ML20244B707

From kanterella
Jump to navigation Jump to search

Forwards SER Accepting Util 831103 Response to Generic Ltr 83-28,Item 4.5.2 Reactor Trip Sys Reliability - Online Testing
ML20244B707
Person / Time
Site: Fermi 
Issue date: 04/04/1989
From: Kelly L, Sylvia B
Office of Nuclear Reactor Regulation
To: Kelly L, Sylvia B
DETROIT EDISON CO.
Shared Package
ML20244B710 List:
References
GL-83-28, TAC-64104, NUDOCS 8904190346
Download: ML20244B707 (3)


Text

- _ - _ - - _ _ _ _

j'~

s r

'Apri1L4, 1989 Docket No. 50-341 i

Mr. B. Ralph Sylvia tGroup Vice President - Nuclear Operation Detroit Edison Company 6400 N. Dixie Highway

' Newport Michigan '48166

Dear Mr. Sylvia:

SUBJECT:

SAFETY EVALUATION.FOR GENERIC LETTER 83-28, ITEM 4.5.2 (REACTOR TRIP SYSTEM RELIABILITY.- ON-LINE TESTING) FOR

. FERMI-2 NUCLEAR POWER FACILITY-(TAC N0. 64104)

Generic Letter 83-28,. Item 4.5.2 required licensees and' applicants,.with plants not currently designed to permit'on-line testing of the reactor trip.

system, to justify not making modifications'to permit such testing.

By letter dated November 3,1983,'you submitted a response to. Generic Letter 83-28 Item 4.5.2.

In 'our' enclosed safety evaluation, the NRC staff concludes -

that your. response to Item 4.5.2 is acceptable. Therefore,.we consider. Item 4.5.2 to be complete.

It should be noted.that. Items 4.5.2 and 4.5.3 of Generic Letter 83-28 have -

<j.

.been assigned the,NRC Technical Assignment Control (TAC) number 64104. 1The TAC will remain open until Item 4.5.3 is closed as well.

Sincerely, originalsignedby Lynn Kelly, Project Manager Project Directorate III-1 Division of Reactor Projects III,.

IV, V and Special Projects Office of Nuclear Reactor Regulation

Enclosure:

As stated cc'w/ enc 1:

See next page DISTRIBUTION pfbl fpg y

mma.s l%'fy L/'#(

,j JStang PShuttleworth BLMozafari DLasher PD31 Gray File LA/PD31:DRSP PM/PD31: DRIP

(/ )

D31:DRSP SI [

P huttleworth LKelly/Jt$ : w TC y(v 5.NM 9

/g/89 %

g/3/89 -

/89

$/f /89 8904190346 890404 PDR ADOCK 05000341 P

PDC a=___-_______

__)

be

' p* "og i

yt

.og.

UNITED STATES y

g.

NUCLEAR REGULATORY COMMISSION

  • ^8"**[p r.fj 1989 D 2 555 l

Docket No. 50-341 I

Mr. B. Ralph Sylvia Group Vice President - Nuclear Operation Detroit Edison Company 6400 N. Dixie Highway Newport, Michigan 48166 i

Dear Mr. Sylvia:

SUBJECT:

SAFETY EVALUATION FOR GENERIC LETTER 83-28, ITEM 4.5.2

)

(REACTOR TRIP SYSTEM RELIABILITY - ON-LINE TESTING) FOR FERMI-2 NUCLEAR POWER FACILITY (TAC NO. 64104) i Generic Letter 83-28. Item 4.5.2 required licensees and applicants, with

]

plants not currently designed to permit on-line testing of the reactor trip system, to justify not making modifications to 'pemit such testing.

By letter dated November 3,1983, you submitted a response to Generic Letter 83-28, Item 4.5.2.

In our enclosed safety evaluation, the NRC staff concludes that your response to Item 4.5.2 is acceptable. Therefore, we consider Item 4.5.? to be complete.

It should be noted that Items 4.5.2 and 4.5.3 of Generic letter 83-?8 have been assigned the NRC Technical Assignment Control (TAC) number 64104. The TAC will remain open until Item 4.5.3 is closed as well.

Sincerely,

.f

.A L[

Kelly, Project, nager Project Directorate 111-1 Division of Reactor Projects I?I.

IV, Y and Special Projects l

Office of Nuclear Reactor Regulation

Enclosure:

As stated cc w/ enc 1:

1

.See next page i


_-__----__.---.a

F;n tp n'

p l

Mr. : B. Ralph Sylvia.-

Fermi-2 Facility Detroit. Edison Company cc:

Mr.-' Ronald C. Callen Ms. Lynn Goodman Adv.. Planning Review Section'.

Supervisor - Licensing Michigan Public Service. Commission Detroit Edison Company 6545 Mercantile Way Fermi Unit 2 P. O. Box 30221 6400 North Dixie Highway Lansing, Michigan 48909 Newport, Michigan 48166 John Flynn, Esq.

l Senior Attorney Detroit Edison Company '

2000 Second Avenue Detroit, Michigan 48226 Nuclear Facilities and Environmental Monitoring Section Office Division of Radiological Health.

P. O. Box 30035 Lansing, Michigan 48909 Mr. Walt Rogers U.S. Nuclear Regulatory Commission Resident Inspector's Office 6450 W. Dixie Highway Newport, Michigan 48166 Monroe County Office of Civil Preparedness-963 South Raisinville Monroe, Michigan 48161 Regi~nal Administrator, Region III o

U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 4

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _