ML20246L325

From kanterella
Jump to navigation Jump to search
Ack Receipt of 890613 Submittal of Rev 3c to Emergency Plan, Including Partial Rev to Emergency Action Levels in Table Bya 5-1.Plan Considered Acceptable When Revised Page Bya 5-1.16 Received by Region III
ML20246L325
Person / Time
Site: Byron  
Issue date: 07/07/1989
From: Greger L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Reed C
COMMONWEALTH EDISON CO.
References
NUDOCS 8907180399
Download: ML20246L325 (2)


Text

_

l% Qy s

x3<

w JUL 0 71989 -

y

+

' Docket No;'50-454 Docket No.~50-455' Commonwealth ~ Edison Company

. ATTN:

Mr.. Cordell -Reed Senior Vice President LPost'0ffice Box 767

-Chicago, IL';60690-

Gentlemen
-

This is to acknowledge receipt of your letter of June 13,1989, which transmitted changes to the Byron Nuclear Generating Station. Emergency Plan (GSEP), specifically Revision 3c. This Tevision included a partial. revision to the Byron Emergency' Action Levels (EALs) in Table BYA_5-1.

Emergency Conditions 2,.3, 4, 6 and 9 were affected by this revision.

We have reviewed these' changes which were made due-to an earlier Revision.3b,.

which changed the. emergency 6scription and classification for 'certain water -

levels on.the : river. Descriptions for several other emergency categories in'

.the EAL tables had to be assigned new alphabetical designations because.of

these' prior changes'which resulted in new sequential identities for descriptions of EALs. Our review indicated that we have no further questions about these-change's.

However, in reviewing the EAL tables we noted that for Condition 6c, Page BYA.5-1.16, which describes a fire which cannot be' extinguished in 10 minutes, there was a typographical error that moved the initiating conditions.over one column. As a result, the descriptions for a Site' Area'

. Emergency were moved to the next column which relates to an-Alert; conditions describing an Alert were' transferred to the Unusual Event column; and the Unusual Event-initiating condition was eliminated. Mr. Patterson of my staff discussed this matter with Ms. T. -Lechton, Emergency Planner assigned to the Mazon Training Center on June 23, 1989.

She stated that she would forward a corrected page of these EAL tables or the -same day to all emergency response personnel at the. Byron site, that formal changes to other holders of the Byron 3

.GSEP would be completed in 5 to 7 days after June 23, 1989, and that Mr. Patterson will be informed when all final changes are completed.

Based on the. actions already taken and those in progress at this time, no

.f further correspondence is required. This Revision 3c to the Byron GSEP shall

- be considered acceptable when the revised Page BYA 5-1.16 is received by p

Region III.

p

/

1

/ i V, 3 b i

8907100399 890707 DR ADOCK 050 44 l-f r

e o

L1

_ - - -. - - - - - - - - _ _ _ _ _ _ _ _ _ _ _ _ _. _ _ _ _ _ _ - -__-- _ = _--- _ _. _ _ _ -- _ - _

~

j,, f' b

o s

Commonwealth Edison Company 2 JUL 0 71989 In Accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this letter will be placed in the NRC's Public Document Room.

If you have any questions concerning this letter, please contact Mr. James Patterson of my staff at (312) 790-5536.

Sincerely,

  • 0riginal signed by 17. Snoll'i L. Robert Greger, Chief Reactor Programs Branch cc:

T. J. Maiman, Vice President, PWR Operations T. Kovach, Nuclear Licensing Manager R,. Pleniewicz, Station Manager DCD/DCB (RIDS)

Licensing Fee Management Branch Resident Inspector, RIII Byron Resident Inspector, RIII Braidwood-D. W. Cassel, Jr., Esq.

Richard Hubbard J. W. McCaffrey, Chief, Public Utilities Division Diane Chavez, DAARE/ SAFE L. 01shan, NRR LPM H. S. Taylor, Quality Assurance Division T. W. Travers, EPB, NRR D. Bement, FEMA, RV R. LaFreniere, RIII g

RIII n

RI RII{

RIII lW kS Patte(rson/lms /

Hinds re er S,, Sell g

?

2 /5) 1/.5/Jf

- - - -