Amends 129 & 159 to Licenses DPR-71 & DPR-62 Respectively, Revising Action Associated W/Tech Spec 3/4.6.4 Re Drywell Suppression Chamber - Vacuum Breaker,To Clarify Alternative Actions to Be Taken If Existing Actions Cannot Be Taken
ML20245H673
Person / Time
Site: Brunswick  
Issue date: 04/24/1989
From: Adensam E
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20245H676 List:
References
NUDOCS 8905030472
Download: ML20245H673 (8)


Text

__

y.

, jy f3 Itto

~{

UNITED STATES -

'o NUCLEAR REGULATORY COMMISSION n

WASHINGTON, D. C,20656 k*****p CAROLINA POWER & LIGHT COMPANY, et al.

DOCKET NO. 50-325 BRUNSWICK STEAM ELECTRIC PLANT, UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.129 License No. DPR 1.

The Nuclear Regulatory Comission (the Commission) has found that:

A.

The application.for amendment filed by Carolina Power & Light Company (thelicensee),datedSeptember 19, 1988, complies with the standards and requirements of the Atomic Energy Act of 1954,-as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B..

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance: (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the-common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical 5 specifications, as indicated in the attachment to this license amendment; and paragraph 2.C.(2) of Facility Operating License No. DPR-71 is hereby amended to read as follows:

8905030472 890424 PDR ADOCK 05000324 P

PDC

l i

e

.2 (2) Technical Specifications-The Technical. Specifications contained in Appendices A and B, as revised through Amendment No.129, are hereby incorporated in the license. Carolina Power & Light company shall operate the facility in accordance with the Technical Specifications.-

3.

This license amendment is effective as of the date of its issuance and shall be' implemented within 60. days of issuance.

'FOR THE NUCLEAR REGULATORY COMMISSION Elinor G. Adensam, Director Project Directorate 11-1 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuan e:

April 24,1989 l

(BSEP12ay4END69548/69549) *SEE PREVIOUS CONCURRENCE n P/1 l

Q: %C1 :

PR* PM:PD21:DRPR*

SPLB:NRR*

OGC*

D D2 :DRPR J

pan X[

ETourigny: dim JCraig SHLewis E

sam 03 03/15/89 03/30 /89 04/10/89 04 89 a

ATTACHMENT TO LICENSE AMENDMENT NO.129 FACILITY OPERATING LICENSE NO. DPR-71 DOCKET NO. 50-325 Replace the following pages of the Appendix A Technical Specifications with the enclosed pages.

The revised areas are indicated by marginal lines.

Remove Pages Insert Pages 3/4 6-18 3/4 6-18 l

L l

jpsuruq[%

UNITED STATES p,

NUCLEAR REGULATORY COMMISSION 5

j WASHINGTON, D. C. 20555 f

CAROLINA POWER & LIGHT COMPANY, et al.

DOCKET NO. 50-324 BRUNSWICK STEAM ELECTRIC PLANT, UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 159 License No. DPR-62 1.

The Nuclear Regulatory Comission (the Comission) has found that:

i A.

The application for amendment filed by Carolina Power & Light Company (the licensee), dated September 19, 1988, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance: (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as ir:dicated in the attachment to this licensc amendment; and paragraph 2.C.(2) of Facility Operating License No. DPR-62 is hereby amended to read as follows:

j

)

FT 1

U.

t j

_2_

(2)JTechnical Specifications The Technical Specifications contained in Appendices A and B,'as-revised through Amendment No.159, are hereby incorporated in the license.

Carolina Power & Light Company shall operate the facility.

in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.and shall be implemented within 60 days of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Elinor G. Adensam, Director Project Directorate 11-1 Division of Reactor Projects I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance:

April 24,1989

  • SEE PREVIOUS CONCURRENCE AmA

/

OFC - lLAt Plf..

7 g.___________:............:____...____.:..

F: )RPR*PM:PD21:DRPR* SPLB*

OGC*
D:

21,BRPR :

_j NAME :,?

