SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION SUPPORTING AMENDMENT NO.
19 TO FACILITY OPERATING LICENSE N0. NPF-39 PHILADELPHIA ELECTRIC COMPANY 4
LIMERICK GENERATING STATION, UNIT 1 DOCKET NO. 50-352
1.0 INTRODUCTION
I By letter dated January 27, 1989 as supplemented by letter dated March 22, I
1989, Philadelphia Electric Company (the licensee) requested an amendment j
to Facility Operating License No. NPF-39 for the Limerick Generating Station, Unit 1.
The proposed amendment would change the Technical Specifications (TSs) to accommodate the second refueling of the reactor with new, previously irradiated and reconstituted fuel assemblies.
2.0 DISCUSSION Limerick Unit I was shutdown on January 11, 1989 for the second refueling j
outage. Starting in late March 1988, the facility experienced an increasing number of fuel failures which caused gradual power reductions to 1.imit offgas releases. At the time of shutdown, the plant was operating at 41 percent rated power. Prior to the fuel failures, the licensee had planned to replace 224 of the original cycle 1 fuel assemblies for cycle 3 operation, compared to the 268 fuel assemblies that were replaced during the first reload in the summer of 1987. All of these new fuel assemblies contain four rather than two water rods.
In the January 1989 shutdown, there was an intentional delay of several weeks before opening the primary system or turbine to permit decay of radioactive noble gases and sweeping of potential gas pockets out of the i
system through filtered purge systems.
Initial sipping of 296 fuel assemblies from the reactor disclosed 5 leaking fuel assemblies from the initial core load and 13 leakers from the fuel assemblies of the first Unit I reload (reload-1) that had only operated for one fuel cycle. As a result of the initial inspection of the reload-1 fuel assemblies, PECo announced on February 15, 1989, that because of the cladding failures in some reload-1 fuel assemblies, almost all of the 268 reload-1 fuel assemblies also would be replaced with new fuel assemblies purchased for Unit 2.
This is the first incident of Crud Induced Localized Corrosion (CILC) failures in heat-treated cladding. Previously, CILC attack had not occurred until the fuel exceeded at least 15,000 MWD /T exposure. Because Unit I was operated at reduced power to limit off-gas activity, the peak exposures were only about 10,500 MWD /T.
In the reload-1 fuel assemblies that were only exposed for one cycle, CILC proceeded at a much faster rate in some fuel rods than that experienced in other plants with this type of fuel failure.
8905050091 890424*
)
ADOCK 0500 2
gDR
n"-
)
k
(
m Before Unit 1 was-. shut down-in January 1989, the licenser
.d planned to reconstitute 84 fuel assemblies discharged during the ? n sc refueling outage, replacing.non-heat-treated rods with. heat-treated rods. The
-licensee had conservatively established the criteria that only' fuel 4
meeting visual standards 1 or 2 would be reinserted for Cycle 3 restart.
.There were not sufficient donor pins to meet these criteria along with the requisite nuclear. characteristics. The licensee revised its criteria so that non-heat-treated ~ rods could be used, all. rods would be inspected, and heat-treated rods that did not meet visual standcrds 1.or 2 would be replaced. As a result, the licensee only reconstituted 48 of the 2.48-percent-enriched initial core bundles and two reload-1 bundles.
i After a thorough inspection, the licensee cleared 42 of the reload-1 bundles (out of 268) for reinsertion into the core for Cycle 3.
The other initial core and reload-1 bundles that were in Cycle 2 will be discharged, l
The remainder of the core will consist of 152 fuel bundles previously discharged.from the initial core, the 224 fresh fuel-bundles originally scheduled to be inserted, and an additional 296 lower enriched. fresh fuel bundles that are on site and that originally were planned to have been loaded in the Unit 2 initial core.
~
As noted above, the core configuration that will be used for cycle 3 will be.different from that projected when the licensee submitted the proposed TS changes. The core will still consist of new fuel assemblies, previously irradiated fuel assemblies and reconstituted fuel assemblies l
~as discussed.in the staff's proposed no significant hazards consideration determination ~(February 22, 1989,-54 FR 7642).
