Category:MONTHLY OPERATING ANALYSIS REPORT
MONTHYEARML20217K4631999-09-30030 September 1999 Monthly Operating Rept for Sept 1999 for Nine Mile Point, Unit 1.With ML20212C4601999-08-31031 August 1999 Monthly Operating Rept for Aug 1999 for Nine Mile Point Nuclear Station,Unit 1.With ML20210U4591999-07-31031 July 1999 Monthly Operating Rept for July 1999 for Nine Mile Point, Unit 1.With ML20210B9081999-06-30030 June 1999 Monthly Operating Rept for June 1999 for Nine Mile Point Unit 1.With ML20196E2111999-05-31031 May 1999 Monthly Operating Rept for May 1999 for Nmp,Unit 1.With ML20196L2301999-04-30030 April 1999 Monthly Operating Rept for Apr 1999 for Nmp,Unit 1.With ML20205S5701999-03-31031 March 1999 Monthly Operating Rept for Mar 1999 for NMP Unit 1.With ML20204C9971999-02-28028 February 1999 Monthly Operating Rept for Feb 1999 for Nine Mile Point,Unit 1.With ML20199K9331998-12-31031 December 1998 Monthly Operating Rept for Dec 1998 for Nine Mile Point Nuclear Station,Unit 1.With ML20198D9361998-11-30030 November 1998 Monthly Operating Rept for Nov 1998 for Nine Mile Point,Unit 1.With ML20195J4141998-10-31031 October 1998 Monthly Operating Rept for Oct 1998 for Nine Mile Point Nuclear Station,Unit 1.With ML20154P1821998-09-30030 September 1998 Monthly Operating Rept for Sept 1998 for Nine Mile Point Nuclear Station,Unit 1.With ML20153B2001998-08-31031 August 1998 Monthly Operating Rept for Aug 1998 for Nmpns,Unit 1.With ML20237C6351998-07-31031 July 1998 Monthly Operating Rept for July 1998 for Nine Mile Point Nuclear Station,Unit 1 ML20236Q1701998-06-30030 June 1998 Monthly Operating Rept for June 1998 for Nine Mile Point Nuclear Station,Unit 1 ML20249B4971998-05-31031 May 1998 Monthly Operating Rept for May 1998 for Nine Mile Point Nuclear Station,Unit 1 ML20247R1141998-04-30030 April 1998 Monthly Operating Rept for Apr 1998 for Nine Mile Point Nuclear Station,Unit 1 ML20217B0621998-03-31031 March 1998 Monthly Operating Rept for Mar 1998 for Nine Mile Point Nuclear Station,Unit 1 ML20217B5371998-02-28028 February 1998 Monthly Operating Rept for Feb 1998 for Nine Mile Point Nuclear Station,Unit 1 ML20203A3071998-01-31031 January 1998 Monthly Operating Rept for Jan 1998 for Nine Mile Point Nuclear Station,Unit 1 ML20198T0601997-12-31031 December 1997 Monthly Operating Rept for Dec 1997 for Nine Mile Point Nuclear Station,Unit 1 ML20197B4531997-11-30030 November 1997 Monthly Operating Rept for Nov 1997 for NMP Nuclear Station, Unit 1 ML20199H3131997-10-31031 October 1997 Monthly Operating Rept for Oct 1997 for NMP Nuclear Station, Unit 1 ML20212A7001997-09-30030 September 1997 Monthly Operating Rept for Sept 1997 for Nine Mile Point Nuclear Station,Unit 1 ML20211A4981997-08-31031 August 1997 Monthly Operating Rept for Aug 1997 for Nine Mile Point Nuclear Station Unit 1 ML20217M4101997-07-31031 July 1997 Monthly Operating Rept for July 1997 for NMPNS ML20141H1921997-06-30030 June 1997 Monthly Operating Rept for June 1997 for Nine Mile Point Nuclear Station,Unit 1 ML18037A1361997-04-30030 April 1997 Monthly Operating Rept for Apr 1997 for Nine Mile Point Nuclear Station,Unit 1 ML17059B5541997-03-31031 March 1997 Revised Monthly Operating Rept for Mar 1997 for Nine Mile Point Nuclear Station,Unit 1 ML17059B5531997-02-28028 February 1997 Revised Monthly Operating Rept for Feb 1997 for Nine Mile Point Nuclear Station,Unit 1 ML18037A1351996-10-31031 October 1996 Monthly Operating Rept for Oct 1996 for Nine Mile Point, Unit 2.W/961115 Ltr ML18038A5001991-12-31031 December 1991 Monthly Operating Rept for Dec 1991 for Unit 2 