ML20247E176

From kanterella
Jump to navigation Jump to search
Advises That Due to Delay of Final Resolution of USI A-46 Until End of 1989,anticipated Walkdown Associated W/Item Will Be Deferred Until 3 Months After Completion of First Refueling Outage
ML20247E176
Person / Time
Site: Fort Calhoun 
Issue date: 07/20/1989
From: Morris K
OMAHA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
REF-GTECI-A-46, REF-GTECI-SC, TASK-A-46, TASK-OR LIC-89-661, NUDOCS 8907260102
Download: ML20247E176 (2)


Text

_ _ _

1 W

s Omaha Public Power District 1623 Harney Omaha. Nebraska 68102 2247 j

402/536-4000 July 20, 1989 i

LIC-89-661 1

i U. S. Nuclear Regulatory Commission l

Attn: Document Control Desk Mail Station P1-137 l

Washington, DC 20555

Reference:

1.

Docket No. SS-285 2.

Letter from OPPD (K. J. Morris) to NRC (Document Control I

Desk) da*.ed October 6, 1988 (LIC-88-868)

Gentlemen:

i

SUBJECT:

Fort Calhoun Nuclear Plant Revised Walkdown Schedule for Resolution of Unresolved Safety Issue (USI) A-46 I

In Reference 2, Omaha-Public Power District (0 PPD) provided to the NRC a schedule for the plant walkdown associated with the implementation of USI A-46 4

at Fort Calhoun Station. This schedule was contingent upon the completion of generic efforts submitted by the Seismic Qualification Utility Group (SQUG) in its October 9, 1987 letter to the NRC. The SQUG schedule provided for completion of the Generic Implementation Procedure (GIP) by the end of ralendar 1

year 1988, followed by NRC review and issuance of a final SER in the first i

quarter of 1989.

It is now projected that the final SER to be issued by the NRC for USI A-46 implementation will be delayed at least until the end of 1989.

Based on this SER schedule slippage for Fort Calhoun, the anticipated walkdown associated I

with the resolution of USI A-46 must be deferred.

It is OPPD's policy that resources must be allocated for refueling outage projects.several months prior to the start of the outage. The new schedule for Fort Calhoun is to complete the walkdown within 3 months after completion of the first refueling outage that occurs more than 180 days after the NRC has issued the final SER on the l

GIP.

1 As was stated in our previous letter, this walkdown schedule is also contingent upon OPPD's review of the final GIP after approval by the NRC and resolution of I

all outstanding issues.

Based on this review, OPPD will either commit to pursue a generic resolution of USI A-46 or file a plant-specific response.

NO\\

I 8907260102 890720 l

PDR ADOCK 05000285 t \\

i P

PDC 4ssea r mpioumn u oppununnu e...

c. [...

.U. S. Nuclear Regulatory Commission.

LIC-89-661 Page 2 tm

-Should.the generic resolution be pursued, OPPD may elect not to perform certain aspects of the; generic program based upon suitable justification.

If ynu have any questions, please~ contact me.

Sincerely, K.

. Morris'-

Division Manager Nuclear Operations KJM/pjc-c: LeBoeuf, Lamb 'Leiby'& MacRae-R. D. Martin. dRC. Regional-Administrator A. Bournia, NRC Project Manager P.-H. Harrell: NRC Senior Resident Inspector I

1 t

L. -..,

_