In that notice, the staff had specifically stated that core configuration was going to be different from that described in the January 27, 1989 application'and that the final core configuration would be dependent on the results of the fuel.
inspections. The staff also-specifically stated that "to account for the above arrangement, the licensee has submitted a bounding. reload analysis for cycle 3."
Once the final core configuration was determined, the
. staff requested the licensee to perform a reevaluation'and reanalysis of the arrangement. By letter dated March 22, 1989 the licensee provided additional. documentation to support their conclusion:
"that the revised reload 2 core configuration is bounded by the. analysis supporting our TS change request and does not constitute an unreviewed safety question."
In the letter of March 22, 1989, the licensee also advised us that one of theproposedMaximumAveragePlanarLinearHeatGenerationRate(MAPLHGR) versus average planar exposure curves that had been submitted as a contingency option would not be needed. The proposed curve was for a reconstituted initial core fuel type to account for the possible replacement of up to four original irradiated gadolinia fuel rods with i
fresh natural uranium fuel rods. The licensee decided not to employ this particular reconstitution option and requested that the optional MAPLHGR curve be delettd from the TS changes requested in the January 27, 1989 application. Deletion of this curve does not affect any of the other proposed TS changes.
1 i
.I
4
. The March 22 submittal does not substantially alter the action as noticed nor affect the staff's initial determination, in that the notice indicated that the precise configuration would be determined based on inspection results and the final configuration comports with the bounding reload analysis in the initial submittal.
3.0 EVALUATION The reload for Limerick Unit I cycle 3 (L103) uses General Electric (GE) manufactured fuel assemblies and GE analyses and methodologies. Enclosed with the application of January 27, 1989 (Ref. 1), which requested proposed changes to the TSs, were reports (References 2 through 4) discussing the reload and analyses performed to support and justify cycle 3 operation and an extended power operating region.
The reload for.L1C3 is a scheduled reload with special consideration given to the requirements resulting from a fuel inspection and reconstitution effort. This effort was necessary because of a potential fuel-failure mechanism resulting from Crud Induced Localized Corrosion (CILC). TS changes are few and primarily related to Maximum Average Planar Linear Heat Generation Rate (MAPLHGR) and Linear Heat Generation Rate (LHGR) limits for the new fuel and Minimum Critical Power Ratio (MCPR) limits for all of the fuel using Cycle 3 core and transient parameters and extended operating regions and conditions. The new fuel is the extended burnup. type which has been used in several recent GE reloads and for which particular attention has been given to special aspects of the TS. The areas of chan reload 1 for Limerick Unit 1 (Ref. 5)ge were the same as the prior The submittal contains a previously approved extension of the original allowed operating region on the reactor power-flow map via an extended loadlinelimitanalysis(ELLLA).
Increasedcore' flow (ICF), final feedwater temperature reduction (FFWTR) and feedwater heaters out of
)
service (FH005) modes of extended operation along with changes to the flow j
biased neutron flux scram and rod block setpoints'necessary for ELLLA and some changed or additional MCPR limits were approved for the previous
)
cycle (Ref. 5). Revised MCPR limits for operation in Cycle 3 are proposed in this amendment request.
)
A revision of the Design Features section of the TS to describe the use of hybrid hafnium control blade assemblies was included in the request.
3.1 Reload Description The LIC3 reload will add 224 new GE 8x8EB fuel assemblies (extended I
burnup type identified in Reference 1) and 296 fresh bundles taken from
~
the Limerick Unit 2 inventory. Those bundles taken from Unit 2 are unirradiated bundles of the same type (BP8x8R) as those previously used in prior reloads of Unit 1.
Thus, a total of 520 (over 2/3) of the 764 fuel i
1 i
I
4 assemblies will be new fuel. Based on visual exams of the initial core and reload 1 fuel, there will be 48 reconstituted 2.48 wt% enriched initial core bundles and two reload 1 reconstituted bundles. The reconstituted bundles have the same nuclear and mechanical characteristics as the original bundles and are considered equivalent to the fresh 2.48 wt% assemblies from the Unit 1 inventory. There are 42 reload 1 bundles that were only irradiated for one cycle that were inspected and cleared for reinsertion into the core for cycle 3.
