards and the means employed to protect against these hazards, including
[-
th.e associated margins of safety.
This includes evaluating:
1.
The cask's vulnerability to accidents during operations and from natural phenomena, O
2.
Radiation shielding, 3.
Confinement and control of radioactive materials, v
4.
Reliability of the systems that are important to safety, and 5.
The radiological impact associated with normal operations, off-normal conditions, and accidents.
}
The TSAR should demonstrate the degree of skill, care, and effort used in planning all aspects of the project.
A complete, in-depth analysis of all sub-jects in the report should ce provided.
l The TSAR should set forth a description, including all pertinent technical l
information, an ting its being withheld from public disclosure as specified by 6 2.790, "Public Inspections, Exemptions, Requests for Withholding," of 10 CFR Part 2, " Rules af Practice for Domestic Li:ensing Proceedings."
O vi
h Style and Composition (v)
To the e-tent possible, the TSAR should follow the numbering system of this Standard Format at least down to the level of subsections, e.g., 3.1.2 Design Criteria.
j 1
References, including author, date, and page number, should be cited within the text if important to the meaning of the statement.
References should appear either as footnotes to the page where referenced or at the end of each chapter.
1 A table of contents and an index of key items should be included in each volume of the TSAR.
For numerical values, the number of significant figures given should reflact the accuracy and precision to which the number is known. When appropri-ate, estimated limits of errors or uncertainty should be given.
Abbreviations should be consistent throughout the TSAR and should be con-sistent with generally accepted usage.
Any abbreviations, symbols, or special terms not in general usage or that are unique to the proposed cask design should be defined when they first appear in the TSAR.
Graphic Presentations Graphic presentations such as drawings, diagrams, sketches, and tables should be employed when the information may be presented more adequately or
(^%
conveniently by such means.
Due concern should be taken to ensure that all (j
informati6n so presented is legible, that symbols are defined, and that draw-
. ings are not 754/Jced tc the extent that visual aids are necessary to interpret pertinent items of information.
These graph.c presentations should be located in the section in.vhich they are primarily referenced.
Physical Specifications Paper size Text pages:
8-1/2 x 11 inches.
Drawings and graphics:
8-1/2 x 11 inches; however, a larger size is acceptable provided the finished copy when folded does not exceed 8-1/2 x 11 l
inches.
}
}
Paper stock and ink.
Suitable quality in substance. paper color, and ink
~
density for handling and reproduction by microfilming or image-copying equipment.
Page margins.
A margin of no less than 1 inch should be maintained on the top, bottom, and binding side of all pages submitted.
Printing Composition:
text pages should be single spaced.
(
\\\\
vii
Type face and style:
should be suitable for microfilming or image-copying equipment.
Reproduction: may be mechanically or photographically reproduced.
All pages of text should be printed on both sides with image printed head-to-head.
Binding.
Pages should be punched for standard 3-hole loose-leaf binders.
Page numbering.
Pages should be numbered with the digits corresponding to the chapter and first-level section numbers followed by a hyphen and a sequen-tial number within the section, e.g., tt:e third page in Section 4.1 of Chapter 4 should be numbered 4.1-3.
Do not number the entire report sequentially.
(Note that because of the small number of pages in this guide, this Standard format is numbered sequentially throughout.)
Procedures for Updating or Revising Pages Data and text should be updated or revised by replacing pages.
" Pen and ink" or " cut and paste" changes should not be used.
To avoid confusion between original and updated material, each TSAR supple-ment should be dated and identified by its supplement number in the lower right-hand corner of the page.
Each supplement should be accompanied by a supplement ind(<. also dated and numbered, listing pages to be inserted or removed.
The supp'iement index should identify pages containing new material by page number and the date of the new material.
i 1
1 O
viii
r
'k -
l 1.
GENERAL DESCRIPTION Present, in narrative style, the purpose for and a general description of the storage cask.
The information in this chapter should enable the reader to 1
obtain a basic understanding of the cask and the protection afforded the public health and safety without having to refer to the subsequent chapters.
This general description should enable the reader to follow the detailed chapters with better perspective and to recognize the relative safety importance of each individual item to the overall cask design.
1.1 Introduction Present briefly the principal design features of the cask.
Include a general description of the characteristics of the cask; the nominal capacity of the cask; and the type, form, quantity, and potential sources of the spent fuels to be stored.
- 1. 2 General Description of the Storage Cask 1.2.1 Cask Characteristics Summarize the principal characteristics of the cask.
Include the gross weight, materials of construction, materials used as neutron absorbers and
[
moderators, external dimensions and cav ty size, internal and external structures, i
receptacles, valves, sampling ports, means of passive heat dissipation, volume and type of coolant, outer and inner protrusions, lifting devices, impact limiters if applicable, amount of shielding, pressure relief systems (if appli-cable), closures, means of confinement, model number, and a description of how individual casks will be identified.
The confinement vessel should be clearly identified.
Overall and cutaway sketches of the package should be included as part of the description, If the cask is certified under 10 CFR Part 71, " Packaging and Transporta-tion of Radioactive Material," pertinent information shcald be provided in this sect'^n and details and copies of documents (drawings, etc.) referenced in the cask's Certificate of Compliance should be included in Section 1.5, Supplemental Data.
I l~
Drawings and specifications that clearly summarize the safety features considered in the analysis should be included in Section 1.5; for example, material lists, dimensions, and specifications for valves, gaskets, and welds should be included.
Detailed construction drawings should not be included.
1.2.2 Operational Features A discussion of anticipated operations involving the cafk should be pro-vided.
It should include a schematic diagram showing instrumentation, valves, connections, piping, openings, seals, confinement boundaries, etc.
This section
/'
should cos:tain a suggested procedure for using the cask.
The section should
(
also contain a discussion of the design bases considered for preventing or s tigating the consequences of potential human error.
3.61-1
1.2.3 Cask Contents State the type and quantity of radionuclides that may be stored in the cask.
Include the chemical and physical form, material density, moderator ratios, con-figurations required for nuclear safety, maximum amount of decay heat, maximum pressura buildup in the inner container, and any other loading restrictions.
Estimate the type and quantity of radionuclides available for release.
1.3 Identification of Agents anti Contractors Identify the prime agents or contractors for the design, fabrication, and testing of the cask.
All principal consultants and outside service organiza-tions, including those providing quality assurance services, should be identi-fied.
The division of responsibility between the designer and fabricator should be delineated.
1.4 Generic Cask Arrays Identify generic arrays of multiple casks in storage, such as in-line, square, vertical, and horizontal.
The information should be sufficient to enable an evaluation of a particular array with regard to thermal and radiologi-cal conditions both within the array and at site boundaries.
1.5 Supplemental Dcta This section should include detailed information describing the cask and its operational features and contents.
Include dimensional drawings, detailed operational schematics, and loading configurations.
1 9
3.61-2
2.
PRINCIPAL DESIGN CRITERIA Principal design criteria for the stor.ge cask should be presented in this section.
The bat _; for these criteria snould also be discussed.
The NRC staff analyzes these design criteria for adequacy in evaluating the cask TSAR.
