Catawba Nuclear Station, Unit 1 Docket No. 50-413 Special Report Gentlemen:
Pursuant to Technical Specificat.lon 3.3.3.9, please find attached a Specia1 Report concerning the inoperability of Channel No. 6'of the Catawba Unit i Vibration-and Loose Parts Monitor System for more than thirty days. Channel No.~ 6.
.was declared. inoperable on May 21, 1989. This report was schedulled for submittal to the NRC on June 30, 1989. I apologice for the slight' delay.
- Very'truly yours, b.
B. Tucker b
JGT/3/SR9-54 xc:
Mr. S. D. Ebneter Regional Administrator, Region II U. S. Nuclear Regulatory Commission 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr. W. T. Orders NRC Resident Inspector Catawba Nuclear Station 89071401g(($o3Its PDR ADO PDC S
)
e,v,
\\
I CATAWBA NUCLEAR STATION, UNIT 1
)
SPECIAL REPORT I
INOPERABILITY OF CHANNEL No. 6 OF THE STEAM GENERATOR IB
)
l LOOSE PARTS MONITOR SYSTEM 1
i On May 21, 1989 Channel No. 6 of the Catawba Nuclear Station Unit 1 Steam Generator IB Vibration and Loose Parts Monitor System was declared inoperable.
The inoperability of Channel No. 6 was discovered by Operations personnel when i
the Channel emitted c 60 cycle signal after being selected for indication.
{
Previous malfunctions of this system at Catawba Nuclear Station involved loose 4
wiring, loose connections, or faulty accelerometers.
Channel No. 10 of the Unit 1 Steam Generator 1A is operable. Therefore, a redundant channel is available. Work request 506860PS was written to investigate and repair the channel. The repair will be ca:.ied out during a future outage of sufficient duration. This work is to be performed during an outage due to Channel No. 6 being located in the steam generator cavity. This cavity is inaccessible during power operation because of radiological considerations.
The inoperability of Channel No. 6 for more than 30 days is reportable pursuant to Catawba Technical Specification 3.3.3.9.
l l