Text
- - -
f' UNITED STATES
'T~
g NUCLEAR REGULATORY COMMISSION a!5 ij WASHINGTON, D. C. 20555
{
v k..../
May 9, 1989 7
Docket No. 50-458 Gulf. States Utilities ATTN: Mr. James C. Deddens SeniorVicePresident(RBNG)
P. O. Box 220 St. Francisv111e, Louis,fana 70775
Dear Mr. Deddens:
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION ON THE LICENSEE AltENDHENT APPLICATION UNDER GENERIC LETTER 87-09 FOR RIVER BEND STATION, UNIT NO. 1 (TAC NO. 69579)
The basis for accepting Specification 3.0.4-related amendments under Generic Letter 87-09.is predicated on two assumptions, namely,: 1) that the remedial measures prescribed by the Technical Specification ACTION STATEMENTS for which the exception will be granted provide a sufficient level of protection to permit operational rnode changes and safe long-term operation consistent with the licensing basis described in the Updated Safety Analysis Report for River EendStation,UnitNo.1;and2)thatitwillbetheexceptionwhenplant startup commences with in.portant safety features inoperable, irrespective of the exceptions granted in response to applications under Generic Letter 87-09.
We have reviewed your license amendment application under Generic Letter 87-09, submitted by your letter dated September 30, 1988.
In order for the NPC staff to conclude that the safety basis relative to the above stated assumptions is satisfied, we rcquest that for each proposed Technical Specification exception to be granted under Generic Letter 87-09, you affirm that remedial measures prescribed for the affected ACTION STATEMENTS are consistent with the Updated Safety Analysis Report and its supporting safety analyses.
In addition, we request that you identify and affirm those administrative centrols (e.g.,
maintenance program provisions, plant operating procedures, management directives, onsite safety reviews, etc.) that have been established to limit the use of the Specification 3.0.4 exceptions granted. Your affirmation should adcress training necessary for ensuring that plant operators are made aware of, and are instructed to exercise the controls promulgated in limiting the use of such exceptions.
The flexibility provided by Generic Letter 87-09 with regard to Specification 3.0.4 was intended to be used sparingly by licensees and not as a rule. Some applications have proposed technical specification changes that would rely on Specification 3.0.4 to provide routine relief, e.g., to shorten refueling outages. Such changes are not the thrust of this Generic Letter and they will not be censidered under the umbrella of Generic Letter 87-09. Accordingly, please indicate whether any such propcsed application of Specification 3.0.4 is included in your September 30, 1988 amendment request. Such proposed changes should be withdrawn and resubmitted separately for NRC review.
Ofoi f[}l 8905180419 890509 ADOCK 0500 8
{DR
Mr. James C. Deddens L Please advise, within five days after receipt of this letter, when we may expect to receive your response. Should there be any questions concerning this request, please let me know.
Please note that this request for additional information supersedes the staff's request dated October 27, 1988.
The request in this letter affects fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.
Sincerely,
)
Walter A. Paulson, Project Manager Project Directorate - IV Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation i
cc: See next page 1
l DISTRIBUTION f
Docket File NRC PDR Local PDR I
PD4 Reading G. Holahan L. Rubenstein J. Calvo i
F. Hebdon l
P. Noonan i
W. Paulson OGC-Rockville E. Jordan B. Crimes ACRS (10)
FD4 Plant File PD4/D d PD4/LA /O))
PD '
PHoona U WPdu son:sr JCalvo 05/4[/89 05/d /89 05/$/89
Mr. James C. Deddens Please advise, within five days after receipt of this letter, when we may
. expect to receive your response. Should there be any questions concerning this request, please let me know. Please note that this request for additional information supersedes the staff's request dated October 27, 1988.
The request in this letter affects fewer than ten respondents; therefore, OMB clearance is not required under P.L.96-511.
Sincere 1y, l
- k. &&
l Walter A. Paulson, Project Manager Project Directorate - IV Division of Reactor Projects - III, IV, Y and Special Projects Office of Nuclear Reactor Regulation cc: See next page i
l l
U s:.
Mr.' James C.~ Deddens.
Gulf States Utilities Company River Bend Nuclear Plant cc:-
' Troy B. Conner, Jr., Esq.
Mr. J. E. Booker Conner and Wetterhahn Manager-River Bend' Oversight 1747 Pennsylvania Avenue, NW P. O. Box 2951 Washington, D.C.
20006 Beaumont, TX 77704 Mr. William H. Spell, Administrator Nr..Les England
, Nuclear Energy Division Director'- Nuclear Licensing Gulf States Utilities Company Office of. Environmental Affairs P. O. Box 220 P. O. Box 14690
' St. Francisville, LA 70775 Baton Rouge, Louisiana 70898 Richard M. Troy, Jr., Esq.
Assistant Attorney General in Charge Mr. J. David McNeill, III-State of Louisiana Department of Justice William G. Davis, Esq.
234 Loyola Avenue Department of Justice New Orleans, Louisiana 7011E Attorney General's Office 7434 Perkins Road Resident Inspector Baton Rouge, Louisiana 70808 P. O. Box 1051
-St. Francisv111e, Louisiana 70775 H. Anne P1ettinger 3456 Villa Rose Drive Gretchen R. Rothschild-Reinike Baton Rouge, Louisiana 70806-Louisianians for Safe Energy, Inc.
2108. Broadway. Street New Orleans, Louisiana 70118-5462 President of West Feliciana Police Jury Regional Administrator, Region IV P. O. Box 1921 U.S. Nuclear Regulatory Commission St. Francisville, Louisiana 70775 Office of Executive Director.
for Operations Mr. Frank J. Uddo 611'Ryan Plaza Drive, Suite 1000 Uddo & Porter Arlington, Texas 76011 6305 Elysian Fields Avenue Suite 400 Philip G.- Harris New Orleans, Louisiana 70122 Cajun Electric Power Coop. Inc.
10719 Airline Highway P. O. Box 15540 Baton Rouge, LA 70895 s-
. _ - _ _ _ - - - _ _ - _ _ - _ _ _