ML20246H146

From kanterella
Jump to navigation Jump to search
Confirms Enforcement Conference on 890321 in Region III Ofc to Discuss Violation Noted in Insp Rept 50-461/89-06,per 890301 Telcon.Violation Re Inadequate Corrective Action for Equipment Qualification Violation Will Be Discussed
ML20246H146
Person / Time
Site: Clinton 
Issue date: 03/10/1989
From: Greenman E
Office of Nuclear Reactor Regulation
To: Gerstner W
ILLINOIS POWER CO.
References
EA-89-059, EA-89-59, NUDOCS 8903200026
Download: ML20246H146 (3)


See also: IR 05000461/1989006

Text

mw~

-

-

.

-

ska "'Ot g[g

U;elTED STATES

NUCLEAR nEGULATORY COMMisslON

]

  • q)

REGION ill

o

ara ' ' '

[

799 ROOSEVELT RO AD

e

y

4

GLEN ELLYN, ILLINOIS 60137

,g

  • ....

. MAR 101989

1

Docket No. 50-461

'EA 89-059

Illinois Power Company

ATTN: Mr. W. C. Gerstner

Executive Vice President

500 South 27th Street

Decatur, IL .62525

Gentlemen:

This confirms our plans as discussed on March 1, 1989 between Mr. M. R'ing of

this office and Mr. S. Perry, Illinois Power Assistant Vice President, to

conduct an Enforcement Conference at 2:00 p.m. (CST) on March 21, 1989 at the

Region III office in Glen Ellyn, Illinois.. The purpose of the Enforcement

Conference is to discuss the apparent violation documented in Inspection

Report No. 50-461/89006(DRS) concerning inadequate corrective action for a..

,

previous equipment qualification (EQ) violation.

1

1

At the Enforcement Conference, you should be prepared to discuss the topics

listed in the enclosure to this letter. We request you provide a handout at

the Enforcement Conference that succinctly describes your position on the

discussion topics.

We will gladly discuss any questions you may have regarding this matter.

Sincerely,

G

r

Division of Reactor Projects

Enclosure: As stated

See Attached Distribution

4

G

'ffW

I(

-_

- - - .. ,

i

1

,

,

d

MAR 10' 1989

-

-

.

.,

Illinois' Power Company'

2

Distribution

cc w/encliiiiire:

D. P. Hall, Vice President

~ J. S. Perry, Assistent

-Vice President ~

R. D. Freeman, Manager,

Nuclear Station

Engineering De

7?!EDCD/DCBItRIOS}%partment-

i

Licensing fee Management. Branch

!

Resident Inspector, RIII

Richard Hubbard

i

J. W. McCaffrey, Chief, Publi'c

!

Utilities Division

!

H. S.-Taylor, Quality Assurance

Division, Sargent & Lundy

Engineers

David Rosenblatt, Governor's

Office of Consumer Services

Sheldon Zabel, Esquire,

i

Schiff, Hardin, & Waite

L. Larson, Project Manager,

General Electric-Company

Chairman of DeWitt County

i

Illinois Department of

j

Nuclear Safety

'

D. Schopfer, Project Manager,

Sargent & Lundy Engineers

]

1

1

1

r

q

i

i

l

_ _ _ _ _ _ _

1

.

- . - - .

.

..

.

.

.

..

..

,

,

ENCLOSURE

Enforcemen,t_,C,onference Discu,s,s, ion Topics

  • 1.

What controls were established to: ensure the effec'ive implementation of

t

,

equipment qualification (EQ) violation corrective action (procedures,

records, training,etc.)?

  • 2.

What type of verification was established to ensure that the corrective

action was completed?

l

3.

What was the root cause.of-the failure to correct all previously.

identified butt-splice and weep hole EQ discrepancies?

  • 4.

What type of controls are in place to ensure that responses /submittals

to the NRC are accurate?

5.

What is the competence level of the EQ Staff in light of the most recent

butt-splice and weep hole inadequacies?

-*The discussion of these topics should address the specifics of the inadequate

i

corrective action to the EQ issues as well as the generic aspects of all

corrective actions.

l

'l

1

'

l

l


_-_______.__--_N