ll 3.4 STEAM AND POWER. CONVERSION' SYSTEM..
1 Applicability i
Applies to the turbine cycle components for removal of reactor decay heat.
1 Objective l
To specify minimum conditions of the turbine cycle equipment 'necessary to 1
assure'the capability to remove decay heat from the reactor core.
Specifications 3.4.1l J he reactor.shall not be heated above 280 F unless'the following conditions are met:
1.
Capability to remove decay heat by use of two steam generators.
I
- 2.
Fourteen of the steam system safety. valves are operable.
3.
A minimum of.11.1 feet (107,000 gallons) of water is available in Tank T418.
- 4.
Both EFW pumps and their flow paths are operable.
5.
Both main steam block valves and both main feedwater isolation valves are operable.
3.4.2 Initiate functions of the EFIC system-which are bypassed at' cold shutdown conditions shall have the following minimum operability.
conditions:
a.
" low steam generator pressure" initiate shall be operable when the main steam pressure exceeds 750 psig.
J b.
" loss of 4 RC pumps" initiate shall be operable when neutron flux exceeds 10% power.
c.
" main feedwater pumps tripped" initiate shall be operable when neutron flux exceeds 10% power.
- Except that during hydrotests, with the reactor subcritical,. fourteen of j
the steam system. safety valves ~may be gagged and two (one on each header),
l inay be reset for _the duration of the test, to allow the required pressure for.the test to'be attained.
..j
- Except that a test with available steam. pressure of the steam' driven EFW' l
pump shall demonstrate its functionality'until completion of. surveillance,
i testing at hot shutdown' conditions as required by Surveillance' Requirement'4.8.1.
1j 1
l 4
j' Amendment No. 50, 90, 91, 101 40 i
8906260133 890613 U