Changes in the criteria are not anticipated after the TSAR is accepted for referencing.
Therefore, the criteria selected should encompass all considerations for design alternatives that the vendor may chotse.
2.1 Spent Fuel To Be Stored A detailed description of the physical, thermal, and radiological characteristics of the spent fuels that the cask is designed to store should be provided.
Include spent fuel characteristics such as initial enrichment, specific power, Surnup, decay time, and heat generation rates.
2.2 Design Criteria for Environmental Conditions and Natural Phenomena Identify and quantify environmental conditions and natural phenomena used for designing the cask, and identify those components of the cask that are identified as important to safety.
Meteorological conditions, flooding, seis-micity, ambient temperature range, and peak insolation shc.uld be considered, as appropriate.
Data and design assumptions should be included.
2.2.1 Tornado and Wind Loadings 2.2.1.1 Applicable Design Parameters.
The design parameters applicable 9
the design pressure differential as well as the associated time interval should to the design tornado such as transnational velocity, rotational velocity, and be specified.
Regulafory Guide 1.76, " Design Basis Tornado for Nuclear Power Plants," contains infsrmatinn that may by helpful.
2.2.1.2 Determination of Forces on Structures.
Describe the methods used to convert the tornado and wind loadings into forces on the cask, including the distribution across the cask and the combination of applied loaos.
If factored loads are used, the basis for selection of the load factor used for tornado loading should be furnished.
2.2.1.3 Tornado Missiles.
The dimensions, energy, velocity, and other parameters should be selected for a potential tornado-driven missile.* Ar.
analysis sbould be presented to show that the cask can withstand the impact of the missile without significantly impairing its confinement ability.
- Paragraph 4 in subsection Ill of Section 3.5.1.4, " Missiles Generated by Natural Phenomena," of NUREG-0800, " Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants," contains information that O
may be of value when developing these data.
A copy of this section is avail-able for inspection and copying for a fee at the NRC Public Document Room, 2120 L Street NW., Washington, DC, under file CE 306-4.
3.61-3
l l
l 2.2.2 Water Level (Flood) Design Discuss the applicability of effects from a probable maximum flood (PMF),
and, if applicable, discuss the design loads from forces developed by the PMC, including water height and dynamic phenomena such as velocity.
Reference the design criteria to PMF data.
2.2.2.1 Flood Elevations.
The flood elevations used in the design of the cask for buoyancy and static water force effects should be provided.
2.2.2.2 Phenomena Considered in Design Load Calculations.
The phenomena (e.g., flood current, wind wave, hurricane, or tsunami) considered if dynamic water force is a design load should be identified and discussed.
2.2.2.3 Flood Force Application.
Describe the mi mer in which the forces and other effects resulting from flood loadings are applied.
2.2.2.4 Flood Protection.
Describe the flood protection measures for cask components that are important to safety.
2.2.3 -Seismic Design Discuss the applicability of effects from seismic events, and, if applicable, discuss the seismic design bases used in the design and fabrication of the cask to establish the required parameters that envelop credible conditions ander which the cask may operate.
Sufficient detail should be presented to allow an i
independent evaluation of the criteria selected.
If necessary, the following format is suggested.
2.2.3.1 Input Criteria.
This section should discuss the input criteria for seismic design of the cask.
If response spectral shapes other than those in Regulatory Guide 1.60, " Design Response Spectra for Seismic Design of Nuclear Power Plants," are proposed for design of the cask, these should be justified and the earthquake time functions or other data from which these were derived should be presented.
For damping values that are used in the design, submit a comparison of the response spectra aeri,ed from the time history and the design response spectra.
The system period intervals at which the spectra values were calculated should be identified.
2.2.3.2 Seismic-System Analyses.
This section should discuss the seismic-system analyses applicable to cask components that are important to safety.
The following specific information should be included:
I 1.
Seismic Analysis hethods.
For all cask components that are important to safety, the applicable methods of seismic analysis should be identified.
Applicable descriptions (or sketches) of typical mathematical models used to determine the response should be specified.
2.
Methods to Determine Overturning Moments.
A descript <n of the dynamic methods and procedures used to determine cask overturning moments should be provided, including a description of the procedures used to account for vertical earthquake effects.
Establish the minimum overturning moment that could cause tipping of the cask.
3.61'
2.2.4 Snow and Ice Loadings Describe criteria used to ensure that the effects of snow and ice loads can be accommodated, particularly with respect to thermal and stress transients that may be induced.
l i
2.2.5 Combined Load Criteria For combined loads, describe the criteria selected to provide mechanical and structural integrity.
The loads and loading combinations to which the cask is designed should be defined, including the load factors selected for each load component in which a factored load approach is used.
The design approach used with the loading combination and any load factors should be specified.
The design loading combinations used to examine the effects on localized areas such as penetrations, structural discontinuities, and local areas of high thermal gradients should be provided., together with time-dependent loading such as tnermal effects, effects of creep and shrinkage, and other related effects.
2.3 Safety Protection Systems 2.3.1 General Identify special considerations in the design that may result from an evaluation of cask operating conditions (e.g., loading, unloading, transport) to ensure the long-term safety and confinement of the stored fuel.
2.3.2 Protection by Multiple Confinement Barriers and Systems 2.3.2.1 Confinement Barriers and Systems.
Discuss each method of confine-ment that will be used to ensure that there will be no uncontrolled release of radioactivity to the environment.
Include for each:
1.
Criteria for protection against any postulated off-norc;al operations, internal change, or external natural phenomena, 2.
Design criteria selected for backup confinement, and 3.
Delineation of the extent to which the design is based on achieving the lowest practical level of radioactive releases from the cask.
2.3.2.2 _ Cask Cooling.
Describe the criteria selected for providing suit-able passive c'ooling of the cask unaer normal and off-normal conditions.
2.3.3 Protection by Equipment and Instrumentation Selection 2.3.3.1 Equipment.
Design criteria for cask equipment that is important to safety should be provided.
This would include any equipment used to protect against or mitigate the effects of the release of redioective material.
2.3.3.2 Instrumentation.
Discuss the desigo bases and design criteria for instrumentation selected with particular emphasis on features to provide reliability and testability.
O 3.61-5
2.3.4 Nuclear Criticality Safety Supply pertinent design bases to show the appropriate safety margins that ensure that a suocritical situation exists under cil credible conditions.
2.3.4.1 Control Methods for Prevention of Criticality.
Present the methods to be used to unsure that subcritical situations are maintained in storage under the worst credible conditions.
2.3.4.2 Error Contingency Criteria.
To support the above information, define the error contingency criteria selected.
2.3.4.3 Vori fication Analyses.
Present the criteria for verifying models or computer programs used in criticality analyses.
Revision 2 of Regulatory Guide 3.4, " Nuclear Criticality Safety in Operations with Fissionable Materials at Fuels and Materials Facilities," provides information on this subject.
2.3.5 Radiological Protection Based on anticipated storage system operations, an estimate of collective doses (in person-rem) per year, including estimated collective doses associated with cask operation, maintenance, repair, and decommissioning, should be presented.
