APR 2 61989 HEMORANDUM FOR: Jack E. Rosenthal, Chief Reactor Operations Analysis Branch I.

Office for Analysis and Evaluation of Operational Data THRU:

Peter S. Lam, Chief Reactor Systems Section W and B&W Reactor Operations Analyiis Branch Office for Analysis and Evaluation of Operational Data FROM:

L. Mark Padovan, Reactor Systems Engineer Reactor Systems Section W and B&W Reactor Operations Analyiis Branch Office for Analysis and Evaluation of Operational Data

SUBJECT:

COMPONENT DEGRADATION DUE TO INDISCRIMINATE PAINTING Enclosed is a Technical Review Report on the above subject.

This study was initiated as a result of occurrences at Catawba, wherein drains on the housings of motor actuators were inadvertently painted, causing invalidation of environ-mental qualification of the motor operators and inoperability of safety related valves.

Based on available data, the study concludes no generic considerations are associated with component degradation from indiscriminate painting. Accordingly, no additional AEOD actions are warranted at this time.

Original signed by L. Mark Prdovan, Reactor Systems Engineer 8905030036 890426 Reactor Systems Section W and B&W PDR ADOCK 05000413 Reactor Operations Analysis Branch S

PNV Office for Analysis and Evaluation l

of Operational Data

Enclosure:

As stated i

Distribution FDR EJordan

' Central File BBrady ROAB'R/F WLanning MPadovan MTaylor Plam VBenaroya KBlack O

{

MWilliams

\\

\\

TNovak k h CHeltemes AB:DSP:AEOD I

ROAB:DSP(A [E0D 0AB:DSP:AE0D uk JRo enthal I

Plam MPadovan:mp/as 4/A/89 4/26/89 4// 89 l

l