'n! W4on- :ETourigny:jw:JCraig

SHLewis
EAde sam

. __ :... L_______:____________:

DATE 2GEELT9-

03/15/89
03/30/89
04/10/89
04Mf89 4
14) f(*1 0F PIGIAL RECORD COPY

CONTAINMENT SYSTEMS 3/4.6.4 VACUUM RELIEF DRYWELL - SUPPRESSION CHAMBER VACUUM BREAKERS LIMITING CONDITION FOR OPERATION 3.6.4.1 All drywell-suppression chamber vacuum breakers shall be OPERABLE and in the closed position with:

a.

The position indicator OPERABLE, and b.

An opening set point of less than or equal to 0.5 psid.

APPLICABILITY: OPERATIONAL CONDITIONS 1, 2, and 3.

ACTION:

a.

With no more than 2 drywell-suppression chamber vacuum breakers inoperable for opening but known to be in the closed position, the provisions of Specification 3.0.4 are not applicable and operation may continue until the next COLD SHUTDOWN provided the surveillance requirements of Specificatica 4.6.4.1.a are performed on the OPERABLE vacuum breakers within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> and at least once per 15 days thereafter, until the inoperable vacuum breakers are restored to OPERABLE status; otherwise, be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

i b.

With one drywell-suppression chamber vacuum breaker in the open position, as indicated by the position indicating system, the provisions of Specificaten 3.0.4 are not applicable and operation may continue provided the surveillance requirements of Specification 4.6.4.1.a are performed on the OPERABLE vacuum breakers, and the surveillance requirements of Specification 4.6.4.1.b are performed within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and at least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> thereafter, until the inoperable vacuum breaker is restored to the closed position; otherwise, be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

c.

With the position indicator of any drywell-suppression chamber vacuum breaker inoperable, the provisions of Specification 3.0.4 are not applicable, and operation may continue provided the surveillance requirements of Specification 4.6.4.1.b are performed within 8 houts and at least onceiper 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> thereafter, until the inoperable position indicator is returned to OPERABLE status; otherwise,'be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

BRUNSWICK - UNIT 1 3/4 6-18 Amendment No. SS,129

ATTACHMENT TO LICENSE AMENDMENT NO.159

~

FACILITY OPERATING LICENSE N0. DPR-62 DOCKET NO. 50-324 Replace the following pages of the Appendix A Technical Specifications with the enclosed pages.

The revised areas are indicated by marginal lines.

Remove Pages Insert Pages 3/4 6-18 3/4 6-18 l

I

e

)

1 1

CONTAINMENT SYSTEMS 3/4.6.4 VACUUM RELIEF DRYWELL - SUPPRESSION CHAMBER VACUUM BREAKERS LIMITING CONDITION FOR OPERATION 3.6.4.1 All drywell-suppression chamber vacuum breakers shall be OPERABLE and in the closed position with:

l a.

The position indicator OPERABLE, and b.

An opening setpoint of less than or equal to 0.5 psid.

l

. APPLICABILITY: OPERATIONAL CONDITIONS 1, 2, and 3.

ACTION:

a.

With no more than 2 drywell-suppression chamber vacuum breakers inoperable for opening but known to be in the closed position, the provisions of Specification 3.0.4 are not applicable and operation may continue until the next COLD SHUTDOWN provided the surveillance requirements of Specification 4.6.4.1.a are performed on-the OPERABLE vacuum breakers within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> and at least once per 15 days thereafter until the inoperable vacuum breakers are restored to d

OPERABLE status; otherwise, be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

b.

With one drywell-suppression chamber vacuum breaker in the open position, as indicated by the position indicating system, the provisions of Specification 3.0.4 are not applicable and operation may continue provided the surveillance requirements of Specification 4.6.4.1.a are performed on the OPERABLE vacuum breakers and the surveillance requirements of Specification 4.6.4.1.b are performed within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and at least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> thereafter until the inoperable vacuum breaker is restored to the closed position; otherwise, be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

c.

With the position indicator of any drywell-suppression chamber vacuum breaker inoperable, the provisions of Specification 3.0.4 are not applicable and operation may continue, provided the surveillance requirements of Specification 4.6.4.1.b are performed within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and at least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> thereafter until the inoperable position indicator is returned to OPERABLE status; otherwise, be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

4 I

BRUNSWICK - UNIT 2 3/4 6-18 Amendment No. Jp3, 159