l September 3, 1987 I
In Reply Refer To:
Dockets: 50/445/86-26 50/446/85-22 1
TU Electric ATTN:
Mr. W.
G.
Counsil i
Executive Vice President I
400 North Olive, Lock Box 81 l
Dallas, Texas 75201 l
Gentlemen:
Thank you for your letters dated June 5, 1987, and July 13, 1987,
)
in responee to our letter dated April 2, 1987.
As a result of l
our review, we find that additional information with respect to l
Items B and C in the Notice of Deviation (NOD) is needed.
The j
requested information has been discussed in meetings with Mr.
John Streeter and other members of your staff on August 13 and 20, t
l 1987.
Your response to Item B of the NOD indicates disagreement with j
l the stated deviation.
Your response, however, fails to recognize I
that the ISAP I.d.3 requirements were being ilaplemented prior to l
l the SRT approval or issuance of the Results Report.
Accordingly, we request that you provide the information originally requested for this deviation.
Your response to Item C of the NOD does not address how the SRT was aware of ISAP changes which were made in the Results Reports.
In addition, you state corrective action was taken with the SRT on May 20, 1987.
Either this date is in error or your corrective actions were not timely.
Therefore, we request that you revise your response to this deviation to address the above two
- concerns, Please provide the requested information within 20 days of the date of this letter, f)
OSP:CPPD:IP IP: M IP:
IP: RFSMAD:IP /2M PWagner:ww LEl s aw CHal-IBarnes RWarnick 9/) /87
" Y 9/J/87 9/J/87 9/9 /87 9/J/87 1
8709100461 8709d3 PDR ADOCK 05000445 G
PDR J
i s
TU Electric 2
September 3, 1987 With respect to NOD Item D, we have no further. questions at this time.
We acknowledge your disagreement with this deviation; however, we will be reviewing the additional information you provided in conjunction with the inspection of'your activities in the HVAC ares under the Corrective Action Program.
We have no further questions regarding your response to the remaining violations, deviations, or the unresolved item, and will review the implementation of your corrective actions during future inspections.
Sincerely, CLIG12."' E ' ' O 27 1 I' '" " Z '-
R. F. Warnick, Assistant Director for Inspection Programs
]
Comanche Peak Project Division i
Office of Special Projects cc:
See next page
- CICu%
L g[~
,'t NUCLEAR REGULATORY COMMISSION UNITED STATES g
WASHINGTON, D. C. 20555 e
o.,
4
/
- ++
September 3, 1987 I
l In heply Refer To:
l Dockets: 50/445/86-26 50/446/86-22
)
TU Electric ATTN:
Mr. W. G. Counsil i
Executive Vice President j
400 North Olive, Lock Box 81 Dallas, Texas 75201 l
Gentlemen:
Thank you for your letters dated June 5, 1987, and July 13, 1987, in response to our letter dated April 2, 1987.
As a result of our review, we' find that additional information with~ respect to Items B and C in the Notice of Deviation (NOD) is needed.
The 1
requested information has been discussed in meetings uith Mr.
l John Streeter and other members of your staff on August 13 and 20, 1
1987.
Your response to Item B of the NOD indicates disagreement with the stated deviation.
Your response, however, fails to recognize that the ISAP I.d.3 requirements were being implemented prior to the SRT approval or issuance of the Results Report.
Accordingly, we request that you provide the information originally requested for this deviation.
Your response to Item C of the NOD does not address how the SRT l
was aware of ISAP changes which were made in the Results Reports.
i In addition, you state corrective action was taken with the SRT l
on May 20, 1987.
Either this date is in error or your corrective i
actions were not tbnely.
Therefore, we request that you revise your response to this deviation to address the above two Concerns.
Please provide the requested information within 20 days of the date of this letter.
)
i
)
i
1
(
i TU Electric 2
September 3, 1987
{
l I
With respect to NOD Item D, we have no further questions at this time.
We acknowledge your disagreement with this deviation; however, we will be reviewing the additional information you provided in conjunction with the inspection of your activities in j
the HVAC aret under the Corrective Action Program.
We have no further questions regarding your response to the remaining violations, deviations, or the unresolved item, and will review the implementation of your corrective actions during future I
inspections.
i Sincerely, RFLUw d-R. F. Warnick, Assistant Director for Inspection Programs l
Comanche Peak Project Division Office of Special Projects CC:
j See next page l
l i
i
)
4 TU Electric 3
cc w/ enclosure:
TU Electric Bureau of Radiation Control ATTN:
G. S. Keeley, Manager State of Texas Nuclear Licer.cing Skyway Tower 1100 West 49th Street Austin, Texas 78756 400 North Olive Street, L.B.81 Dallas, Texas 75201 Nancy H. Williama Juanita Ellis CYGNA Energy Services Suite 390 President - CASE 1426 South Polk Street 2121 N. California Blvd Walnut Creek, CA 94596 Dellas, Texas 75224 Renea Hicks, Esq.
Assistant Attorney General Environmental Protection Division P.O. Box 12548, Capitol Station Austin, Texas 78711-2548 Administrative Judge Peter Bloch U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Elizabeth B. Johnson Administrative Judge Oak Ridge National Laboratory Post Office Box X, Building 3500 i
Oak Ridge, Tennessee 37830 Dr. Kenneth A. McCollom 1107 West Knapp Stillwater, Oklahoma 74075 Dr. Walter H. Jordan Administrative Judge 881 West Outer Drive Oak Ridge, Tennessee 37830 Anthony Z. Roisman, Esq.
Suite 600 1401 New York Avenue, N.W.
Washington, D.C.
20005 Ms. Billie Pirner Garde, Esq.
Government Accountability Project Midwest Office 104 East Wisconsin Avenue Appleton, Wisconsin 54911 l
,.. D1HTELQTE19.E::... ~.. -,,..
A Docket. Files 0.. ( 50-4. 45/446 ).; NRC ' PDRt' p
CPPD Reading (HQ)
- Site Reading
- CPRT Group
- SRI-OPS
- SRI-CONST
- MIS System
- RSTS Operator RPB RIV File
- w/766 1