ML20247B727

From kanterella
Jump to navigation Jump to search
Forwards Input to Safety Evaluation Rept Being Prepared to Review BWROG Licensing TR NEDO-32291, Sys Analyses for Elimination of Selected Response Time Testing Requirements
ML20247B727
Person / Time
Issue date: 04/12/1994
From: Collins T
NRC (Affiliation Not Assigned)
To: Wermiel J
NRC (Affiliation Not Assigned)
Shared Package
ML20247B617 List:
References
FOIA-98-173 NUDOCS 9805080249
Download: ML20247B727 (16)


Text

tY*%

p 4

t UNITED STATES

[. )!d j

NUCLEAR REGULATORY COMMISSION WASHINGTON. D.C. 20666-0001

'+

April 12, 1994 MEMORANDUM FOR: Jared S. Wermiel, Chief Bi!

Instrumentation & Control Branch Division of Reactor Controls & Human Factors FROM:

Timothy E. Collins, Acting Chief Reactor Systems Branch Division of Systems Safety & Analysis

SUBJECT:

REVIEW 0F BWR OWNERS' GROUP LICENSING TOPICAL REPORT NED0-32291 (TAC NO M83089)

Enclosed is the Reactor Systems Branch input to the Safety Evaluation Report being prepared by your Branch to review the BWR Owners' Group Licensing Topical Report, NEDO-32291, " System Analyses for Elimination of Selected Response Time Testing Requirements".

It is my understanding that you will use this input for developing the overall staff safety evaluation for this license amendment.

Timothy E. Collins, Acting Chief Reactor Systems Branch Division of Systems Safety & Analysis

Enclosure:

As stated cc:

M. Virgilio

Contact:

M. Razzaque, SRXB/DSSA 504-2882 l

E,\\

9905000249 980506 PDR FOIA CHAPMAN 98-173 PDR G/yvJv vven i