Shutdowns & Power Reductions.W/920115 Ltr ML18038A3541991-05-31031 May 1991 Narrative Rept of Operating Experience for May 1991 for Nine Mile Point Nuclear Station Unit 1 ML17058A8061991-05-31031 May 1991 Monthly Operating Rept for May 1991 for Nine Mile Point Nuclear Station Unit 1 ML17058A7071991-03-31031 March 1991 Monthly Operating Rept for Mar 1991 for Nine Mile Point Unit 1 ML17058A7091991-02-28028 February 1991 Corrected Monthly Operating Rept for Feb 1991 for Nine Mile Point Unit 1 ML18038A3401991-01-31031 January 1991 Monthly Operating Rept for Jan 1991 for Nine Mile Point Nuclear Station Unit 1 ML18038A3421990-12-31031 December 1990 Revised Monthly Operating Rept for Dec 1990 for Nine Mile Point Nuclear Station Unit 1 ML18038A3391990-12-31031 December 1990 Monthly Operating Statistics Rept for Dec 1990 for Nine Mile Point Unit 2.Narrative Rept of Operation Experience for Dec 1990 encl.W/910111 Ltr ML17056B2961990-11-30030 November 1990 Revised Monthly Operating Rept for Nov 1990 for Nine Mile Point Nuclear Station Unit 1 ML17056B2971990-10-31031 October 1990 Revised Monthly Operating Rept for Oct 1990 for Nine Mile Point Nuclear Station Unit 1 ML17056B2981990-09-30030 September 1990 Revised Monthly Operating Rept for Sept 1990 for Nine Mile Point Nuclear Station Unit 1 ML17056B2991990-08-31031 August 1990 Revised Monthly Operating Rept for Aug 1990 for Nine Mile Point Nuclear Station Unit 1 ML17056B3001990-07-31031 July 1990 Revised Monthly Operating Rept for Jul 1990 for Nine Mile Point Nuclear Station Unit 1 ML17056B3011990-06-30030 June 1990 Revised Monthly Operating Rept for June 1990 for Nine Mile Point Nuclear Station Unit 1 ML20043H5261990-05-31031 May 1990 Monthly Operating Rept for May 1990 for Nine Mile Point, Unit 2.W/900614 Ltr ML17056B3021990-05-31031 May 1990 Revised Monthly Operating Rept for May 1990 for Nine Mile Point Nuclear Station Unit 1 ML17056B3031990-04-30030 April 1990 Revised Monthly Operating Rept for Apr 1990 for Nine Mile Point Nuclear Station Unit 1 ML17056B3041990-03-31031 March 1990 Revised Monthly Operating Rept for Mar 1990 for Nine Mile Point Nuclear Station Unit 1 ML17056B3051990-02-28028 February 1990 Revised Monthly Operating Rept for Feb 1990 for Nine Mile Point Nuclear Station Unit 1 1999-09-30
[Table view] Category:TEXT-SAFETY REPORT
MONTHYEARML20217G2161999-10-15015 October 1999 Errata Pages 2 & 3 for Safety Evaluation Supporting Amend 168 Issued to FOL DPR-63 Issued on 990921.New Pages Change Description of Flow Control Trip Ref Cards to Be Consistent with Application for Amend ML20217K4631999-09-30030 September 1999 Monthly Operating Rept for Sept 1999 for Nine Mile Point, Unit 1.With ML20216J9251999-09-30030 September 1999 Suppl to Special Rept:On 990621,11 Containment Hydrogen Monitoring Sys Chart Recorder Was Indicating Below Normal Operating Range.Caused by Excessive Wear on Valve Body & Discs of Bypass Pump.Sample Pump Replaced ML20212F7301999-09-21021 September 1999 Special Rept:On 990907,CR Operators Declared 12 Containment Hydrogen Monitoring Sys Inoperable for Planned Maint.Cause of Low Flow Condition Was Determined to Be Foreign Matl. Replaced Sample Pump Valve Discs ML20212B9081999-09-14014 September 1999 Special Rept:On 990901, 12 Containment Hydrogen Monitoring Sys Was Declared Inoperable for Planned Maint.Caused by Planned Maint Being Performed as Corrective Action.Check Valves with O Rings Were Replaced ML20212C4601999-08-31031 August 1999 Monthly Operating Rept for Aug 1999 for Nine Mile Point Nuclear Station,Unit 1.With ML20216F5141999-08-31031 August 