2.3.6 Fire and Explosion Protection Provide the design criteria selected to ensure that all safety functions will successfully withstand credible fire and explosion conditions.
2.4 Decommissioning Considerations Discuss the consideration given in the design of the cask to decommission-ing.
Examolas of subjects to be covered are (1) discussion of neutron activa-tion of the cask and fuel basket materials, (2) provisions for the decnntamina-tion and removal of potentially contaminated components, and (3) discussion of the decommissioning processes.
1 O
3.61-6
p I
\\
i A
)
3.
STRUCTURAL EVALUATION This chapter of the TSAR should identify, describe, discuss, and analyze the principal structural c.5ineering design of the cask's components and systems that are important to safety.
The design bases for design criteria should be discussed.
3.1 Structural Design i
3.1.1 Discussion Identify the principal structural members and systems that are important to safety, such as the confinement vessel and closure devices.
Reference the location of these items on drawings, and discuss their design and performance.
3.1.2 Design Criteria Describe the load combinations and factors that serve as design criteria.
For each of these criteria', state the maximum allowable stresses and strains (as a percentage of the yield or ultimate values) for ductile failure, and de-scribe how the other structural failure modes (e.g., brittle fracture, fatigue, buckling) are considered.
If different design criteria are to be allowed in various parts of the cask for different conditions, the appropriate values for each should be indicated.
Include the criteria that will be used for impact evaluation.
Identify all codes and standards that are used to determine mate-
/
rial properties, design limits, or methods of combining loads and stresses.
(
In cases of deviation from standard codes, or when certain components are not k
covered by standard codes, provide a detailed description of the design criteria used as substitutes for such codes.
3.2 Weights and Centers of Gravity Provide the total weight of the cask and contents.
Tabulate the weights of major individual subassemblies so that the sum of the parts equals the total of the cask.
Locate the center of gravity of the cask and any other centers of gravity referred tu in the application.
It is not necessary to include the calculations made to determine these values, but a sketch or drawing that clearly shows the individual subassembly referred to and the reference point for locating its center of gravity should be included.
2 3.3 Mechanical Properties of Materials e
Provide mechanical properties of materials used in the structural evalu-ation.
These may include yield stress, ultimate stress, modulus of elasticity, ultimate strain, Poisson's ratio, density, and coefficient of tnermal expansion If impact honiters are used, include either a compression stress-strain curve for the material or the force-deformation relationship for the limiter, as appropriate.
For materials that are subjected to dynamic loadings or elevated
' temperatures, the appropriate mechanical properties under these conditions should be specified to the extent used in the structural evaluation.
The source of all information in this section should be clearly and specifically
[~
referenced as to publication and page number.
If material properties were
't determined by testing, the test procedure, conditions, and measurements should 3.61-7
f 1
be described in sufficient detail to allow the staff to conclude that the resulto are valid.
3.4 General Standards for Casks 3.4.1 Chemical and Galvanic Reactions Discuss possible chemical, galvanic, or other reactions in the cack or between the cask and its contents.
For each component material of the cask, list all chemically or galvanically dissimilar materials with which it has contact.
Indicate any specific measures that have been taken to prevent contact or reaction between materials, and discuss the effectiveness of such measures.
3.4 2 Positive Closure Describe and discuss the cask cicsure system in sufficient detail to show that it cannot be inadvertently opened.
This demonstration should includa covers, valves, or any other access that must be closed during normal operation.
3.4.3 Lifting Devices Identify all devices and attachments that can be used to lif t the cask or its lid.
Show by testing or analysis that these devices, if structurally part of the cask, are capable of supporting three times the weight of the loaded cask without generating stress in any part of the cask in excess of its yield strength.
Provide drawings or sketches that show the location and construction of these items.
Determine the effects of the forces imposed by lifting on vital cask components, including the interfaces between the lifting devices and other cask surfaces.
Documented values of the yield stresses of the materials should be used as the criteria to demonstrate compliance with this section.
3.4.4 Heat The thermal evaluation for the cask should be reported in Section 4.4.
3.4.4.1 Summary of Pressures and Temperatures.
Summarize pressures and temperatures (deteimined in the thermal evaluation in Chapter 4) that will be used to perform the calculations required for Sections 3.4.4.2, 3.4.4.3, and 3.4.4.4.
3.4.4.2 Differential Thermal Expansion.
Calculate the circumferential and axial deformations and strasses (if any) that result from differential thermal expansion.
Consider steady-state and transient conditions.
These calculations must be sufficiently comprehensive to demonstrate cask integrity under normal operating conditions.
1 j
3.4.4.3 Stress Calculations.
Calculate the stress from the combined effects of thermal gradients, pressure, and mechanical loads.
Provide sketches or free body diagrams that show the configuration and dimensions of the members or systems being analyzed, and locate the points at which the stresses are being 3.61-8 l
1 calculated.
The analysis should consider whether repeated cycles of thermal f-loadings, together with other loadings,- will cause fatigue f ailure or extensive accumulations of deformation.
3.4.4.4 Comparison with Allowable Stresses.
Make the appropriate stress combinations and compare the resulting stresses with the design criteria in Section 3.1.2.
Show that all the requirements specified in the regulations have been satisfied.
3.4.5 Cold Assess the cask for the effects of a steady-state ambient temperature.
Consider both material properties and possible freezing of liquids under this condition.
For components of the cask that are important to safety, identify the resulting temperatures and the ways they affect the operation of the cask.
Brittle fracture sN uld be considered.
3.5 Fuel Rods When fuel rod cladding is considered in the design criteria for confine-ment of radioactive material under normal or accident conditions, provide an analysis or test results showing that the cladding will maintain its integrity.
Show that fuel rod assemblies can be handled during loading and unloading of the cask without compromising the confinement of radioactive materials.
3.6 Supplemental Data O
J This section should include information such as justifications of assump-
\\
tions or analytical procedures; test results; photographs; computer program descriptions, documentatica, benchmarks, and input / output; reference lists; and applicable pages from referenced documents.
?
) --
km 3.61-9
i.
4.
THERMAL EVALUATION This chapter of the TSAR should identify, describe, discuss, and analyze the thermal engineering design of the cask structures, components, and systems that are important to safety.
The bases for the design criteria should be discussed.
4.1 Discussion Describe the significant thermal design features and operating character-istics of the cask.
The operation of all subsystems (e.g., cooling systems, expansion tanks) should be discussed.
Summarize the significant results of the thermal analysis or tests and the implication of these results on the overall design.
State the minimum and maximum decay heat loads assumed in the thermal evaluation.
4.2 Summary of Thermal Properties of Materials List the thermal properties of all materials used in the thermal evalua-
' tion.
References for the data cited should be provided in Section 4.5.
4.3 Specifications for Components Include the specifications for cask components.
For example, in the case of relief devices or rupture discs, the operating pressure range and temperature limits should be included.
Data sh-ould be supplied in support of technical specifications and should be presented in detail in Section 4.5.
4.4 Thermal Evaluation for Normal Conditions of Storage 4.4.1 Thermal Model 4.4.1.1 Analytical Model.
Describe the analytical thermal model in detail.
