7 r ~,

7s.

J i Commonwealth Edison v

[

/ 72 West Adams Street, Chicago, lainois e_

/

\\ '~'/ Chicago, Illinois 60690 - 0767ddF6ss IIeTy~toWsfDffIce N e

i April 26, 1989 w

Commonwealth Edison 2

.~ _.. _."

S/fEGUARDSJMFORMAT10!I Mr. A. Bert Davis gg Regional Administrator U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137

Subject:

Zion Nuclear Power Station Units.1 and 2 License Nos. DPR-39 and DPR-48 Response to Notice of Violation HRC Docket Nos. 50-295 and 50-304 References March 27, 1989 letter from C.E. Norelius to J.J.

O'Connor transmitting Inspection Report Nos.

50-295/89003 and 50-304/89003

Dear Mr. Davis:

This letter is in response to an inspection performed by Ms. G.M.

Christoffer of your staff on January 10, 12 Eld 24, 1989, at Zion Station.

The details of the event were then further discussed at an Enforcement Conference that was he.1d on February 16, 1989. The information was obtained during the inspection and the Enforcement Conference was used to complie

' Inspection Report Nos. 50-295/89003 and 50-304/89003.

It was concluded that certain activities appeared to be in violation of NRC requirements. The response to the violation is provided in the Attachment in this letter.

The Attachment to this letter contains Safeguards Information as defined in 10 CFR 73.21.

Accordingly, this information must be protected f rom public disclosure.

Please direct any questions regarding this matter to this office.

Very truly yours,

/r T. J.

ovach Nuclear Licensing Manager 1m 1 0 Attachments SECURITY MARKING DOES 30T APPLY 42TTER IS SEPARATE FROM THE ENCL cc:

Resident Inspector - Zion 8906200325 890426 APR 2 8 id PDR ADOCK 05000295 0098T

_ - - _ - _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _