ML20246K070

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-336/89-05 on 890211-0323.Compliance W/Tech Spec 6.8.1 & QA Program Will Be Reviewed Further
ML20246K070
Person / Time
Site: Millstone 
Issue date: 05/04/1989
From: Durr J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Mroczka E
NORTHEAST NUCLEAR ENERGY CO.
Shared Package
ML20246K073 List:
References
NUDOCS 8905170236
Download: ML20246K070 (2)


See also: IR 05000336/1989005

Text

- _ - .

..

,.

.w.

MAY 0 4 1989

Docket / License:

50-336/DPR-65

Northeast Nuclear Energy Company

ATTN:

Mr. Edward J. Mroczka

Senior Vice President - Nuclear

Engineering and Operations Group

P.O. Box 270

Hartford, Connecticut

06101-0270

i

Gentlemen:

Subject: Millstone 2 Resident Inspection 50-336/89-05 (2/11/89 - 3/23/89)

The enclosed report refers to the above subject inspection.

The inspectors'

findings have been discussed with Messrs. Scace and Keenan of your staff.

Section 8.1 of the report describes a security event that was identified by

your staff and reported to the NRC in accordance with requirements.

This item

is currently under review by management for appropriate enforcement action.

Our conclusion regarding this matter will be transmitted in separate corres-

!

pondence.

Report Detail 11 and your April 3,1989 letter (813185) address the replacement

i

of in core detectors. We note that you plan, based on the absence of any poten-

tial safety impact, to submit a Technical Specification change to permit simi-

lar activities without senior reactor operator overvies or containment integ-

rity.

Literal adherence to Technical Specifications is required, and the Tech-

nical Specification change should be approved before implementing any changes.

Pending resolution of the change request, this matter is unresolved.

Report Detail 11 notes that Millstone Station ACP-QA-3.02 allows undocumented

minor deviations from procedures. Our preliminary evaluation is that, if such

deviations are not at least documented and dispositioned like other minor dis-

crepancies (e.g., unexpected results), the procedure has been violated. Our

safety review of such conditions at Millstone has identified no safety inade-

quacy.

Nonetheless, undocumented and unreviewed procedure discrepancies have

potential safety consequences, particularly since errors may be compounded over

time.

The associated compliance with TS 6.8.1 and your quality assurance prc'

gram (e.g., ANSI N18.7-1976 Section 5.1.2) will be reviewed further.

Your repair of potentially defective steam generator tube plugs is discussed in

,

Report Detail 10. The response of your engineering and operating staffs to

I

this problem was an instance of good performance.

8905170236 Byg$36

PDR

ADOCK O

pg

G

k

1

fl

l

OFFICIAL RECORD COPY

IR MILL 2 89-05 - 0001.0.0

04/05/89

. _ _ _ _ _ _ _ - _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ - _ _ - _ _ _ _ _ -

,..

, s. . ; ?i

y

s.

' '

Northeast Nuclear Energy Company'

2

MAY o 41989

'Your cooperation with us'is appreciated.

Sincerely,

,

ORIGINAL SIGNED BY

d

Jacque P. Durr, Acting Chief

Projects Branch No. 1

Division of Reactor Projects

Enclosure:'NRC Region I Inspection Report 50-336/89-05

.cc w/ enc 1:

W. D. Romberg, Vice President, Nuclear Operations

R. M. Kacich, Manager, Generation Facilities Licensing

D. O. Nordquist, Director of Quality Services

S. E. Scace, Station Superintendent

Gerald Garfield, Esquire

Public Document Room (PDR)

Local Public'. Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Senior Resident Inspector

State'of Connecticut

bec w/ enc 1:

. Region I Docket Room (with concurrences)

Management Assistant, DRMA (w/o enclosures)

DRP Section Chief

J. Shediosky, SRI, Haddam Neck

D. Jaffe, LPM, NRR

R. Bores, DRSS

R. Keimig. DRFa ' Detail 8.'1)

J. Strosnidet. 9?S(Details 5.4,9.0,10.0)

E. Yachimiak, DRS (Detail 7.0)

C. Anderson, DRS (Details 5.6,13.1)

M. Perkins, DRMA (Detail 11.0)

J. Gutierrez, RI (Detail 11.0)

0

RI:DRP

RI:DRP

RI:DRP

RI:D

MW

0

)

Habighorst/meo

RA9'mond

McCabe

D r

'3D

60

0FFICIAL RECORD COPY

IR MILL 2 89-05 - 0002.0.0

04/05/89

- _ _ _ - _ - _ _ - _ - _ _ - _ - _ - - - _ _ _ - . _

_ - _ . . _ _ _ _ _ _ _ _ - - -