The model should include data on gaskets, valves, fuel assemblies, and the over-all containment.
Modeling assumptions should be fully justified.
4.4.1.2 Test Model.
Describe the tests, models, and procedures used to correlate the E t data to the thermal environment for normal conditions.
Temperature data should be taken f rom gaskets, valves, confinement boundaries, and other areas of the cask.
4.4.2 Maximum Temperatures l
Provide the maximum temperature distribution for the cask for normal condi-l tions of storage, including the spent fuel, confinement vessel, shielding mate-rial, gaskets, valves, etc.
4.4.3 Minimum Temperatures Provide the minimum temperature distribution for the cask for riormal conditions of storage.
Inis evaluation should include the minimum decay heat load that will be experienced.
If a decay heat load greater than zero is O
3.61-10
i required for safe operation, assurance of that heat load must be provided.
9 The temperatures of significant components such as gaskets and valves should be reported.
4.4.4 Maximum Internal Pressures The conditions within the range of normal conditions of storage that result in the worst internal pressures or the worst combination of thermal 1
loadings should be identified.
The internal pressures for the conditions should be determined.
The evaluation should consider the effects of phase i
change, gas generation, chemical decomposition, etc.
4.4.5 Maximum Thermal Stresses Determine the conditions within the range of normal conditions of storage that result in the worst combination of thermal gradient and isothermal stresses.
Provide the resulting temperature distribution.
4.4.6 cvaluation of Cask Performance fc'r Normal Conditions of Storage Evaluate the c; performance, including system and subsystem operations, for normal conditions of storage with respect to the results of the thermal analyses or tests performed.
Take into account significant conditions to be found in the ranges bounded by the minimum and maximum ambient temperatures and minimum and maximum decay heat loads.
Compare the results with allowabie limits of temperature, pressure, etc., for the cask components.
Designate the Present the 9
information.that is to be used in other chapters of the TSAR.
information in summary tables along with discussions as appropriate.
4.5 Supplemental Data This section should include data in support of thermal evaluat'ons such as
. justifications of assumptions or analytical procedures; test results; photographs; computer program descriptions, documentation, benchmarks, and input / output; and applicable pages from referenced decuments.
t O
3.61-11
I i
5.
SHIELDING EVALUATION This chapter should identify, describe, discuss, and analyze the shielding design of the cask and its systems that are important to safety.
The bt.ses for the design criteria should be discussed.
5.1 Discussion and Results Discuss the significant shielding design features of the cask and the ade-ouacy of the. shielding.
Table 5-1 (in Section 5.2.2) should be completed.
5.2 Source Specification The gamma and neutron source terms used in the shielding analysis and the spent fuel loadings that would produce these values should be stated.
5.2.1 Gamma Sourw State the quantity of radioactive materi 1 assumed as contents of the cask, and tabulate the gamma decay source strength (MeV/sec and photons /sec) as a function of photon energy.
Describe in detail the method used to determine the gamma source strength and distribution.
5.2.2 Neu, tron ' Source State the quantity of radioactive material assumed as contents of the cask, and tabulate the neutron source strength (neutron /sec) as a function of energy.
Describe in detail the method used to determine the neutron source strength and distribution.
5.3 Model Specification,,n In this section, describe the model that was used in the shielding evaluatien.
- 5. 3.1 Description of the Radial and Axial Shielding Configurations Include sketches (to scale) and dimensions of the radial and axial shield-ing materials.
Dose point locations for the various calculations exterior to I
the package should be shown relative to the source regions in the sketches sup-plied.
Voids or irregularities not taken into account in the model should be i
discussed in detail, showing that the resultant dose rates are conservative.
Differences between the models for nornal conditions and accident conditions should be clearly identified.
5.3.2 Shield Regional Densities, 3
The material densities (g/cm ) and the atomic number densities (atoms /
barn-cm) for constituent nuclides of 611 materials used in the calculational modols for the normal and accident analyses should be given in this section.
The sources of the data should be referenced; provide a copy of the data for uncommon shielding material in Section 5.5.
O 3.61-12
[
m.'..
I I
TABLE 5-1 J
\\
i
SUMMARY
OF MAXIMUM DOSE RATES (mrem /hr) 1 Meter (3 Feet) from Cask Surface Surface of Cask Sides Top Tottom Sides Top Bottom Normal Conditions Gamma el Neutron l
l Total Postulated Accident Conditions Gamma i
Neutron i
9 Total 5.4 Spielding Evaluation Provide a general description of the basic method used to determine the gamma and neutron dose rates at the selected points outside the cask for both normal conditions of storage and accident conditions.
This should include a description of the spatial source distribution and any computer program used, with its referenced documentation.
The basic input parameters should be dis-cunsed in detail.
The basis for selecting the program, attenuation and removal cross sections, and buildup factors should be provided.
Flux-to-dose-rate con-version factors as a function of energy should be tabulated.
Data are to be supported by appropriate references.
5.5 Supplemental Data This section should include supplemental data such as justifications of assumptions or analytical procedures; test results; photographs; computer pro-gram descriptions, documentation, benchmarks, and input / output; and applicoble pages from ferenced documents.
O 3.61-13
6.
CRITICALITY EVALUATION This chapter should identify, describe, discuss, and analyze the criticality safety physics used for design of the cask and its components and systems that are important to safety.
6.1 Discussion and Results J
Discuss the significant criticality design features of the ccsk and the adequacy of the criticality evaluction.
A summary of the criticality evaluation should be included in this section.
6.2 Spent Fuel Loading Provide a summary table showing the maximum spent fuel loading and spent fuel parameters f0r the cask.
6.3 Model Specification This section should contain a description of the mode'i useo in the criti-cality evaluation.
I 6.3.1 Description of Calculational Model
)
Dimensioned sketches (to scale) or the geometric model used in the calcu-lations should be presented.
The sketches should identify the materials used in all regions of the model.
Differences between the actual cask configuration and the mooel should be identified, and the model should be shown to be conser-vative.
Differences between the models for normal conditions of storage and accident conditions should be clearly identified.
6.3.2 Cask Regional Densities 3
The material densities (g/cm ) and the atomic number densities (atoms /
barn-cm) for constituent nuclides of all materials used in the calculational models for the normal and accident analyses are to be given in this section.
Fissionable isotopes are to be considered at their most credible reactivity.
Masses for materials in all regions should be consistent with atomic numbar densities and volumes occupied.
6.4 Criticality Calculation This section should contain. descriptions of the calculational or experi-mental methods used to determine the nuclear reactivity for the maximum fuel loading intended to be stored in the cask.
6.4.]
Calculational.3r Experimental Method A description of the method used to calculate the effective multiplication constant of the cask under normal conditions of storage and accident conditions should be provided.
This should include a description of the computer program and neutron cross sections used with their referencea documentation.
The basis for selecting the program and cross sections should be discussed.