1999 Rept on Status of Public Petitions Under 10CFR2.206 ML20210U4591999-07-31031 July 1999 Monthly Operating Rept for July 1999 for Nine Mile Point, Unit 1.With ML20209D0291999-07-0202 July 1999 Special Rept:On 990621,operator Identified That Number 11 Hydrogen Monitoring Sys (Hms) Chart Recorder Was Indicating Below Normal Operating Range.Cause Indeterminate.Licensee Will Complete Troubleshooting of Subject Hms by 990709 ML20210B9081999-06-30030 June 1999 Monthly Operating Rept for June 1999 for Nine Mile Point Unit 1.With ML20209F8811999-06-0808 June 1999 Rev 1 to NMP Unit 1 COLR for Cycle 14 ML20207G2261999-06-0707 June 1999 SER Accepting Proposed Mod to Each of Four Core Shroud Stabilizers for Implementation During Current 1999 Refueling Outage at Plant,Unit 1 ML20196E2111999-05-31031 May 1999 Monthly Operating Rept for May 1999 for Nmp,Unit 1.With ML20207B0241999-05-18018 May 1999 Safety Evaluation of Topical Rept TR-107285, BWR Vessel & Intervals Project,Bwr Top Guide Insp & Flaw Evaluation Guidelines (BWRVIP-26), Dtd December 1996.Rept Acceptable ML20206U5351999-05-17017 May 1999 SER Accepting GL 95-07, Pressure Locking & Thermal Binding of Safety-Related Power-Operated Gate Valves, for Plant, Units 1 & 2 ML20196L2301999-04-30030 April 1999 Monthly Operating Rept for Apr 1999 for Nmp,Unit 1.With ML20205L0541999-04-0101 April 1999 Nonproprietary Replacement Pages to HI-91738,consisting of Section 5.0, Thermal-Hydraulic Analysis ML20205S5701999-03-31031 March 1999 Monthly Operating Rept for Mar 1999 for NMP Unit 1.With ML20207M9231999-03-12012 March 1999 Amended Part 21 Rept Re Cooper-Bessemer Ksv EDG Power Piston Failure.Total of 198 or More Pistons Have Been Measured at Seven Different Sites.All Potentially Defective Pistons Have Been Removed from Svc Based on Encl Results ML20207G2671999-03-0101 March 1999 Special Rept:On 990315,Nine Mile Point,Unit 1 Declared Number 12 Containment Hydrogen Monitoring Sys Inoperable. Caused by Degraded Encapsulated Reed Switch within Flow Switch FS-201.2-1495.Technicians Replaced Flow Switch ML20204C9971999-02-28028 February 1999 Monthly Operating Rept for Feb 1999 for Nine Mile Point,Unit 1.With ML20207E9311999-02-26026 February 1999 Part 21 Rept Re Sprague Model TE1302 Aluminum Electrolytic Capacitors with Date Code of 9322H.Caused by Aluminum Electrolytic Capacitors.Affected Capacitors Replaced ML17059C5501999-01-31031 January 1999 Rev 0 to MPR-1966(NP), NMP Unit 1 Core Shroud Vertical Weld Repair Design Rept. ML20199M0891999-01-22022 January 1999 Part 21 Rept Re Failure of Square Root Converters.Caused by Failed Aluminum Electrolytic Capacitory Spargue Electric Co (Model Number TE1302 with Mfg Date Code 9322H).Sent Square Root Converters Back to Mfg,Barker Microfarads,Inc ML20199K9331998-12-31031 December 1998 Monthly Operating Rept for Dec 1998 for Nine Mile Point Nuclear Station,Unit 1.With ML20210R8441998-12-31031 December 1998 1998 Annual Rept for Energy East ML20206P2391998-12-31031 December 1998 Special Rept:On 981222,operators Removed non-TS Channel 12 Drywell Pressure Recorder & Associated TS Pressure Indicator from Svc.Caused by Intermittent Measuring Cable Connection in non-TS Recorder Circuitry.Replaced Cable ML20206P2421998-12-30030 December 1998 Special Rept:On 981219,number 12 Hydrogen Monitoring Sys (Hms) Was Declared Inoperable When Operators Closed Valve 201.2-601.Caused by Indeterminate Failure of Valve 201.2-71. Supplemental Rept Will Be Submitted After Valve Is Repaired ML20198M3571998-12-23023 December 1998 Special Rept:On 981210,operators Declared