ML20247F316
| ML20247F316 | |
| Person / Time | |
|---|---|
| Site: | Brunswick |
| Issue date: | 09/08/1989 |
| From: | Loflin L CAROLINA POWER & LIGHT CO. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| NLS-89-251, NUDOCS 8909180134 | |
| Download: ML20247F316 (1) | |
Text
my s.
' h Carolina Power & Light Company SERIAL:- NLS-89-251-SEP 08 M89 United' States Nuclear Regulatory Commission ATTENTION: Document' Control Desk Washington, DC 20555..
BRUNSWICK STEAM ELECTRIC PLANT,-UNIT NOS. 1 AND 2 DOCKET'NOS. 50-325 & 50-324/ LICENSE NOS. DPR-71 & DPR-62 NITROGEN PNEUMATIC SYSTEM DESIGN
. Gentlemen:
' Carolina' Power & Light Company has reviewed the NRC August 18, 1989 Safety
~
Evaluation (SE) and believes that clarification to results of the staff review-is necessary.
Item (1) on page three (3) states that.the nitrogen pneumatic system is designed to Class 1 seismic requirements. This statement is misleading.in that the entire system is not-Class 1 seismic.' Only those. portions inside the.
-Reactor Building, including containment penetration isolation valves, are Class 11 seismic. This design information was identified in our' letter (Serial:, NLS-88-066) dated March 10, 1988.
Should you have any questions, please contact Mr..D. B. Bates at
. (919) 546-6154.
Yours very truly, L. I Lofl n Manager Nuclear Licensi g Section DBB/crs (468CRS)
' cc:
Mr. S. D. Ebneter Mr. W. H. Ruland Mr. E. G. Tourigny Q0
..8909180134 890908 s
l ' I g) i PDR ADOCK 05000324 P
PDC i
KAd' 411 F tteville Street e P. O Box 1551
- Raleigh. N. C. 27602 m
StMnw
= _ _ _
-