3 61 14
O If an experimental method was used to determine the compliance of the cask l
i (v) with criticality requirements, include a complete description of the method and a discussion demonstrating that the method conservatively takes into account both normal and accident conditions of storage for the cask,
'6.4.2 Fuel Loading or Other Contents Loading Optimization
)
t l
Demonstrate that the maximum reactivity for fuel loading or other contents i
loading has been evaluated for both a single cask and arrays of casks for normal and accident conditions.
Approximations, boundary conditions, calculational convergence criteria, and cross-section adjustments should be itemized and discussed.
6.4.3 Criticality Results Results of the reactivity calculations establishing the most reactive con-figurations for a single cask and arrays of caskt for both normal conditions of storage and accident conditions should be displayed in tabular and graphic form.
Justification should be provided for any interpolations and extrapolations.
A discussion of the validity and conservatism of the analysis should be provided, including the bias established with the benchmark calculations in Section 6.5.
6.5 Critical Benchmark Experiments This section should provide justification for and show the validity of the calculational method and neutron cross-section values used in the analyses.
Revision 2 of Regulatory Guide 3.4, " Nuclear Criticality Safety in Operations p) with Fissionable Materials at Fuels and Materials f acilities," provides sV information on validation of criticality calculations.
6.5.1 Benchmark Experiments and Applicability Provide a general discussion of selected critical benchmark experiments that are to be analyzed using the method and cross sections given in Section 6.4.1.
The applicability of the benchmarks in relation to the cask design and its contents should oe shown.
References giving documentation on these bench-marks should be provided.
6.5.2 Results of the Benchmark Calculations Provide the results of the benchmark calculations.
Establish and provide a discussion of any calculation bias.
6.6 Supplemental Data This section should include information such as juM;fications of assump-tions and analytical procedures; test results; photographs; computer program descriptions, documentation, benchmarks, and input / output; and applicable pages from referenced documents.
O 3.61-15
7.
CONFINEMENT 4
This chapter should identify and discuss cask confinement for normal condi-tions of storage.
The bases for the design criteria should be discussed.
7.1 Confinement Boundary q
Identify the confinement boundary of the cask.
7.1.1 Confinement Vessel A summary of design specifications for the confinement vessel should be provided.
7.1. 2 Confinement Penetrations I
Identify all pene'. rations in the primary confinement boundary.
Provide a summary oi the perfor;oance specifications for all componen'.s that penetrate the confinement boundary.
7.1.3 Seais and Welds Identify all seals and welds that affect cask confinement.
Pruvide a summary of the fabricat'on specifications for these seals and welds, including tests and inspections required for quality assurance.
I 7.1.4 Closure l
Identify the closure devicas used for the confinement vessel.
Specify the initial bolt torque tnat will be required to maintain a positive seal during normal conditions of storage and accident conditions.
7.2 Requirements for Normal Conditions of Storage Summarize the pertinent results of the analyses or tests performed to demonstrate the cask confinement under normal storage conditions.
7.2.1 Release of Radioactive Material Show that there will be no direct release of particulate radioactive mate-rial from the confinement vessel.
Describe the means for detecting radioactiv-ity in the confinement vessel without disrupting the sealing system.
7.2.2 Pressuri2Ation of Confinement Vessel Any vapors or gases the could form in the confinement vessel should be identified.
Shaw that any increase in pressure or explosion within the confinement vessel that is caused by these vapors or gases would not result in a radioactive release that exceeds the limits nf 10 CFR Part 72.
O 3.61-16
i 7.3 Confinement Requirements for Hypothetical Accident Conditions
.7.3.1 Fission Gas Products
' stimate the maximum quantity of fission gas products that cculd be available for release from the confinement vessel under hypothetical accident conditions.
7.3.2 Release of Contents Show that there can be no significant release of radioactive material; exceeding site boundary requirements.
7.4 Supplemental Data This section should include supporting information and analyses.
O O
3.61-17
8.
OPERATING PROCEDURES This chapter shoul ' describe operating procedures recommended for the preparation for and pt, )rmance of the processes of loading, testing, storing, unloading, and maintain. g the function of the cask.
The discussion of these procedures, including appropriate tests, should be presented sequentially in the anticipated order of performance.
At a minimum, thic chapter should demon-strate that the procedures, if properly followed, will ensure that occupational radiation exposures will be maintained as low as is reasonably achievable and that there is reasonable assurance that the health and safety of the public will be protected.
A copy of the recommended procedures and tests should be provided to each user of the cask.
2 8.1 Procedures for Loading the Cask The section should include descriptions of recommended procedures for inspections, tests, and special preparations of the cask for loading.
If appli-cable, present a detailed description of the procedures used to ensure that fluids such as shield water and primary coolants fill their respective cavities, in compliance with the design specifications.
Also provide details of the procedures used to remove residual moisture from cavities designed to be dry.
1 Provide an evaluation of the effectiveness of such precedures.
8.2 Procedures fo.r Unloading the Cal,k This section should include desci iptions of recommended procedures for inspections, tests, and special preparations of the cask for unloading.
As applicable, provide the procedures used to ensure safe removal of fission gases, contaminated coolant, and solid contaminants.
Describe any required cooldown procedure and, if applicable, show that it does not affect reuse of the cask.
8.3 Preparation of the Cask This section should contain a description of recommended procedures for inspections, tests, and special preparations of the cask necessary to ensure that the cask is properly loaded, closed, decontaminated to prevent the spread of contamination, and delivered to a transport vehicle in such a condition that subsequent transport will not impair the effectiveness of the cask to perform its required safety function.
- 8. 4 Supplemental 9ata This section should include supporting documentation, detailed discussions and analyses of procedures, and graphic presentations.
l 9
3.61-18
9.
ACCEPTANCE CRITERIA isND MAINTENANCE PROGRAM This chapter should contain a discussion of the cask acceptance criteria and the cask maintenance program.
The bases for acceptanca criteria should be discussed.
9.1 Acceptance Criteria Discuss the analyses or tests to be performed prior to the first use of the cask.
9.1.1 Visual Inspection The visual inspections to be perfctmed and the intended purpose for each inspection should be discussed.
The acceptance criteria for each of these inspections, as well as the action to be taken if noncompliance is encountered, should be provided.
9.1.2 Structural Describe the analyses or tests to be performed for struttural acceptance.
Present the acceptance criteria and describe the action to be taken when the prescribed criteria are not met.
An estimate of the sensitivity of the tests should be provided and the basis for this estimate should be given.
Leak Tests 9.1.3 Describe the leak tests to be performed.
Leak tests should be performed on the confinement vessel as well as auxiliary equipment that is important to rafety, such as shield tanks.
Describe the acceptance criteria and the action to be taken if the criteria are not met.
Estimate the sensitivity of these leak tests and give the basis for the estimate.
9.1.4 Components Analyses and/or tests for components that are important to safety should be discussed.
If a characteristic (for instance, longevity) cannot be tested, an upper limit should be justified.
Acceptance criteria and actions to be
'taken if the criteria are not met (e.g., replacement) should be presented.
9.1.4.1 Valves, Rupture Discs, and Fluid Transport Devices.
These com-ponents should be analyzed or tested under the most severe service conditions for which acceptable performance is assumed for the cask design. When the tests are presumed to adversely affect the continued performance of a component, the results of tests on components of the same model and type may be substituted.