Number 11 Inoperable,Due to Failure of CR Chart Recorder.Caused by Inverter Board in Power Supply Circuitry of Recorder Due to Component Aging.Maint Personnel Replaced Failed Inverter ML20198D9361998-11-30030 November 1998 Monthly Operating Rept for Nov 1998 for Nine Mile Point,Unit 1.With ML20155E2001998-11-0202 November 1998 Safety Evaluation Approving NMP 980227 Request for Extension of Reinspection Interval for Core Shroud Vertical Welds at NMP1 from 10,600 Hours to 14,500 Hours of Hot Operation ML20195J4141998-10-31031 October 1998 Monthly Operating Rept for Oct 1998 for Nine Mile Point Nuclear Station,Unit 1.With ML20154D8401998-10-0505 October 1998 Safety Evaluation Accepting Proposed Changes Related to PT Limits in Plant,Unit 1 TSs ML20154P1821998-09-30030 September 1998 Monthly Operating Rept for Sept 1998 for Nine Mile Point Nuclear Station,Unit 1.With ML20153B2001998-08-31031 August 1998 Monthly Operating Rept for Aug 1998 for Nmpns,Unit 1.With ML20237C6351998-07-31031 July 1998 Monthly Operating Rept for July 1998 for Nine Mile Point Nuclear Station,Unit 1 ML20236T5911998-07-20020 July 1998 LER 98-S01-00:on 980618,security Force Member Left Nine Mile Point,Unit 2 Vehicle Gate Unattended Without Ensuring,Gate Alarm Had Been Reactivated.Caused by Inadequate Work Practice.Vehicle Gate Alarm Was Activated ML18040A3491998-07-0202 July 1998 LER 98-017-00:on 980602,control Room Ventilation Sys Was Declared Inoperable.Caused by Original Design Deficiency. Mod Designed,Tested & Implemented Prior to Startup from RF06 to Correct Design deficiency.W/980702 Ltr ML20236Q1701998-06-30030 June 1998 Monthly Operating Rept for June 1998 for Nine Mile Point Nuclear Station,Unit 1 ML17059C1011998-06-24024 June 1998 LER 98-014-00:on 980525,noted Differences Between Actual Valve Weights & Weights Shown on Engineering Drawings.Caused by Vendor Failing to Provide Accurate Valve Weights.Revised Valve Drawings & Associated Calculation,Per 10CFR21 ML20151P1751998-06-16016 June 1998 Rev 0 to SIR-98-067, Evaluation of NMP Unit 2 Feedwater Nozzle-to-Safe End Weld Butter Indication (Weld 2RPV-KB20, N4D) ML18040A3451998-06-0404 June 1998 LER 98-004-01:on 980302,TS Required LSFT of Level 8 Trip of Main Turbine Was Missed.Caused by Knowledge Deficiency of EHC Sys.Revised Applicable LSFT Procedures Prior to Refueling Outage 6.W/980604 Ltr ML20249B4971998-05-31031 May 1998 Monthly Operating Rept for May 1998 for Nine Mile Point Nuclear Station,Unit 1 ML20248F3531998-05-21021 May 1998 Part 21 Rept Re Electronic Equipment Repaired or Reworked by Integrated Resources,Inc from Approx 930101-980501.Caused by 1 Capacitor in Each Unit Being Installed W/Reverse Polarity. Policy of Second Checking All Capacitors Is Being Adopted ML20198B4991998-05-15015 May 1998 Non-proprietary Replacement Pages for Attachment F to Which Proposed to Change TS 5.5, Storage of Unirradiated & Sf ML20247R1141998-04-30030 April 1998 Monthly Operating Rept for Apr 1998 for Nine Mile Point Nuclear Station,Unit 1 ML20217B0621998-03-31031 March 1998 Monthly Operating Rept for Mar 1998 for Nine Mile Point Nuclear Station,Unit 1 ML17059C1681998-03-19019 March 1998 Revised Niagara Mohawk Powerchoice Settlement Document for NMPC PSC Case Numbers 94-E-0098 & 94-E-0099, Vols 1 & 2 ML20217F4341998-03-19019 March 1998 SER Related to Proposed Restructuring New York State Electric & Gas Corp,Nine Mile Point Nuclear Station,Unit 2 ML17059B9051998-02-28028 February 1998 NMP Unit 1 Boat Samples Analyses Part Iii:Tension Tests, RDD:98:55863-004-000:01 1999-09-30
[Table view] |
Text
R
} .
