__-_-_
Mr. Gary R. Psterson N
Sits Vice Presid:nt August 28, 1998 Catawba Nucisar Station Duke Energy Corporation 4800 Concord Road York, South Carolina 29745-9635
SUBJECT:
CATAWBA NUCLEAR STATION - RESPONSE TO NRC GENERIC LETTER 97-05, " STEAM GENERATOR TUBE INSPECTION TECHNIQUES" (TAC NOS.
MA0454 AND MA0455)
Dear Mr. Peterson:
The staff has completed its review of your response to Generic Letter 97-05, the focus of which was to verify that licensees' steam generator tube inspection practices were consistent with existing regulatory requirements and plant licensing bases. Duke Energy Corporation (Duke) submitted a response on February 24,1998, that included a description and technical bases for allinspection techniques used to size the depth of steam generator tube degradation at Catawba Nuclear Station, Units 1 and 2. The staff's review of this response did not identify any concerns with the steam generator tube inspection techniques employed at Catawba that would indicate that Duke is not in compliance with the current licensing basis for the Catawba facility.
This completes our effort on Duke's response for Catawba.
Sincerely, ORIGINAL SIGNED BY:
Peter S. Tam, Senior Project Manager Project Directorate ll-2 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation Docket Nos. 50-413 and 50-414 cc: See next page Distribution C. Ogle, Ril Docket File OGC PUBLIC LPlisco, Ril PDll-2 Reading P. Rush, O-7 D4 JZwolinski ACRS
\\
J. Guo,0-8 D1 W. Oliu, T-6 E7
/
o m
9809040088 980829 PDR ADOCK 05000413 P
PDR E
e
.. s DOCUMENT NAME: G:\\ CATAWBA \\CATA0454.LTR To r::csive a copy of this document, indicate in the box: "C" = Copy without attachment / enclosure "E" = Copy with attachment / enclosure "N" = No copy OFFICE DRPE\\PDil-2\\PM l PDil-2\\LO\\p PDJhg/M l
l NAME PTam:cn (Vfr(
LBerry \\/(\\
HBerSw
/
{ /d98 l @/S /98 DATE 08/E798
(
OFFICIAL RECORD COPY
p arto p
UNITED STATES s
j NUCLEAR REGULATORY COMMISSION t
WASHINGTON, D.C. SomsHoot
\\,,,,,*/
August 31, 1998 Mr. Gary R. Peterson Site Vice President Catawba Nuclear Station Duke Energy Corporation 4800 Concord Road York, South Carolina 29745-9635
SUBJECT:
CATAWBA NUCLEAR STATION - RESPONSE TO NRC GENERIC LETTER 97-05, ' STEAM GENERATOR TUBE INSPECTION TECHNIQUES" (TAC NOS.
MA0454 AND MA0455)
Dear Mr. Peterson:
The staff has completed its review of your response to Generic Letter 97-05, the focus of which was to verify that licensees' steam generator tube inspection practices were consistent with existing regulatory requirements and plant licensing bases. Duke Energy Corporation (Duke) submitted a response on February 24,1998, that included a description and technical bases for all inspection techniques used to size the depth of steam generator tube degradation at Catawba Nuclear Station, Units 1 and 2. The staffs review of this response did not identify any concerns with the steam generator tube inspection techniques employed at Catawba that would indicate that Duke is not in compliance with the current licensing basis for the Catawba facility.
This completes our effort on Duke's response for Catawba.
l Sincerely, j'
W Peter S. Tam, Senior Project Manager Project Directorate ll-2 Division of Reactor Projects - 1/II Office of Nuclear Reactor Regulation Docket Nos. 50-413 and 50-414 cc: See next page 1
u__ - _ _--_:_
l Catawba Nuclear Station ec:
Mr. M. S. Kitlan North Carolina Electric Membership Regulatory Compliance Manager Corporation Duke Energy Corporation P. O. Box 27306 i
4800 Concord Road Raleigh, North Carolina 27611 I
York, South Carolina 29745 Senior Resident inspector Mr. Paul R. Newton U.S. Nuclear Regulatory Commission Legal Department (PB05E) 4830 Concord Road Duke Energy Corporation York, South Carolina 29745 422 South Church Street Charlotte, North Carolina 28201-1006 Regional Administrator, Region ll U. S. Nuclear Regulatory Commission J. Michael McGarry, Ill, Esquire Atlanta Federal Center Winston and Strawn 61 Forsyth Street, S.W., Suite 23T85 1400 L Street, NW Atlanta, Georgia 30303 Washington, DC 20005 Virgil R. Autry, Director North Carolina Municipal Power Division of Radioactive Waste Management Agency Number 1 Bureau of Land and Waste Management 1427 Meadowwood Boulevard Department of Health and Environmental P. O. Box 29513 Control Raleigh, North Carolina 27626 2600 Bull Street Columbia, South Carolina 29201-1708 County Manager of York County York County Courthouse L. A. Keller York, South Carolina 29745 Manager-Nuclear Regulatory Licensing Piedmont Municipal Power Agency Duke Energy Corporation 121 Village Drive 526 South Church Street Greer, South Carolina 29651 Charlotte, North Carolina 28201-1006 Ms. Karen E. Long Saluda River Electric Assistant Attorney General P. O. Box 929 North Carolina Department of Justice Laurens, South Carolina 29360 P. O. Box 629 Raleigh, North Carolina 27602 Peter R. Harden, IV Account Manager Elaine Wathen, Lead REP Planner Energy Systems Sales Division of Emergency Management Westinghouse Electric Corporation 116 West Jones Street P. O. Box 7288 Raleigh, North Carolina 27603-1335 Charlotte, North Carolina 28241-7288 u________________._______
l
Catawba Nuclear Station cc:
Mr. T. Richard Puryear Owners Group (NCEMC)
Duke Energy Corporation 4800 Concord Road York, South Carolina 29745 Richard M. Fry, Director Division of Radiation Protection.
North Carolina Department of Environment, Health, and Natural Rescurces 3825 Barrett Drive Raleigh, North Carolina 27609-7721 i.
l
<