ML20238D751
| ML20238D751 | |
| Person / Time | |
|---|---|
| Site: | 05000139 |
| Issue date: | 08/28/1987 |
| From: | Wenslawski F NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) |
| To: | Jeremy Bowen WASHINGTON, UNIV. OF, SEATTLE, WA |
| Shared Package | |
| ML20238D753 | List: |
| References | |
| NUDOCS 8709110374 | |
| Download: ML20238D751 (2) | |
See also: IR 05000139/1987001
Text
.
_-_
.
.
yy
7
4
b,'
.. .
.
AUG.281987
- Docket.No. 50-139
i
!
University of Washington
1..
Seattle, Washington 98195
'
Attention:
J. Ray Bowen, Dean
. College of Engineering FH-10
Gentlemen:
-
SUBJECT:
NRC INSPECTION'
This report refers to the~ routine inspection conducted by Mr. M. Cillis of
i
this office on July 27-28, 1987, of activities authorized by NRC License No.
1
R-73, and to'the discussions of our findings held by Mr. Cillis with Dr. M. A.
Robkin and other members of your staff at the conclusion of the inspection.
. Areas examined during this inspection are described in the enclosed inspection-
report.' 'Within these areas, the inspection consisted of selective
'
examinations-of procedures and representative records, interviews with
personnel, and observations by the: inspector.
Based on the results'of this inspection, it appears that certain of your
i
activities were not conducted in full compliance with NRC requirements, as set
forth in the Notice of Violation, enclosed herewith as Appendix A.
.
Your response to this Notice is to be submitted in accordance with the
i
provisions of 10 CFR 2,201 as stated in Appendix A, Notice of Violation.
. Based on telephone discussion with.Dr. Miller of your staff on August 27,
i
1987, we understand that in your' response to the Notice.of Violation you will
,
also describe the supplementary control rod drop time surveillance. tests you
will be performing and how you will communicate the results of these tests
and your evaluation to NRC.
.
In accordance with 10 CFR 2.790(a), a copy of this letter and the enclosure
will be placed in the NRC Public Document Room.
The responses directed by this letter and the accompanying Notice are not
subject to the clearance procedures of the Office of Management and Budget as
required by the Paperwork Reduction Act of 1980, PL 96-511.
~
Should'you have any questions concerning this inspection, we will be glad to
discuss them.with you.
Sincerely,
+Q
fx.t/
F.
. Wenslawski, Chief
Radiological Protection Branch
[ {
91{0 g g7
9
Q
'IE06
_
- - -
.
.
AUG 281987
.g.
Enclosures:
A.
Appendix A - Notice of Violation
B.
Inspection Report No. 50-139/87-01
cc w/ enclosures:
State of Washington
bec w/ enclosures:
I
RSB/ Document Control Desk (RIDS) (IE06)
j
G. Cook
B. Faulkenberry
J. Martin
Docket File
bec w/o enclosure B:
LFMB
M. Smith
Region V
[ RJ, QUEST COPY ] RQUEST COPY ] REQUEST JO}Y ] REQUESTY]
[(?ES) / NO
] YES)_/ NO
] YES / /N4
] YES / NO,
]
~~
"
[
T07DR ]
[ YE
/ NO ]
~W
'
MCiT1' / norma
GYuhas
AJob son
FAWenslawski
8M /87
8At/87
8/M/87
8/)f/87
l
1
l
I
______ - __ _ -