9.1.4.2 Gaskets.
Gaskets should be tested under conditions simulating the most severe service conditions under which the gaskets are assumed to per-form.
Since these acceptance tests may degrade the performance of either the gasket under test or the cask into which it is assembled or both, the tests are not necessarily performed on gaskets or casks to be put into service.
The 9
simulation system should ensure adequate representation of those conditions that would prevail if the actual system were used in the test.
The manufacturer of the gasket should maintain a quality assurance program adequate to ensure 3.61-19
that acceptance testing of a given gasketing device is equivalent to acceptance testing of all gaskets of that model supplied by that manufacturer.
9.1.4.3 Miscellaneous.
Any component not listed in Sections 9.1.4.1 and 9.1.4.2 whose failure would impair cask effectiveness should be analyzed or tested under the most severe conditions for which it was designed.
Since ac-ceptance tests may degrade the performance of either the component under test or the system into which it is assembled or both, the tests are not necessarily performed on components or systems to be put into service.
The analyses sh2uld ensure adequate representation of those conditions that would prevail if the actual system were in use.
Furthermore, the manufacturer of the component should maintain a quality assurance program adequate to ensure that acceptance testing of a given component device is equivalent to acceptance testing of all devices of that model supplied by that manufacturer.
9.1. 5 Shielding Integrity Discuss the analyses or tests to be performed to ensure adequate shielding for both gamma and neutron sources.
The acceptance criteria as well as the action to be taken if the criteria are not met should be described.
9.1.6 Thermal Acceptance Discuss the analyses or tests to verify that each cask will perform, within some defined variance, in accordance with the results of the thermal analyses or tests for normal conditions of storage.
9.1.6.1 Discussion of Test Setup.
Describe the analysis or test setup.
ihe description should include heat sources, instrumentation, and schematics showing thermocouple and heat source locations as well as the placement of other test equipment.
Estimate test sensitivities based on instrumentation, test item, and environmental variations.
9.1.6.2 Test Procedure.
Discuss the procedures used in all tests and describe the data-recording method.
Report the frequency of data recording during the test.
The criteria used to define the steady-state (thermal equili-brium) condition of the test item should also be discussed.
9.1.6.3 Acceptance Criteria._ Discuss the thermal acceptance criteria and the method employed to compare any acceptance test results with predicted thermal performance.
Discuss the action to be taken if the thermal acceptance criteria are not met.
- 9. 2 Maintenance Program This section should describe the recommended maintenance program that will ensure continued performance of the storage cask.
The program should include recommended testing, inspection, and replacement schedules, as well as criteria for replacement and repair of components and subsystems on an as-needed basis.
O 3.61-20
g I.
/~N 9.2.1. Subsystems Maintenance d
Describe the tests and replacement schedules recommended for storage cask subsystems (e.g., neutron shield tanks) whose inadequate performance could result in the inability of the cask to perform its safety function.
Justify
-J the schedules established, using tests or manufacturers' data.
.l 9.2.2 Valves, Rupture Discs, and Gaskets on Containment Vessel Specify the test and replacement schedule to be used for these components.
Justify the recommended schedules.
DO
'I
(
(
3.61-21
10.
RADIATION PROTECTION This chapter of the TSAR should provide information on methods for radia-tion protection and on estimated radiation exposures to operating personnei during anticipated operation (including maintenance, surveillance, inspections, l
and instrument calibration).
This chapter should also include information on planned procedures and programs and the techniques and practices that should be l
employed by the applicant in meeting the standards of 10 CFR Part 20 for protec-l tion against radiation.
Reference to other chapters for information needed in this chapter shruld be specific.
10.1 Ensuring that Occupational Radiation Exposures Are As Low As l'
Is Reasonably Achievable (ALARA) 10.1.1 Policy Considerations Discuss ALARA policies on occupational radiation exposure with respect to I
cask design, inspections, repair, and maintenance.
10.1.2 Design Considerations Describe considerations of cask design that are directed toward ensuring that occupational radiation exposure is ALARA.
Describe how experience from past designs is used to develop improved design for ensJring that incidents of contamination are minimized.
Describe how the design is directed toward reducing (1) the need for maintenance of equipment, (2) radiation levels, and (3) time spent on maintenance.
10.1.3 Operational Considerations ldentity and describe procedures and methods that could be used to ensure that occupational radiation exposure is ALARA.
10.2 Radiation Protection Design Features Describe cask u sign features used for ensuring a high degree of integrity for the confinement of radioactive materials.
Provide scale drawings of the cask showing the locations of all sources described in Section 5.2.
Include specific activity, physical and chemical characteristics, and expected radioactivity concentrations.
Other information provided should include the potential radiation dose rate for the storage area, maintenance and repair activities, and estimates of radioactive materials that might be discharged during storage.
Reference may be made to specific sections of the TSAR for this information.
10.3 Estimated Onsite Collective Dose Assessment Provide the assumed annual occupancy times, including the anticipated maxi-mum total hours per year for any individual and total person-hours per year for all personnel for each radiation area during normal operation and anticipated operational occurrences.
Also provide the. objectives and criteria for estimated dose rates in tarious areas and an estimate of the annual collective person-rem 3.61-22
doses associated with major functions r,uch as handling and storage operations, O
ancillary activities (e.g., offgas handling), maintent2nce, decontamination, and i
inservice inspection.
Supply the bases models, and assumptions for the above values.
State assumptions made in determining the time-related dose rates.
O 9
O 3.61-23
11.
ACCIDENT ANALYSES The evaluation of cask safety is accomplished in part by analyzing the response of the cask to postulated off-normal and accident events.
Consider (1) minimizing th'e ceases of such events, (2) identification and mitigation of the consequences of accidents, and (3) the ability to cope with each situation if it occurs.
These analyses are aa important aspect of the reviews made by the NRC in evaluating a task design.
In previous chaptars, features important to safety have been identified and discussed.
The purpose of this chapter is to identify and analyze a range of credible off-normal and accident occurrences and their causes and potential consequences.
For each situation, reference should be made to the appropriate chapter and section that describe the design considera* ions to prevent or miti-gate the accident.
The analyses should relate incider.ts to anticipated cask use at nuclear power reactor sites and spent fuel stoaage systems.
ANSI /ANS 57.9-1984, " Design Criteria for an Indepei dent Spent Fuel Storage Installation (Dry Storage Typeh"* defines four categories of events that provide a means of establishing design requirements to satisfy safety criteria.
The first design event is associated with normal operation.
The second and third design events apply to events that are expected to occu during the life of the installation.
The fourth design event is concerned with natural phenomena or low probability events.
Regulatory Guide 3. S, " Design of an Independent Spent Fuel Storage Installation (Dry Storage)," endorses ANSI /ANS-57.9-1984 for use in the design of an ISFSI that uses a dry environment as a mode of storage subject to certain caveates.
11.1 9ff-Normal Operations In this section, design events pertaining to off-normal operation for expected operational occurrences are considered.
