,_

)

OPERAllHS DATA REPORT i

I DDCKET ND 50-413 TATEJune 15. 1989 OPERATING STATUS COMPLETED PY P.A. Willi ns TELEPHONE 704-373-5987___

j

1. Ur:it Name: Cata b 1
2. Reporting Feriod: May 1, 1989-May 31, 1989
3. Licensed Thermal Power (MWti:

3411

4. Naceplate Rating (Bress MWe):

130$s Notes

  • Nameplate Rating

[

5. Design Electrical Rating (Net MWe):

1145 (Bross MWe) calculated as l

6. h irca Dependable Capacity (Gress MWe):

1192 1450.000 MVA x,90 power

7. Waximus Deperfable Capacity (Net MWe):

1129 fatter per Fage iii,

8. If Changes Occur in Capacity Ratings (Itets Number 3 Thrtegh 7) Since Last NUREG-0020.

Repert. Gne Reasons:

9. Peter Level To Which Restritted, If Any (Net MWe):

I

10. Feason Fcr Restrictions, If any:

This Month Yr.-to-Date Cutulative i

11. Hours Ir, Reporting Feriod 744.0 3623.0 34392.0 l
12. Nuecer Of Hours Reactor Was Critica!

744.0 2682.4 248!6.2

13. Eeactor Reserve Shutdown Hours

--0--

--0--

--0--

14. Hours Generator On-Line 744.0 2531.6 24135.7
15. Unit Feserve Ebutdown Hours

--0--

--0--

--0--

16. Stoss Thereal Energy Generated (MWH) 24683B3 2167483 77i25869 l
17. Gress Electrical Energy Generated (GH) 886930 2B59661 27053312
18. Net Electrical Energy Generated (MWH)

E40377 2671745 E5307267

19. Unit Service Facter 100.0 69.9 70.2

)

20. Unit Availability fecter 100.0 69.9 70.2 j
21. Unit Ca;acity Factor fusing MDC het) 100.1 65.3 64.6 q
22. Lnit Capacity Facter (Using DER Net) 98.7 64.4 64.3 i
23. Unit Forced Datage Rote 0.0 7.8 14.B

)

24. Shtth Nn Schedcled Over Next 6 Menths (Type, Date, and Duratier cf Each):

l Nnno I

25, if Shut Dcin At End Of Fepcrt Feriod. Esticated Eate of Startup:

l

26. Ur:its in Test Status (Frict to Comtettial Operation):

\\

Ferecast Acheved 1

INITIAL CRITICAL 1iY l

INITIAL ELECTRICITY l

COMMERCIAL DFERATIDN l

8906220179 PDR ADOCK

~000 13

~R PNU

~~

n,c. '

.q.,

p h;

. OPERATINS DATA REPORi;'

L DOCKET ND 50-413 UNIT Catawba 1 L

DATE Jne 15. 1989 COMPLETED BY - R.A. Williams TELEPHONE 704-373-5987 5

K

MONTH May.'1989'

'QAl'

AVERASE DAILY M WER LEVEL PAY AVERABE DAILY PDWER LEVEL-

'im;-NetP (MWe-Net) 1:

.1

'~1117 17 1138

'2

'1123 10 1137 l3 1119 19 1135-

'4 1131 20 113?

5

-1122 21 1130

.6 1126 22 11P9 7

1133 23 1130 8

1139 24 11 %

-9 1135 25 1129

-10 1138 26 1123 11 1139 27 1120 12 -

1137 29 1120

-13 1138 29 110P l:14 1139 30 1123 15 1137 31 1121

16:

1140 L

l 1i l

I I

jl i

J e

.s'a se y

n e

otn c

iae r

2

.tDc u

6 c

i -

o 7

ufL)

S 5

ro R)

~

D t

rE1 e

A 3

,snoL6 m

1 9

E 7

.noF( 1 a

8 M 3 E

Ii 1 0 S

3 A /

V E

tst-1 B 5

. )

I C

atrG 4 W 1 J 4 T

N reoE

- A /

0 C

E GaepR I

0 T 6

. 7 E

R ph e U 5 A 0 J ROR teSRN t

(

C RTU ir i.

(

O C

b P yt b

.EEYE CNE i

rne i

OMTBN OR hrtel h

NAA O

DI xonvi x

NDDH NTT EfEEF E

)

)

T EP ACN 4

5 ET TE AE

(

(

KI EL E

V CN LE S

E OU PT U

R D

.M A

P O

C m)

C an ri mca aSl r

p ccx SiEt(

S lla N

aamr O

T duuoe I'

N onnth T

)

E haaut C

9 5

NE tMMAO U

8

-(

OD e-D 9

PO M1234

)

E 1

MC 3

R' O

(

y C

R a

n E

M E

S o

W SMD N

i

)

O 4

YEO O

t

('

STC I

a P

T n

D C

i N

U m

A E

D a

S T

E x

S NTR R

E N

ENO W

H CEPO T

e

)