The remainder of the core will be comprised of 152 initial core fuel bundles that were discharged during the first refueling and that have been inspected and cleared for reinsertion. The loading will be a conventional scatter pattern with low reactivity fuel on the periphery. The assemblies chosen for the periphery are reinserted assemblies from Cycle 1.
The reconstituted assemblies will be distributed symmetrically inside the peripheral region in the revised loading pattern.
The March 22 submittal (Reference.9) was reviewed by staff to the extent l
necessary to confirm that the modeling assumptions used in the reload analyses are valid for the core reconfiguration. The inspection and reconstitution process was necessary because of fuel reliability concerns as a result of a corrosion mechanism which can cause fuel rod cladding degradation (crud-induced localized' corrosion). The objective of the program was to provide a sufficient number of reload fuel assemblies to ensure reliable operation of the Limerick Unit 1 core within its licensing basis. Those considerations relative to the proposed Amendment included nuclear design characteristics, the transient and accident safety analysis results, and the proposed operating thermal limits.
The revised loading pattern uses an increased number of fresh fuel assemblies than normally associated with a typical reload. This creates'an insufficient hot excess reactivity during the initial period after startup which necessitates a power derate to maintain the licensing basis thermal limits (Reference 10).
3.2 Fuel Design The new fuel for Cycle 3 is the GE extended burnup fuel GE8x8EB. The fuel designations are BC 318A and BC 322A. This fuel type has been approved in the Safety Evaluation Report for Amendment 10 to GESTAR II (Refs. 6 and 7) and was used in the prior Cycle 2 reload for Limerick Unit 1.
The specific description of this fuel has been submitted in Amendment 18 to GESTAR II which has been accepted in Reference 8.
In operation the GE8x8EB fuel will be assigned d number of axial lattice regions and appropriate MAPLHGR limits, which have been determined by approved thermal-mechanical and loss of coolant analyses (LOCA) calculations, will be applied to each of these regions. Staff approval for this approach has been granted for the prior Cycle 2 for Limerick 1 (Ref. 5) and remains acceptable.
l 0.____-_______--_-
- 5..
3.3 Nuclear Design The nuclear design for LIC3 has been performed by GE with the approved methodology described in GESTAR II (Ref. 7). The results of these analyses are given in the GE reload report (Ref. 2) in standard GESTAR II format. The results are within the range of those usually encountered for BWR reloads.
In particular, the shutdown margin is 4.8% and 1.2% delta-k at Beginning of Life (BOL) and at the exposure of minimum shutdown margin respectively, thus fully meeting the required 0.38% delta-k. The Standby Liquid Control System also meets shutdown requirements with a shutdown margin of 3.4% delta-k. Since these and other LIC3 nuclear design parameters have been obtained with previously approved methods and fall within expected ranges, the nuclear design is acceptable.
3.4 Thermal-Hydraulic Design
.t' The thermal-hydraulic design for LIC3 has been performed by GE with the approved methodology described in GESTAR II and the results are given in the GE reload report (Ref. 2). The parameters used for the analyses are those approved in Reference 7 for the Limerick class BWR 4.
The GEMINI system of methods (approved in Ref. 8) was used for relevant transient analyses. The revised constants used to calculate the mean scram time, and which are a part of the TS changes for LIC3 (TS 3.2.3), were also approved in Reference 8. These methods and parameters are acceptable.
The Operating Limit MCPR (OLMCPR) values are determined by the limiting transients, which are usually Rod Withdrawal Error (RWE), Feedwater Controller Failure (FWCF) and Load Rejection Without Bypass (LRWBP). The analyses of these events for LIC3 using the standard, approved (Ref. 7)
ODYN Option A and B approach for pressurization transients provide new Cycle 3 TS values of OLMCPR as a function of average scram time, for i
operation in both standard and extended operating regions. For all standard operating conditions FWCF is controlling at both option A and B limits. With the selected rod block setting of 106% the RWE is not limiting. These OLMCPR results are reflected in TS changes. Approved methods (Ref. 7) were used to analyze these events (and others which could belimiting)andtheanalysesandresultsareacceptableandfallwithin expected ranges.
