Responds to NRC Bulletin 88-008 & Suppl 1, Thermal Stresses in Piping Connected to Rcs. Based on Results of Ultrasonic Exams of Unit 2,util Determined That No Reportable Indications Noted
ML20244C622
Person / Time
Site: Farley  
Issue date: 06/08/1989
From: Hairston W
ALABAMA POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
IEB-88-008, IEB-88-8, NUDOCS 8906150048
Download: ML20244C622 (2)


Text

__- __-_

lp O

" Alabama Power Company 40' Inverness Center Parkway.

Post Office BJ 1295 Birmingham, Alabama 35201 7-Telephone 205 868-5581 W. G. Hairston, til Senior %ce President Nuclear Operations, gg g

t% sow %m elwtrc sntem 10CFR50.54(d)

June 8, 1989 Docket Nos. 50-348 50-364 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Vashington, DC 20555 Gentlemen:

J. M. Farley Nuclear Plant - Units 1 & 2 Thermal Stresses in Piping Connected to Reactor Coolant Systems - NRC Bulletin No. 88-08 NRC Bulletin No. 88-08 and Supplement 1, issued June 22, 1988 and June 24, 1988 outlined actions for. licensees regarding thermal stresses in piping connected to reactor coolant systems. By letter dated July 28, 1988, Alabama Power Company responded to Bulletin No. 88-08 and Supplement 1 stating that Action 1 was complete and that Action 2 and 3 items would be completed by the end of the next refueling outage for each unit.

Subsequent to Alabama Power Company's response, the NRC issued Bulletin No.

86-08 Supplements 2-and 3, dated August 4, 1988 and April 11, 1989. These supplements discussed enhanced ultrasonic testing methods and thermal stresses resulting from valve seat leakage through packing glands.

Alabama Power Company has since re-evaluated the scope of piping considered to be susceptible to thermal stratification or temperature oscillation.

In addition to the safety-injection lines previously described in the July 28, 1988 letter, the following lines are now considered susceptible:

normal and alternate charging, pressurizer auxiliary spray, and Reactor i

Coolant System (RCS) to Residual Heat Removal (RHR) suction.

In response to Action 2 of NRC Bulletin No. 88-08, Alabama Power Company performed ultrasonic. examinations on the Unit 2 hot and cold leg safety injection lines, normal and alternate charging lines, pressurizer auxiliary spray line, and RCS to RHR suction lines. Based on the results of these examinations, it was determined that there vere no reportable indications.

These examinations were performed using the enhanced ultrasonic examination techniques and procedures described in Supplement 2.

8906150048 890608 PDR ADOCK 05000348 O

PDC u _

i.
'

'A U. S. Nuclear Regulatory Commission Page 2 In response to Action 3 of NRC Bulletin No. 88-08, Alabama Power Company installed RTD's on all Unit 2 hot and cold leg safety injection lines, normal and alternate charging lines, pressurizer auxiliary spray line and i

l

'RCS to RHR suction lines. The installed RTD's vill be monitored during the current operating cycle for evidence of thermal cycling. The decision regarding permanent installation of the RTD monitoring system has been deferred until the end of the next refueling outage. Additionally, since l

the initiation and propagation of the crack in the Unit 2 safety injection l

piping was believed to have been caused by leakage from-the Boron Injection Tank-bypass valve, the bypass line was cut-and capped during the last refueling outage.

For Unit 1, the next refueling outage is scheduled to commence in September 1989. At that time, ultrasonic examinations vill be performed and the remaining instrumentation vill be installed'on normal and alternate charging lines,' pressurizer auxiliary spray line, and RCS to RHR suction lines. The results of these activities for Unit I will be subsequently. reported.

If there are any questions, please advise.

Respectfully submitted, ALABAMA POWER COMPANY Id k.