They may include equipment malfunctions, radiation leakage, or human error.
In general, the consequences of the events discussed in this section would not have a significant effect beyond the cask storage area.
The following format should be used to present the desired detail.
11.1.1 Event Identify the event, including the portion of the cask involved, the type of failure or m;ilfenction, the component, system or systems involved, and the effects, consequences, and corrective actions.
11.1.1.1 Postolated Cause of the Event.
Describe the sequence of occur-rences that could initiate the event under consideration and the bases upon which credibility or probability of each occurrence in the sequence is determined.
- Copies may be obtained ftom the Amcrican Nuclear Society, 555 N. Kensington Avenue, La Grange Park, IL 60525.
O 3.61-24
~
m-
]; ]\\ -
The following should be provided:
1.
Starting conditions _and assumptions; 2.
A step-by-stap sequence of the course of each accident, identifying all protection systeras required to function at each step; and 3.
. Identification of any personnel actions necessary.
The discussion should show the extent to which protective systems should function, the effect of failure of protective functions, and the credit taken for cask safety features. The performance of backup protection systems during the entire course of the event should be analyzed..The analysis given should permit an independent evaluation of the adequacy of the protection system as
~
related to the event under study.
The results can be used to determine which components, systems, and controls are important to safety and what actions are required under the anticipated operational occurrence.
11.1.1.2 Detection of Event.
Discuss the means or methods, such as visual or audible alarms or routine inspections performed on a stated frequency, to be provided to detect the event.
Provide for each an assessment of response time.
11.1.1.3 Analysis of Effects and Consequences.
Analyze the effects of the event, particularly any radiological consequences.
The analysis should:
1.
Show the methods, assumptions, and conditions used in estimating the course.of events and the consequences, 2.
Identify the time-dependent characteristics and release rate of radioactive materials within the confinement system that could
- k escape to the environment, and 3.
Describe the margin of protection provided by whatever system is cepended on to limit the, extent or magrJ eade of the consequences.
Explain how the cask components and the n materials of construction provide the needed safety margins.
Provide data to support conclu-sions regarding design assumptions.
11.1.1.4 Corrective Actions.
For each event, give the corrective actions necessary to return to a normal situation.
11.1.2 Radiological Impact from_Off-ffurmal Operations Tne capability of the cask to opera.e safely within the range of anticipated operating variations, malfunctions of equipment, and human error snould be shown.
The information may be presented in tabular form with the c'ituations
. analyzed listed in one column and other columns that identify:
1.
Estimated doses (in person-rem),
2.
Method or means available for detectina the situations, 3.
Causes of the situation, 4.
Corrective actions, and 5.
Effects and consequences.
F 3.61-25 j
4 l
i 11.2 Accidents An analysis of potential accidents to the cask (e.g., free fall, overturn, fire) sh0uld be presented.
Include any credible incident that could potentially result in a dose of >25 mrem beyond a postu~1ated controlled area.
If there are no such credible potential accidents, provide the rationale for such a statement.
Such analyses should address situations wherein direct radiation or radioactive materials may be relea,ed in such quanti n as to endanger personnel within the controlled area.
Events that could occur during the cask lifetime, e.g., earth-quakes or other low probability events, simuld be included.
Design events of the third and fourth types defined in ANSI /ANS-57.9-1984 should be included in this section.
The following format should be used to provide the desired detail.
11.2.1 Analysis of Accide:1ts Identify the accident, the portion of the cask involved, and the type of accident.
Discuss each accident sequentially (e.g., 11.2.2, 11.2.3..).
11.2.1.1 Cause of Accident.
For each accident analyzed, describe and list the sequence of events leading to the initiation of the accident.
Identify the type of event such as natural phenomenon, human error, component malfunction, or component failure.
Include an estimate of probability and how this proba-bility estimate was determined.
11.2.1.2 Accident Analysis.
Analyze the effects of each accident, particu-larly any radiological consequences.
Show the methods, assumptions, and con-ditions used in estimating the consequences, the recovery from the consequences, and the steps used to mitigate each accident.
Assess the consequences of the accident to persons and property on the site.
In addition to the assumptions and conditions employed in the course of events and consequences, provide information on the following:
1.
The mathematical or physical models employed in accident analyses.
Include a description of each siinplification introduced to perform the analyses.
Identify the bases for the models used with sp'cific reference to:
a.
The distribution and fractions of the radioactive material inventory assumed to be released from the cask, b.
The concentrations of airborne radioactive materials in the con-finement atmosphere and buildup during the posteccident time intervals analyzed, and The conditions considered in the analyses suc,h'as meteorology, c.
topography, and combinations of adverse con #1tions.
2.
Identificationofarydigitalcomputerprogrr[oranalogsimulation used in the analysis, with principal emphasis on a detailed description of the input data and the extent or range of variables investigated.
This information should include figures showing the analytical models, flow path identification, actual computer listings, and complete listings of input data.
3.61-26
i r
dln
\\
3.
The time-dependent characteristics, activity, and release rate of transmissible radioactive materials that could escape to the environment via l
leakages in the confinement boundaries.
4.
The considerations of uncertainties in calculational methods, equipment performance, instrumentation response characteristics, or other indeterminate effects that should be taken into account in the evaluation of the results.
5.
The conditions and assumptions associated with the cvents analyzed, including any reference to published data or research and development investigations in substantiation of the assumed or calculated conditions.
6.
The extent of system interdependency (confinement systems and other engineered safety features) contributing directly or indirectly to controlling or limiting leakages from the confinement systems.
7.
The results and consequences derived from each analysis and the margin of protection provided by whatever system is depended on to limit the extent or magnitude of the consequences.
11.2.1.3 Accident Dose Calculations.
For each accident analyzed, provide and discuss the results of conservative calculations of putential integrated whole-body and critical-organ doses to an individual from exposure to radiation as a function of distance and time after the accident.
Discuss the results and consequences derived from the analysis and the margin of protection provided by whatever system is depended on (i.e., remains operative) tn limit the extent or magnitude of the consequences.
i l
l l
1
)
i I
i l
'lv i
3.61-27
]
1 l
l 1
t.
12.
0PERATING CONTROLS AND LIMITS 4
Throughout the previous sections of this regulatory guide, the need to identify safety limits, limiting conditions, and surveillance requirements has been indicated.
It is from such information tnat the cask operating controls, limits, and supporting bases should be developed.
These limits should be defined N
and proposed as the operating controls and limits for the car in the TSAR.
12.1 Proposed Operating Controls and Limits identify and justify the selection of those variable conditions and limits based on the design criteria of the cask or determined, as a result of safety assessment and evaluation, to be probable subjects of operating controls and limits for the cask.
The operating controls and limits should be complete; i.e., to the fullest extent possible, numerical values and other pertinent data should be provided, including the support for selection of the technical and operating conditions.
For each control or limit, reference the applicable sec-tions and develop, through analysis and evaluation, the details and bases for the control or limit.
Operating controls and limits should be proposed in the TSAR and accepted by NRC review and evalumtion.
Each cask should have technical specifications, limiting conditions for operation, design features, and surveillance requirements.