O T

IVEN N

n s

D N

LER A

i n

T O

C a

e

)

U M

I l

c n

H TN F

p ni i

S T

TD UWX I

x oL a

)

R 3EOFHO/

N E

i l

T O

MHOSDR s

c x

t t&

p G

(

(

I P

ee i g E

N E

S

)

U R

2 rt rn

(

REASON R

u ti

(

)

O l

lr snern io eivoi N

S a

Raira O

N Fe rtrl IS W

c yTaEp TR O

tngr r

x AU D

nanortrE RO T

enitoso(

UH U

melatit D

H ptelanar S

ninuurire o uif g e m eh O

s q a e e pd pt

)

1 TYPE N

aEMRROAOO

(

e-RABCDEFGH

)

2

(

E d

T e

A l

D du ed ce rh oc FS NO FS

)

1 g

(

[L lI l'

DOCKET NO:

50-413 UNIT:

Catawba 1 DATE:

06/15/89 NARRATIVE

SUMMARY

Month: May, 1989 Catawba Unit 1 operated at or near 100% full power for the entire month of May, without any significant reductions.

)

Prepared by:

J. J. Mead

' Telephone: 704-373-5762 l

{

i

li,

l'<

^

I L MONTHLY REFUELING.INFORMATION' REQUEST s

c-1.

Facility name:: Catawba, Unit I "r

2.

Scheduled next refueling shutdown: January 1990

'3.. Scheduled restart following refueling: March 1990

'E 4.

Will refueling or resumption of operation thereafter require a technical specification change or other license amendment?f No If'yes, what will these be?

LIf no, has reload design and core configuration been. reviewed by Safety Review' Committee regarding unreviewed safety questions? N/A 5.

Scheduled date(s) for. submitting proposed licensing action and supporting information: N/A.

6.

Important, licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or: new' operating procedures).

7.

Number'of fuel assemblies (a) in the core: 193 (b) in the spent fuel pool: 196 8.

Present licensed fuel pool capacity: 1418 Size of requested or planned increase:

9.. Projected' date of last refueling which can be accommodated by present

-licensed capacity: September, 2011 l

DUKE POWER COMPANY DATE:

June 15, 1989 Name of.

Contact:

J. A. Reavis Phone: 704-373-7567 c ______ _ _ _ _ _ _ _ _. - _ -. -

i

'I

.'i

/

DPERATING DATA REPORT.

. DOCKET NO 50-414 DATEJune 15. 1909 OPEPATIN5 STATUS-COMPLETED BY R.A. Williams TELEPHONE 704-373-5987

1. Unit Naset Catawba 2 -
2. Reporting Period: May 1,1989-May 31,1989
3. Licensed Thereal Power (MWt):

3411

4. Nasteplate Rating (Bross MWe):

1305+~

~ Notes' + Nameplate Rating

' 5.DesignElectricalRating(NetMWe):-

!!!45 (Gross NWel calculated as

6. Mexieue Dependable Capacity (6ross NWe):

1192 1450.000 MVA x.90 power

7. Gaxiste Dependable Capacity (Net MWn):

1129 factor per Page ill,

.B. If Changes Dccur in Capacity Ratings ilters Number 3 Through 7) Since Last NUREB-0020.-

Report.'EiveReasons:

. 9, Power Level Te Which Restricted, If Any (Net MWe):

110.F.eason.ForRestrictions,Ifany::

p This M: nth. Yr.-to-Date Cumulative

11. Hours In Reporting Period 744.0 3623.0-24408.0-

' 12. Number Of Hours Reactor Was Critical 0.0 1525.9, 16628.3-

'13. Reactor Reserve Shutdown Hours

--0--

--0-- -

14. Heurs Benerator On-Line 0.0 1497.1 16147.7
15. Unit Peserve Shutdown Hours

--0--

--0-- -

16. Bross Thersal Energy Generated (MWH) 0' 4613376-49177601
17. Gross Electrical Energy Generated (MWH) 0 1652091 17340212
10. Net Electrical Energy Generated (MWH)

-13853 1533179' 16170011

~19; Unit Service Factor 0.0 41.3 66.2 20.UnitAvailabilityFactor 0.0 41.3 66.2

21. Unit Capacity Factor (Using MDC Net) 0.0.

37.5 58.3

22. Unit Cesa:ity Factor (Using DER Net) 0.0 37.0 57.9
23. Unit Forced Dutage Rate 0.0 9.0 21.4
24. Shutdown Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

None-

-25. If Shut Dcwn At End Of Report Period. Estinated Date of Startup: June 9, 1989

~ 26. Units In Test Status (Prior to Coesercial Operation):

Forecast Achieved

-INITIAL CRITICALITY INITIAL ELECTRICITY COMERCIAL OPERATDN

= - -. _ _ _ _ _ _ _ - _ - - _ _ _

g.

4:

e I'

e-0 w

...t :.

i

. l,.

