ML20247C262

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-445/89-26 & 50-446/89-26 on 890405-0502 & Notice of Violation
ML20247C262
Person / Time
Site: Comanche Peak  
Issue date: 05/16/1989
From: Warnick R
Office of Nuclear Reactor Regulation
To: William Cahill
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
Shared Package
ML20247C266 List:
References
NUDOCS 8905240382
Download: ML20247C262 (6)


See also: IR 05000445/1989026

Text

7

.

. - .

-

.-

-

-

- - - -

,

,

"

  • c i

o.3 .

".

g

'

MAY I 61989

4

'In Reply Refer'To:

- Dockets:' 50-445/89-26

50-446/89-26

Mr. W. J. Cahill

Executive Vice President

TU. Electric

400iNorth Olive Street, Lock Box 81

Dallas, Texas.

75201

~

Dear Mr. Cahill:

.This refers to the inspection-conducted by Mr. Michael Runyan and

NRC consultants:during the period April 5 through May 2, 1989, of

activities authorized by NRC Construction Permits CPPR-126 and

CPPR-127'for the Comanche Peak Steam Electric Station, Units 1

and 2, Land to.the discussion of our findings with Mr. H. D. Bruner

o

and~other members of your staff at the conclusion of the inspection.

2

LThe enclosed copy of our inspection report identifies areas examined-

during the inspection.

Within these areas, the inspection consisted

of selectiveJexamination of procedures and representative records,

interviews with personnel, and observations by.the inspectors.

During this inspection, it was found that certain of your activities

were in violation of NRC requirements, as specified in the enclosed

,

Notice of Violation.

A written response to these violations is

~ required.

In accordance with 10 CFR 2.790 cf the Commission's regulations, a

copy'of this letter, the enclosures, and your response to this

letter will be placed in the NRC Public Document Room.'

The~ responses directed by this letter and the accompanying Notice

are not subject to the clearance procedures of the Office of

Management and Budget as required by the Paperwork Reduction Act of

1980, PL 96-511.

Y

IP:CPPD:NRR

IP:CPPD:NRR.

AD:IP:CPPD:NRR

MRunyan

HLivermor.

-

RWarnick E'F40

5/14/89

5/tb/89

5//4/89

O

8905240382 890516

'/

PDR

ADOCK 05000445

-

(

g

PDC

'

_ _ . _ _ - _ _ _ _ - _ -

r

1

e.

'

-

e

...

.,

.W. J. Cahill

2

MM' l 61989

.

should you have any questions concerning this inspection, we will be

)

pleased to discuss them with you.

Sincerely,

]

ORTCnnt. SIGNgo 3Y lt F. wAEN10E

R. F. Warnick, Assistant Director

for Inspection Programs

Comanche Peak Project Division

Office of Nuclear Reactor Regulation

Enclosures:

Appendix A - Notice'of Violation

Appendix B - Inspection Report. 50-445/89-26; 50-446/89-26

cc w/crclosures:

See next page

_

_ - _ _

-

_ _ _ _

_

_ _ _ - . _ _ _ .

.-

--

_ _ _ - - _ _ _ _ _ _ _ - . _ _ _ _ . _ _ _ _ _ _ . _ _ _ _ _ _ _ _ _ _ _ , _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ , _ _ _

.

n

.

.

-W

..

50-445/fi- d; 50-446/Bl LG

~

DISTRIBUTION.

De$keEFilesf(50h445/j46);;<

NRC PDR

LPDR-

CPPD-LA

CPPD Reading (HQ)

ADSP- Reading

  • Site Reading File

'

  • R. Warnick

'

  • J. Wiebe-
  • H.-Livermore
  • MIS System,.RIV
  • RSTS Operator, RIV

RPB, RIV

RIV Docket File.

'

  • L.

Shea,. ARM /LFMB:

J. Taylor

C. Grimes

P. McKee

J. Lyons

J. H.. Wilson

M. Malloy'

J. Moore, OGC-WF

M.. Fields

J. Gilliland, RIV

D.:Crutchfield

'E. Jordan

B. Grimes

-B.. Hayes

  • w/766

j

_

_ - - _ _ _ _ - _ . _

_ _ _ _ _ -

E

l

C

L .

.