The Limerick 1 TS have standard staff approved provisions for incore neutron detector monitoring of thermal-hydraulic stability according to the recommendations of GE SIL-380. Thus cycle specific stability calculations are not required, either for standard conditions or the extended temperature and power-flow conditions proposed for Cycle 3 operation.
l
l 3.5 Transient and Accident Analyses The transient and accident analysis methodologies used for LIC3 are described and NRC approval indicated in GESTAR II. The GEMINI system of methods (Ref. 8) option was used for transient analyses. The limiting MCPR events for LIC3 are indicated in Section 3.4.
The core wide transient analysis methodologies and results are acceptable and fall within expected ranges.
The RWE was analyzed on a plant and cycle specific basis (as opposed to the statistical approach) and a rod block setpoint of 106% was selected to provide an OLMCPR of 1.25 for all fuel types. The proposed TS change to lower the RBM setpoint from 107% to 106% ensures that the RWE analysis results are bounded by the limiting transient analysis (see Section 3.6).
The mislocated assembly event is not analyzed for reload cores on the basis of HRC approved (see Reference S.2-59 of Ref. 7) studies indicating the small probability of an event exceedin The disorientation event is not analyzed for (symmetric gap) g MCPR Limits.
C lattices. The local transient event analyses are thus acceptable.
The limiting pressurization event, the main steam isolation valve closure with flux scram, analyzed with standard GESTAP II methods gave results for peak steam dome and vessel pressures well under required limits. These are acceptable methoi,logies and results.
LOCA analyses, using approved methodologies (SAFE /REFLOOD) and parameters were performed to provide MAPLHGR values for the new reload fuel assen.blies. These analyses and results are acceptable.
Since Banked Position Withdrawal Sequence rod patterns are used for Limerick 1, a cycle specific control rod drop accident analysis is not required. The basis for this position and NRC approval is presented in Amendment 9 in Reference 7.
3.6 ELLLA, ICF, FFWTR, FHOOS and Inoperable RPT Extensions The staff evaluation for the previous reload approved extensions to standard operating regions in the GESTAR II standard category of " Operating Flexibility or Margin Improvement Options." The selected options are ELLLA (Extended Load Line Limit Analysis), ICF (Increased Core Flow), FFWTR (Final FeedwaterTemperatureReduction)}.FH005(FeedwaterHeaterOutofService),
and RPT (Recirculation Pump Trip These have become commonly selected and approved options for a number of reactors in recent years.
The approved ELLLA changes the Average Power Range Monitor (APRM) rod block and scram lines on the power-flow map, and permits operation up to the new APRM rod block line (0.58W + 50%) up to the intersection with the 100 percent power line occurring at a flow of 87 percent. These are standard changes for ELLLA. For ICF the approved flow increase is to 105
i percent of rated core flow at 100 percent power. The increased flow is allowed throughout the cycle and after normal end-of-cycle (with or without FFWTR) with reactivity coast down. FFWTR involves feedwater temperature reduction up to 60*F (to 360 F at full power) and is proposed only for operation after normal end-of-cycle. Limiting events have been ana'yzed for cycle extension to the exposure attainable using ICF and FFWT' at full power.
For LIC3 the limiting MCPR is bounded by the limits for CF plus FFWTR and may be used throughout the cycle, including cycle extension.
l The GE L1C3 reload report (Ref. 2) presents additional calculations of limiting MCPR transients specifically for L103. The transient analyses demonstrate that the licensing basis results (e.g., 100 percent flow, 100 percent power for pressurization transients) bound the ELLLA region results (e.g., 87 percent flow, 100 percent power). These conclusions apply to all relevant MCPR events such as pressurization, rod withdrawal and flow runout events. Changes to MCPR TS are not required because of ELLLA adoption. Other relevant areas such as over pressure protection, LOCA and containment analysis have also been examined, and the analyses indicate that results are within allowable design limits. Thermal-hydraulic stability will be provided for by appropriate surveillance. The analyses have been done with approved methodologies and the results are similar to previously approved ELLLA extensions. Thus operation within the ELLLA region is acceptable for LIC3.
