ML20244B910

From kanterella
Jump to navigation Jump to search

Forwards Request for Addl Info Necessary to Complete NRC Review of Licensee 820125 & 0305 Responses to IE Bulletin 80-04, Analysis of PWR Main Steam Line Break W/Continued Feedwater Addition. Response Due in 45 Days.W/O Encl
ML20244B910
Person / Time
Site: Millstone 
Issue date: 05/20/1982
From: Clark R
Office of Nuclear Reactor Regulation
To: Counsil W
NORTHEAST NUCLEAR ENERGY CO.
Shared Package
ML20053C317 List:
References
IEB-80-04, TAC-46844, NUDOCS 8206010658
Download: ML20244B910 (2)


Text

.,

)[g>g UNITED STATES NUCLEAR REGULATORY COMMISSION n

,E WASHINGTON, D. C. 20555 MAY 2 01982 s

i Docket No. 50-336 Mr. W. G. Counsil, Vice President I

Nuclear Engineering & Operations Northeast Nuclear Energy Company s

P. O. Box 270

\\

Hartford, Connecticut 06101

Dear Mr. Counsil:

We have been reviewing you[ January 25 and March 5,1980 responses I

to I&E Bulletin 80-04 on Main Steam Line Break with Continued Feedwater Addition. We find the enclosed request for additional information necessary to complete our review.

Please provide the additional information wif.hin 45 days after receipt of this request.

Contact the assigned Project Manager if you have any. questions.

Sincerely, YA Robert A. Clark, Chi f Operating Reactors Branch #3 Division of Licensi.ng

Enclosure:

Request for Additional Information cc w/ enclosure:

See next page 4

9 Lo6 car 06 TB-y A

L 3

+

u

.u

' Northeast Nuclear Enargy Company; m..

CC:"

William H. Cuddy, Es' quire '

Mr. John Shedlosky

' Day, Berry & Howard '

Resident Inspector / Millstone Counselors at Law c/o U.S.N.R.C.

One Constitution Plaza P. 0. Drawer.KK.

Hartford,. Connecticut 06103 Niantic, CT 06357 Mr.' Charles Brinkman Regional Administrator

! Manager Washington Nuclear.

Operations

Nuclear Regulatory Commission, Region.I.

s Office of Executive Director for Operatior-

,C-E' Power Systems 631~ Park Avenue Combustion Engineering, Inc.

King of Prussia, Pennsylvania 19406

' 4853' Cordell Aven., Suite A-1 Bethesda,nMD 20014 Mr. Lawrence:Bettencourt, First Selectman Town of Waterford Hall 'of Records'- 200 Boston Post Road Waterford, Connecticut 06385 Northeast Nuclear Energy Company ATTN: : Superintendent Millstone Plant

' Office of Policy & Management Post Office Box 128.

ATTN:..Under Secretary Energy Waterford, Connecticut. 06385 Division 80 Washington Street Waterford.Public Library

. Hartford,= Connecticut 06115

- Rope Ferry Road, Route 1156 Waterford, Connecticut '06385

- U. S. Environmental' Protection 'Agnecy Region'I Office

' ATTN:

Regional Radiation

, Representative 1

- John F. Kennedy Federal Building i

Boston, Massachusetts 02203 Northeast Utilities Service Company ATTN:

Mr.' Richard T. Laudenat, Manager Generation Facilities Licensing P. O. Box 270 Hartford, Connecticut 06101 eD.

O

-