3 n >ar ,q'o

e

7.-

UNITED STATES

g

NUCLEAR REGULATORY COMMISSION

o

5

E

WASHING TON. D. C. 20555

s

i

%, . . . . . /

MAY I 61989

In Reply Refer To:

Dockets:

50-445/89-26

50-446/89-26

Mr. W. J. Cahill

Executive Vice President

TU Electric

400 North Olive Street, Lock Box 81

Dallas, Texas

75201

Dear Mr. Cahill:

'This refers to the inspection conducted by Mr. Michael Runyan and

NRC consultants during the period April 5 through May 2, 1989, of

activities authorized by NRC Construction Permits CPPR-126 and

CPPR-127 for the Comanche Peak Steam Electric Station, Units 1

and 2, and to the discussion of our findings with Mr. H. D. Bruner

and other members of your staff at the conclusion of the inspection.

The enclosed copy of our inspection report identifies areas examined

during the inspection.

Within these areas, the inspecti;;p consisted

of-selective examination of procedures and representative records,

interviews with personnel, and observations by the inspectors.

-During this inspection, it was found that certain of your activities

were in violation of NRC requirements, as specified in the enclosed

Notice of Violation.

A written response to these violations is

required.

In accordance with 10 CFR 2.790 of the Commission's regulations, a

copy of this letter, the enclosures, and your response to this

letter will be placed in the NRC Public Document Room.

The responses directed by this letter and the accompanying Notice

are not subject to the clearance procedures of the Office of

Management and Budget as required by the Paperwork Reduction Act of

1980, PL 96-511.

4

4

A____.______________

_ _ _ _ . _ _

.

.

.

W. J. Cahill-

2

MAY l 61989

.

.

Should you have.any. questions concerning this' inspection, we will'be

pleased.to discuss them with you.

Sincerely,

TE F u)&

R. F. Warnick,' Assistant Director-

for Inspection Programs-

Comanche Peak Project Division

Office of Nuclear Reactor Regulation

Enclosures:

Appendix'A - Notice of Violation

Appendix'B - Inspection Report 50-445/89-26; 50-446/89-26

cc w/ enclosures:

See next page

)

-____-__-_._:___ _ _ _ _ - _ _ - _ _ _ _

__ . _ - _ _ __

_ _ _ _ _ - _ _ _ - _ _ _ - _ - _ _ - - _ _ . _ - _ _

_ _ _ _ _

_

_

-

_.

._. . _ _ _

. _ _ . ._

. - _ _

4.

-

.

.

"

s

W.

J. Cahill

.

.

ec w/ enclosure:

Roger:D.; Walker

TU Electric

<

Manager, Nuclear Licensing

c/o Bethesda Licensing

TU Electric

3 Metro Center, Suite 610

Skyway Tower.

Bethesda, Maryland

20814

.

400 North Olive Street, L.B.

81

Dallas, TX

75201

E. F. Ottney

P. O. Box 1777

Juanita Ellis

Glen Rose, Texas '76043

President - CASE

1426 South Polk Street

Joseph F.

Fulbright

-Dallas, TX

75224

Fulbright & Jaworski

1301 McKinney Street

Susan M. Theisen

Houston, Texas

77010

Assistant Attorney General

Environmental Protection Division

George A. Parker, Chairman

P.O. Box 12548, Capitol Station

Public Utility Committee

Austin, TX

78711-1548

Senior Citizens Alliance of

Tarrant County, Inc.

GDS Associates, Inc.

6048 Wonder Drive

1850 Parkway Place, Suite 720

Fort Worth, Texas

76133

Marietta, GA

30067-8237

I

Lanny A. Sinkin

Christic Institute

'

1324 N. Capitol Street

Washington, DC

20002

Ms. Billie Pirner Garde, Esq.

Garde Law Office

104 East Wisconsin Avenue

Appleton, WI

54911

Regional Administrator, Region IV

U.S. Nuclear Regulatory Commission

611 Ryan Plaza Drive, Suite 1000

Arlington, Texas

76011

William A. Burchette, Esq.

Counsel for Tex-La Electric

Cooperative of Texas

Heron, Burchette, Ruckert & Rothwell

1025 Thomas Jefferson St., NW

Washington, DC

20007

1:e _ _-_--