The standard (Ref. 7) relevant limiting transients and resulting OLMCPR values were calculated for LIC3 for normal operations for appropriate limiting ELLLA conditions, and for the approved ICF, FFWTR and FH00S extension conditions. These calculations included the cycle extension conditions. The results provide OLMCPR values for the TS (MCPR versus scram speed based on ODYN option A and B limits). They use a standard approved methodology and are acceptable.
It was assumed for these transients that the RPT is operable. The
)
limiting MCPR event (FWCF) was also calculated for limiting extension conditions assuming an inoperable RPT. This resulted in increased MCPR limits. Operation with inoperable RPT is proposed for LIC3 throughout the cycle and for various extension conditions using these increased limits.
These calculations follow standard procedures for the inoperable RPT extension and operation within these limits is acceptable for LIC3.
3.7 Technical Specifications The TS char.ges for LIC3 are primarily to provide for:
(a) MAPLHGR limits for the new fuel were determined by approved methods.
1 The additions are Figure 3.2.1-7 and 3.2.1-8 and are acceptable.
(b) Revised MCPR limits for Cycle 3, for extended operation and for the new (GE8x8EB) fuel. The changes are to TS 3.2.3 and Figures 3.2.3-la, Ib, ic, and Id and are acceptable.
l
. 3 I
(c) The Rod Block Monitor maximum trip setting in Table 3.3.6-2 is set at j
106% to correspond to the selection in the RWE analysis. This is i
acceptable.
The acceptability of each of the above changes has been previously discussed in this review. There is also a change to the listed constants in TS 3.2.3 used to calculate the mean scram time. These constants were approvod in the review of Amendment 11 to GESTAR II, (Ref. 9) and are acceptable.
Finali, there are administrative changes to the Design
{
/
Features, to a ref"::nce and to the Bases corresponding to the altered TS.
These changes are also acceptable.
3.8 Considerations Related to Fuel Inspection and Reconstitution Effort "At the request of the staff, the licensee in Reference 9 provided an evaluation of the effects of the inspection and reconstitution effort on the safety analysis results provided in the original Amendment request (fief. 1 ). The staff has reviewed the additional information and confirmed that the core configuration is bounded by the analyses discussed in the prior sections of this SE.
The specific areas reviewed, with the staff conclusions, were:
a.
Fuel design - The 48 rebuilt bundles were reconstituted by replacing up to four rods with donor rods having the same initial U-235 and Gadolinia concentration as the replaced rods.
For a few selected replacement rods, no Gadolinia was used. Lattice calculations for each reconstituted bundic type showed an insignificant change in local peaking and k-infinity from the original analysis.
b.
Neclear design - The cold, xenon-free shutdown margin and standby liquid control margin were seanalyzed for the revised core configuration and it was demonstrated that with the modeling of the reconstituted fuel in the reanalysis, the shutdown margin remained within required limits.
c.
Transient and accident analyses - The analyses of core-wide pressurization transients, non-pressurization events and the loss-of-coolant accident were evaluated for the revised core configuration. These events are affected primarily by the moderator void' coefficient and scram reactivity since the thermal, mechanical, and hydraulic characteristics of the reconstituted assemblies are equivalent to those used in the original analyses. Comparisons of the nuclear parameters for the revised core loading and the reference core loading using the same approved GEMINI methods produced a less negative moderator coefficient for the revised loading pattern compared to the analysis provided in the original Amendment request (Ref.1). A conservative determination of the power shape res< ted in an improved scram response for the revised core configuration.
