ML20238D808
| ML20238D808 | |
| Person / Time | |
|---|---|
| Site: | North Anna |
| Issue date: | 09/09/1987 |
| From: | Stewart W VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) |
| To: | NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM) |
| Shared Package | |
| ML20238D809 | List: |
| References | |
| 87-240A, NUDOCS 8709110407 | |
| Download: ML20238D808 (6) | |
Text
-
Tech. Spec..'6.9.1.8-
.VINGINIA EI,ucTHIC AND POWEH COMPANY li H r e n >1 o x i,). V Wb1NIA 20261 W. I., STHWAltT Vaca PummapewT -
September 9, 1987 wun.m.. ora marioma
. United States Nuclear Regulatory' Commission Serial No.
87-240A g
Attention: Document Control Desk N0/RMK:jmj Washington, D.C.
20555' Docket Nos.
50-338 50-339 License Nos.
NPF-4 NPF-7
- Gentlemen:-
VIRGINIA ELECTRIC AND POWER COMPANY' NORTH ANNA POWER STATION UNITS 1 AND 2 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT
~ Attached is a revised copy of the Annual Radiological Environmental Operating subm.tted on d
)
Report for North Anna Power Station which was originally April 30, 1987 (Serial No.87-240) in accordance with Technical Specification 6.9.1.8p A summary listing of the specific changes made to the 1986 report is
. also provided as an attachment.
.The majority.of the changes resulted from typographical errors which did not significantly. alter the data.
110 wever,
the main oversight discovered by Virginia Electfic and Power Company was that the analyses for radiofodine in well water, sur'fvce water, and food products failed to meet the Lower Limit of Detection (LLD) required by Technical' Specification Table 4-12-3.. Contrary to Section 6.9.1.8 of the North Anna' Technical' Specifications, a discussion of these analyses was not included in the 1986 Radiological Environmental Operating Report.
Measures have been taken to improve the performance in report generation and enhance the quality control of our program.
-Very truly yours, W. L. Stewart Attachment 7
N 9709110407 870909 PDR ADOCK 05000338 P
\\ \\
R PM i
i i
cc:. U. S. Nuclear Regulatory Connnission 101 Marietta Street, N.W.
Suite 2900 Atlanta, GA 30323 1
Mr. J. L. Caldwell
'NRC Senior Resident inspector North Anna Power Station i
l J
I-I l
L___________________
(L J
i i
, e t
ATTACRMENT
SUMMARY
' LISTING OF SPECIFIC l
CHANGES TO THE 1986 RADIOLOGICAL ENVIRONMENTAL OPERATING REPCRT i
l l
- ^ - -
.m-__-.m____
s I
l 1
CHANCES TO THE 1986 NORTH ANNA RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT 1..
Page 8, Station V-25/27 changed to read W-25/57 for the NAPS Radio j
Tower.
q 2.
Page 26, Second par.. second sentence.
Table 65 changed to read Table 6.
3.
Page'37, Table 5.
Under STA-07, footnote (e) changed to footnote (d).
4.
Page 47, TabJe 10.
The average concentration of Sr-90 changed to 163 t 6_1,pCi/kg.
5.
Page 55, Second Par.
The average level of tritium at station W-33 changed to 3130 pCi/1.
6.
Page 79, a.-
First par., fifth sentence. The average concentration of bery111um-7 changed to 406 pCi/kg.
b.
First. par., sixth sentence.
The upper range for thorium-228 is changed from 235 pC1/kg to 407 pC1/kg.
c.
Second par., fourth sentence. Cesium-134 changed to Cesium-137.
7.
Page 82, a.
First par., fourth sentence.
The average dose changed to 5.7 mR/
standard month, b.
First par., fifth sentence.
The control station, No. 24 had u average reading of 5.1 mR/ standard month with a range of 4.4 to 6.1 mR/ standard month.
'8.
Page 93, a.
Second par., fifth sentence.
The level of tritium monitored at the discharge lagoon was 3130 pC1/1 and 1183 pCi/1 upstream of the plant.
b.
The third paragraph was restated:
" Ground water from the environmental well on site contained no gamma emitters.
The average level of tritium in ground /well water is 198 pCi/1 which.is a low environmental level.
9.
Page 95, Second par.
5.8 mR per month was changed to 5.7 mR per month.
CAT /pb:55/036 _ - _ _ _ _ _ _ - _ _ _ _
e 6
10.
For each of the LLDs which were not achieved for the radioiodine analyses
. performed on river water, surface water,.and food product samples, the reason why the LLD ' was not met has been documented in the appropriate report tables (Tables 12, 17, and 27).
The explanation.for the failure-to meet the required LLDs is included in Section 3 of the report and the
-appropriate samples have been added to the ?EMP Exceptions Table.
'l n-
- r h
1 CAT /ph S5/036 ;l i
b
r i 3 6 V ii d!S L8bi l
SG-0UNSO l
q
. - - _ - _ - - - - _ _ _ - _ _ -