my s.

' h Carolina Power & Light Company SERIAL:- NLS-89-251-SEP 08 M89 United' States Nuclear Regulatory Commission ATTENTION: Document' Control Desk Washington, DC 20555..

BRUNSWICK STEAM ELECTRIC PLANT,-UNIT NOS. 1 AND 2 DOCKET'NOS. 50-325 & 50-324/ LICENSE NOS. DPR-71 & DPR-62 NITROGEN PNEUMATIC SYSTEM DESIGN

. Gentlemen:

' Carolina' Power & Light Company has reviewed the NRC August 18, 1989 Safety

~

Evaluation (SE) and believes that clarification to results of the staff review-is necessary.

Item (1) on page three (3) states that.the nitrogen pneumatic system is designed to Class 1 seismic requirements. This statement is misleading.in that the entire system is not-Class 1 seismic.' Only those. portions inside the.

-Reactor Building, including containment penetration isolation valves, are Class 11 seismic. This design information was identified in our' letter (Serial:, NLS-88-066) dated March 10, 1988.

Should you have any questions, please contact Mr..D. B. Bates at

. (919) 546-6154.

Yours very truly, L. I Lofl n Manager Nuclear Licensi g Section DBB/crs (468CRS)

' cc:

Mr. S. D. Ebneter Mr. W. H. Ruland Mr. E. G. Tourigny Q0

..8909180134 890908 s

l ' I g) i PDR ADOCK 05000324 P

PDC i

KAd' 411 F tteville Street e P. O Box 1551

  • Raleigh. N. C. 27602 m

StMnw