These results, when considered in the reanalyses, make the reference j
analyses bounding for the core reconfiguration.
e <
Since the above considerations showed the original analyses bound the revised core configuration, no TS changes different from those originally proposed for the Limerick 1 Cycle 3 reload are required.
4.0
SUMMARY
"I We have reviewed the reports submitted for the Cycle 3 operation of Limerick Unit I with extended operating regions. Based on this review, we conclude that appropriate material was submitted and that the fuel design, nuclear design, thermal-hydraulic design, and transient and accident analyses are acceptable. The Technical Specification changes submitted for this reload suitably reflect the necessary. modifications for operation in this cycle. The core reload configuration resulting from fuel inspection and reconstitution efforts was reviewed and it was determined that no additional Technical Specification changes are required since the analyses provided in Reference 1 and supplements are bounding for the revised core configuration.
5.0 ENVIRONMENTAL CONSIDERATION
This amendment involves a change to a requirement with respect to the installation or use of a facility component located within the restricted area as defined in 10 CFR Part 20 and changes to the surveillance l
requirements. The staff has determined that the amendment involves no significant increase in the amounts, and no significant change in the types, of any effluents that may be released offsite and that there is no significant increase in individual or cumulative occupational radiation exposure. The Commission has previously issued a proposed finding that this amendment involves no significant hazards consideration and there has been no public comment on such finding. Accordingly, this amendment meets the eligibility criteria for categorical exclusion set forth in 10CFR51.22(c)(9). Pursuant to 10 CFR 51.22(b), no environmental impact statement nor environmental assessment need be prepared in connection with the issuance of this amendment.
I
6.0 CONCLUSION
The Commission made a proposed determination that the amendment involves no significant hazards consideration which was published in the Federal Register (54 FR 7642) on February 22, 1989 and consulted with the State of Pennsylvania. No public comments were received and the State of l:
Pennsylvania did not have any coments.
The staff has concluded, based on the considerations discussed above, that:
(1) there is reasonable assurance that the health and safety of the p(ublic will not be endangered by operation in the proposed manner, and2) suc regulations and the issuance of this amendment will not be inimical to the common defense and the security nor to the health and safety of the public.
Principal Contributors: Dick Clark, Mike McCoy Dated: April 24, 1989 l
'4 4 References 1.
Letter, and Enclosure 3, from G. A. Hunger, PECo, to Document Control Desk, NRC, dated January 27, 1989. Technical Specification Change Request No. 88-07.
2.
GE Report 23A5926, Rev. O, dated October 1988, " Supplemental Reload Licensing Submittal for Limerick Generating Station, Unit 1, Reload 2, Cycle 3."
3.
NEDE-31401, October 1988, " Basis of MAPLHGR TS for Limerick Unit 1."
4.
NEDE-31401, November 1988, " Basis of MAPLHGR TS for Limerick Unit 1" Errata and Addenda Sheet No. 2.
5.
Amendment No. 7 to Facility Operating License NPF-39 for Limerick l
Generating Station Unit 1, August 14, 1987.
6.
Letter (and attachment) from C. Thomas, NRC, to J. Charnley, GE, dated May 28, 1985, " Acceptance for Referencing of Licensing. Topical Report NEDE-24011-P-A-6, Amendment 10.t' 7.
GESTAR II, NEDE-24011, Revision 8, " General Electric Standard Application for Reactor Fuel."
8.
Letter (and attachment) from A. C. Thadani, NRC, to J. Charnley, GE, dated May 12,1988, " Acceptance for Referencir.g of Amendment 18 to i
Licensing Topical Report NEDE-24011-P-A, ' General Electric Standard l
Application for Reactor Fuel.'"
9.
Letter, with enclosure, from G. Hunger, PEco, to Document Control Desk, NRC, dated March 22, 1989.
Subject:
" Limerick Generating Station Unit 1
- Additional Information in Support of the Reload 2 Technical Specification Change Request.
- 10. Memorandum, M. Restaino, PECo, to R. Clark, NRC, dated March 30, 1989.
Reply to verbal request for additional information on Limerick reload Technical Specification changes.
l