Operating controls and limits should be proposed in the TSAR along with an analyses of the bases for the technical specifications and a description of anticipated surveillance requirements.
12.1.1 Content of Operating Controls and Limits Operating controls and limits should include both technical and adminis-trative matters on those features of the cask that are important to safety (e.g., spent fuel loadings, operating variables, or compon2nts).
In addition, operating controls and limits should address the attainment of ALARA levels of releases and exposures.
12.1.2 Bases for Operating Controls and Limits When an operating control and limit has been selected, the basis for its selection and its significance to the safety of the operation should oe described.
This can be done in a summary statement of the technical and operational consid-erations justifying the selection.
The TSAR chould fully develop the details of these bases through analysis and evaluation.
The format for presenting operating controls and limits assumes importance since the collection of con-trols and limits and their written bases form a document that delineates those features and actions important to the safety of operation, the reasons for their importance, and their relationships to each other.
12.2 Development of Operating Controls and Limits Refer to S 72.44, " License Conditions," of 10 CFR Part 72 for guidance on the categories of activities and conditions requiring operating controls and limits.
3.61-28
\\
i
/'
-12.2.1' Functional and Operating Limits, Monitoring Instruments, and Limiting I
Control Settings Controls or limits in this category apply to operating variables that are important to safety and that are observable and measurable (e.g., temperatures j.
within the casi. or evidence of confinement leakage).
Control of such variables F'
is'directly related to the performance and integrity of equipment and confine-ment barriers.
12.2.2 - Limiting Conditions for Operation This category of operating controls and limits covers two general classes, (1) equipment and (2) technical conditions sad characteristics of the cast necessary for continued operation.
12.2.2.1 Eauipment.
Operating controls and limits should establish the lowest acceptable level'of performance for a cask system or component and the minimum number of components or the minimum portion of the system that should be operable or available.
12.2.2.2 Technical Conditions and Characteristics. Technical conditions and characteristics should be stated in terms of allowable quantities, e.g.,
storage temperatures, radioactivity levels in gas samples, area radiation l
levels, and allowable configurations of equipment and spent fuel assemblies during operations.
Specify the allowable quantities associated with limiting conditions, Specific definitions snould be provided for limiting conditions even if they appeared in previcus chapters.
12.2.3 Surveillance Specifications Operating limits and technical specificat, ions should be de feloped and l
presented for anticipated normal, off-normal, and accident operating conditions.
Recommended surveillance procedures, including tests, calibrations, and inspec-l tions, should be provided to cask users to verify availability and performance of systems and components that are important to safety.
These surveillance specifications should be described in this section.
12.2.4 Design Features These operating controls and limits should cover design characteristics of special importance to each of the physical barriers and to maintenance of safety margins in the cask design.
The principal objective of this category is to control changes in the design of essential equipment.
12.2.5 Suggested Format for Operating Controls and Limits 1.
Title:
2.
Specification:
(e.g., maximum radiation level at any surface) l 3.61-29
r 9i 3.
Applicability:
The systems or operations to which the control or limit applies s?ould be clearly defined.
4.
Objective:
The reasons for the control or limit and the specific unsafe conditions it is intended to prevent.
5.
Action:
What is to be done if the control or limit is exceeded; clearly dtfine specific dctions.
6.
Surveillance Requirements: What maintenance and tests are to be performed and when.
7.
Bases:
The TSAR should contain pertinent information and an explicit detailed analysis and assessment supporting the choice of the item and its specific value or characteristics.
The basis for each control or limit should contain a summary of the information in suf ficient depth to indicate the completeness and validity of the supporting information and to provide justifi-cation for the control or limit.
The following mubjects may be appropriate for discussion in the bases section:
a.
Technical Basis.
The technical basis is derived from technical knowledge of the process and its characteristics and should support the choice of the particular variable as well as the value of the variable.
The results of computations, experiments, or judgments should be stated, and analysis and evaluation should be summarized.
b.
Equipment.
If a safety limit is protected by or closely related to certain equipment, such a relationship should be noted, and the means by which the variable is monitored and controlled should be stated.
For controls or limits in categories referenced in Sections 12.2.2 and 12.2.3, the bases are particularly important.
The function of the equipment and how and why the requirement is selected 5hould be noted here.
In addition, the means by which surveillance is accomplished should be noted.
If surveillance is required periodically, the basis for frequency of required action should be given.
c.
Operation.
The margins and the bases that relate to the safety limits and normal operation should be stated.
The roles of operating procedures and of protective systems in guarding against exceeding a limit or condition should be stated.
Include a brief discussion of such factors as expected system responses, operational transients, and malfunctions.
References to related limits should be made.
l f
9 3.61-30
4 13.
QUALITY ASSURANCE Subpart L of Part 72 requires that a quality assurance (QA) program be established, maintained, and executed for structures, systems, and components important to safety.
Cask systems and components that are important to safety should be identified in the TSAR.
The QA program should be applied to design, purchase, fabrication, handling, shipping, storing, cleaning, assembly, inspec-tion, testing, operation, maintenance, repair, and modification of cask systems and components identified as important to safety.
The applicable QA criteria should be executed to an extent that is commensurate with their importance to safety.
A QA program that meets the applicable criteria in Appendix B to 10 CFR Part 50 and that has been accepted by the NRC will be acceptable if it is estab-lished, maintained, and executed with regard to the design, testing, fabri-cation, and repair of the spent fuel storage cask.
Prior to first use, the applicant should notify the Director, Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commission, Washington, DC 20555, of its intent to apply its previously accepted QA program to spent fuel storage casks.
The applicant should identify the program by date of submittal, docket number, and date of NRC acceptance.
A branch technical position entitled " Quality Assurance Programs for Independent Spent Fuel Storage Installations (ISFSI) 10 CFR 72"* has been adopted by the NRC staff for implementing review of quality assurance programs submitted by applicants.
This document could also be applied to a QA program for spent fuel storage casks.
- A copy of this branch technical position is available for inspection and copying for a fee at the NRC Public Document Room, 2120 L Street, NW., Washington, DC, l
under file CE 306-4.
Single copies may be obtained by writing to the Fuel Cycle Safety Branch, Office cf Nuclear Material Safety and Safeguards, U.S.
Nuclear Regulatory Comtnission, Washington, DC 20555.
3.61-31
VALUE/ IMPACT STATEMENT j
A draft value/ impact statement was published with the proposed version of this guide (Task CE 306-4) when the draft guide was published for public a
comment in April 1986.
No changes to the value/ impact statement were necessary, 1
so a separate value/ impact statement for the final guide has not been prepared.
A copy of the draft value/ impact statement is available for inspection and copying for a fee at the Commission's Public Document Room at 2120 L Street NW., Washington, DC, under Task CE 306-4.
1 i
O UNITED STATES
, inst etass u.ait NUCLEAR REGULATORY COMMISSION P05G' * c
WASHINGTON, D.C. 20555 OFFICIAL BUslNEsS PENALTY FoR PRIVATE USE. $300 0
3.61-32
_ _ _ _ _ _ _ _ _ _