OPERATINB DATA REPORT-j

.c,.-

. DOCKET ND 50-414-UNIT :

Catawba 2-DATE June 15, 1989 l

COMPLETED BY R. A. Willians l

' TELEPHONE-704-373-5987-'

i

\\

l

.I MONTH ~

May,1989

pg AVERABE DAILY POWER LEVEL DAY AVERABE DAILY POWER LEVEL RWe-Net)

(MWe-Net)

.1 t

o g7

'O' l

r.2 i 0

10. -

0

3 O

19 0

4' 0

20 0

.5 0-21 0

.<:.I 6'

0~

22 0

i

)

- 7..

~0 23 0

0 0-24

-0 0-9 0

25 0

10 0

26 0

I

' 11 -

0 27 0

12:

0 28 0

i 13 0

29 0

14 0

30 0

15 0

31 0

1-l l'

-16 0

i L

1.

i i

1 (L

L-i L

1.

1

________________________________________________________________________j L-

l l

e s

e nas e

otn c

iae

.r 2

tDc u

6 c

i o

ufL)R)

S 7

ro 5

G E

D N

G t

rE1 e

2 A 3 I

A snoL6 m

9 E

7 L

T noF(1 a

A 8 M 3 E

E U

Ii

. 0 S

4 B /

V E

U O

tst -

1 W 5

)

I C

F

- atrG 4 A 1 J

4 T

N E

G reoE

- T /

0 C

E R

N GaepR I

0 A 6

. 7 E

R I

pheU ROR L

L teSRN t

5 C 0 J

(

RTU A

E ir

(

i O

C M

U b P yt b

.EEYE

.CNE R

F i

rne i

OMTBN OR O

E hrtel

.h NAA O

DI N

R xonvi x

NDDH NTT EfEEF E

)

)

c T

EP ACN 2

2 4

5 ET TE AE

(

(

KI EL E

V E

E CN

.LE S

E L

L OU PT U

R C

C D

M

.A

.P Y

Y O

C C

C m)

C N

an F

FU ri O

OR mca R

aSl D

DE r

p N

NV ccx E

EO SiEt(

S lla aamr N

O T

duuoe I

N X

X onnth E

X X

haaut T

)

C 9

5 NE L

L

. tMMAO OD E

E e-U 8

(

M1234 D

9 PO U

U

)

E 1

MC F

F 3

R O

(

y C

R a

n E

M E

o SMD C

C i

W

)

O 4

YEO R

R t

STC a

P

(

n D

i N

m A

E a

S T~

x S

NTR E

N ENO e

W H

CEPO

)

O T

IVEN n

s D

N LER i

n T

O a

e

)

U M

l c

n H

TN p

ni i

TD UWX x

oL a

S T

)

R 3EOFHO/

1 1

E i

l t

t&

p T

O MHOSDR

(

(

I P

s c

x ee i g E

N E

)

U R

2 C

C rt rn

(

REASON u

ti

)

(

lr snern io eivoi N

0 0

a Ra1ra O

0 0

Fe rtrl c

yT a E p IS TR 2

2 tngr r

x AU 7

7 nanortrE RO 3

3 enitoso(

UH melatit ptel anar D

ninuurire ouif gemeh s q a e e pd pt

)

1 TYPE S

S aEMRROAOO e-(

RABCDEFGH

)

2 1

6

(

1 E

5 5

d T

e A

l D

9 9

du 8

8 ed ce rh oc FS NO 6

7 FS

)

1 lll{

lll!

[

7------__._--_

lo l

DOCKET NO:

50-414 UNIT:

Catawba 2 DATE:

06/15/89 NARRATIVE

SUMMARY

Month: May, 1989

' Catawba Unit 2 was out of service for the entire month of May for its End of Cycle 2 Refueling Outage.

[

Prepared by:

J. J. Mead Telephone: 704-373-5762 i

i 1

f

.-._----a--.-_.

4 t

MONTHLY REFUELING INFORMATION REQUEST 1.

Facility name: Catawba, Unit 2 2.

Scheduled'next refueling shutdown:

January 1990 3.

Scheduled restart following refueling: March 1990 4.

Will refueling or resumption of operation thereafter require.a technical specification change or.other license amendment? No 1

If yes, what will these be?

If no, has. reload design and core configuration been' reviewed by Safety h-Review Committee'regarding unreviewed safety questions? N/A 5.

Scheduled date(s) for submitting proposed licensing action and supporting information: N/A 6.

Important' licensing considerations.(new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or new operating procedures).

7.

Number of fue1' assemblies (a) in the core:

193 (b) in'the spent fuel pool:

136 8.

Present licensed fuel pool capacity:

1418 Size of requested or planned increase:

9.

Projected date of last refueling which can be accommodated by present licensed capacity:

January, 2013 L

l I

DUKE POWER COMPANY DATE:

June 15, 1989 Name of

Contact:

J. A. Reavis Phone:

704-373-7567 l-c