. -. _ _ _. _ _ _
7 9; < ymb Duny. PowEn Goniwsy.
P.O. DOX 33189 i
CHARLOTTE, N.O. 28242
'HALB.TUCKEH (7o7Er"Enm May 15,11989 Document-Control Desk
~
U. S. Nuclear. Regulatory Commission Washington, D.-C.
20555
-Subjects N tawba Nuclear ~ Station, Unit 2 Docket No. 50-414-End of Cycle 2 Steam Generator Inspection.
Gentlemen:
Pursuant to Catawba Nuclear. Station Technical Specifications 4.4.5.5.a and 6.9.2, please-find attached the Catawba Unit 2 end of cycle 2 refueling outage steam generator inspection report.-This inservice inspection of steam generators A,.B, C, and D was performed in April 1989. As a result of this inspection, eight tubes were removed from service by plugging with rolled mechanical' plugs.
Very truly yours',
H. B.' Tucker j"T/3/SGU2E0C2-Attachments xc: Mr. S. D. Ebneter
-Acting Regional Administrator, Region II U. S. Nuclear Regulatory Commission 101 Marietta St., NW, Suite 2900 Atlanta, Georgia 30323 h
.Mr..W. T. Orders NRC Resident Inspector Catawba Nuclear Station
.ek 8905240517 890515 g
\\\\
PDR ADOCK 05000414 Q
1
,.=
j 1
CATAWBA NUCLEAR STATION UNIT 2 END OF CYCLE 2 REFUELING OUTAGE STEAM GENERATOR INSPECTION REPORT a
STEAM TUBES GENERATOR PLUGGED A
2 B
5 C
1 0
0 o
__________.____w