g-r e; March 10, 1989 1

?.

lT Docket No. 50-267 Mr. R. O. Williams, Jr.

i Senior. Vice President,' Nuclear Operations Public Service Company of Colorado

~

Post Office Box 840 Denver, Colorado 80201-0840-

Dear Mr. Williams:

SUBJECT:

EQUIPMENT QUALIFICATION CHANGES TO TEMPERATURE PROFILE (TAC NO. 69869)

On February P7,1989, the Commission issued Amendment No._68 to Facility Operating License No. DPR-34 for Fort St. Vrain. This amendnent incorporated a Fixed High Temperature Trip Setpoint for'the Steam Line Rupture Detection

-and Isolation System.

In our review of this item, we considered in detail your submittel dated September 29, 1988, describing the changes to the temperature profile for equipment qualification. Hence, we have decided to discontinue our separate efforts to review that submittal under TAC No. 69869.

That TAC No is now closed.

However, Public Service Company of Colorado should continue its efforts to update the equipment binders for equipment in the scope of the equipment qualification program.

Sincerely,

/s/

Kenneth L. Heitner, Project Manager Project Directorate - IV Division of Reactor Projects.- III, IV, V and Special Projects Office of Nuclear Reactor Regulation cc: See next page DISTRIBUTION Cocket File NRC PDR Local PDR PD4 Reading

-G. Holahan L. Rubenstein J. Calvo P. Noonan gKENeitneryy;:4 OGC-Rockville E. Jordan B. Grimes ACRS.(10)

PO4 Plant File 1

PD4/LA L

PD4/PM PD4/D PNoona KHeitner:sr JCalvo 03/g/

03/9 /89 03//0 /89

?

ll r-I c

n p

~

a

[ ' *.,

<*/

4,

'8 UNITED STATES NUCLEAR REGULATORY COMMISSION l-o L

[;M-

' ti WASHINGTON, D C. 20555 Harch 10, 1989-Docket No. 50-267 Mr.- R. O. Williams, Jr.

Senior Vice President, Nuclear Operations

- Public Service Company of Colorado Post Office Box 840 Denver,- Colorado-80201-0840

Dear Mr. Williams:

SUBJECT:

. EQUIPMENT QUALIFICATION CHANGES TO TEMPERATURE PROFILE

'(TAC NO. 69869)

On February 27, 1989, the Commiss' ion. issued Amendment No. 68 to Facilif.;

Op': rating License No. DPR-34 for Fort St. Vrain. This amendment incorpt.at.d a Fixed High Temperature Trip Setpoint for the Steam Line Rupture Detection and Isclation System.

In our review of this item, we considered in detail your submittal dated September 29, 1988, describing the changes to the temperature profile for equipment qualification. Hence, we have decided to

.discontir.ue our separate efforts to review that submittal under TAC No. 69869.

That-TAC No. is now closed.

However, Public Service _ Company of Colorado should continue its. efforts to update the equipment binders for. equipment in the scope of the equipment qualification program.

Sincerely, Kenneth L. Heitner, Project Manager Project Directorate - IV Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation ec: See next page

m

}k:;

4....-

f Mr. R. 'O. Williams, Jr.

-Public Service Company of Colorado Fort St. Vrain cc:-

Mr. D. W..Warembourg, Manager

. Albert ~J. Hazle, Director LNuclear Engineering Divtsion Radiation Control Division Public Service Company ~

Department of Health'

.of Colorado 4210 East lith Avenue

'P. 0. Box 840 Denver, Colorado 80220

. Denver, Colorado - 80201-0840 Mr. David ~Alberstein, Manager Mr. Charles H. Fuller

~ Fort St. Vrain Services Manager, Nuclear Production GA International Services Corporation

-and Station. Manager LPost Office Box 85608 Public Service Company of Colorado..

San Diego, California 92138 16805 Weld County Road 19-1/2

'Platteville, Colorado 80651 Mr. H..L. Brey, Manager Nuclear Licensing and Resource Mr. P. F. Tomlinson, Manager Management Division.

Quality Assurance Division Public Service Company of Colorado Public Service Company of Colorado P. O. Box 840

-16805 Weld County Road'19-1/2 Denver, Colorado - 80201-0840 Platteville, Colorado 80651 S;nior Resident Inspector Mr. D. D. Hock U.S. Nuclear Regulatory Comission President and Chief-Executive Officer P. 0.. Box 640 Public Service. Company of Colorado

'Platteville, Colorado 80651 Post Office Box 840 Kelley, Standfield & 0'Donnell ATTN: Mr. J. K. Tarpey.

Comitment Control Program Public Service Company Building Coordinator

' Room 900-Public Service Company of, Colorado 550 15th Street _'

2420 W. 26th Ave. Suite 100-D Denver, Colorado 80202 Denver, Colorado 80211 Regional Admittistrator, Region IV U.S. Nuclear Regulatory Comission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas.76011 Chairman, Board of County Commissioners of We's County, Colorado Greeley, Colorado 80631' Regional Representative g

l-Radiation Programs Environmental Protection Agency 1 Denver Place 999.18th Street, Suite 1300 Denver, Colorado 80202-2413

- n