I OPERATING DATA REPORT I DOCKET NO. 50-220 DATE 5/6/8/
COMPLETED BY W. Roman TELEPHONE 3 3-3 C 422 OPERATING STATUS
- 1. Unit Name:
Nine Mile Point Unit 1 Notes 4/1/6/ titrougli 4/avise
- 2. Reporting Period:
1850
- 3. Licensed Thermal Power (MWt): ;
- 4. Nameplate Rating (Gross MWe):
640 -
D
- 5. Design Electrical Rating (Net MWe):
600
- 6. Maximum Dependable Capacity (Gross MWe):
- 7. Maximum Dependable Capacity (Net MWe): -
l 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report. Give Reasons:
- 9. Power Level To Which Restricted,If Any (Net MWe):
- 10. Reasons For Restrictions,if Any:
i This Month Yr. to-Date Cumulative 1
- 11. Hours In Reporting Period 719.0 2879.3 154,464.2
- 12. Number Of Hours Reactor Was Critical 719.0 2679. I I W , N .1 i
- 13. Reactor Reserve Shutdown Hours 0.0 0.0 1,204.2 j
- 14. Hours Generator On-Line 719.0 2879.0 106,obb./
)
- 15. Unit Reserve Shutdown Hours 0.0 0.O E4
- 16. Gross Thermal Energy Generated (MWH) 1,314.463.0 5,276,080.0 179,527,125.0 17 Gross Electrical Energy Generated (MWH) 448,193.0 1,804,172.0 59,525,925.0 j
- 18. Net Electrical Energy Generated (MWH) 435,837.0',, 1,753,075.0 57,562,260.0 '
- 19. Unit Service Factor 100.0 100.0 W.J
- 20. Unit Availability Factor 100'U A**" "
- 21. Unit Capacity Factor (Using MDC Net)
- 22. Unit Capacity Factor (Using DER Net) 9'*D ""# DU*I
- 23. Unit Forced Outage Rate
'" "'" "'# I
- 24. Shutdowns Scheduled Over Next 6 Months (Type. Date.and Duration of Each): :
I i
- 25. If Shut Down At End Of Report Period. Estimated Date of Startup:
I 26. Units in Test Status (Prior to Commercial Operation): Forecast Achieved INITIA L CRITICALITY INITIA L ELECTRICITY COMMERCIAL OPER ATION f
8708190198 870430 ,m77, fg\
PDR ADOCK 05000220 R PDR
- - _ - _ _ _ _ _ =
AVER \GE D AILY UNIT POhER LEVEL I
DOCKETNO. 50 220
(
UNIT Nine Mile Pt i D\TE 5/6/87 CO\tPLE TED ilY T. W. Rornan l
TELEPil0NE (315) 349-2422
{
.\tONTH APRIL 1987 DAY AVERACE D Al Y VER LEVEL DAY AVER ACE DAILY POWER LEVEL
(.\lWe Net) l 1 606 611 )
2 6 14 gg 611 3 -611 - .
612 19 4 612 20 613 )
5 f) M 613 21 6 6 14 ,, 611 !
.. l 7 f'? -
o13 23 8 6fl 573
,4 9 6f3 610 -
25 to 610 609
'6 1!
515 . , . 613 12 W :s 609 33 612 , 612 14 6 i '~
30 611 15 6l3' 3l 16 6 14 INSTR UCTIONS l
. " e"l,i'"a'sO?' "'""" n~"~' "> "* x-~">>mn ", ,. >,. n.- ,,; , .,
1
.-.___.--________.___J
! l i
NIAGARA MORAWK POWER CORPORATION l I
NINE MILE POINT NUCLEAR STATION UNIT #1 l NARRATIVE OF OPERATING EXPERIENCE l
The station operated during the month of April 1987 with a Unit Availability )
Factor of 100.0% and a Net Design Electrical Capacity Factor of 97.87.. There '
were no challenges to Electromatic Relief Valves. Reductions in Capacity Factor were due to weekly Control Rod Exercising and CRD Module maintenance. Also, adjustments were made to the Control Rod pattern including a Sequence Exchange. l l
CLASS I WORK - MECHANICAL MAINTENANCE - APRIL 1987 1
WR # 106219 System 44, Component 30-11. CRD 30-11 Accumulator Foot Valve, j i
replaced 0-rings and stem packing l l l l
l WR # 106225 System 44, Component 30-11. Control Rod Drive Accumulator 30-11, l replaced water accumulator.
1 WR # 100218 System 72, Component SW317. 13 Rx Building CLC Heat Exchanger, l install new nipple. l WR # 111528 System 44, Component 22-31. CRD 22-31, replaced operator diaphragm.
WR # 111527 System 44, Component 22-31. CRD 22-31, replaced operator diaphragm.
WR # 109409 System DG, Component DG-102. DG-102 Crankcase Pressure, no failure, work was done for troubleshooting.
WR # 106235 System 44, Component 44-CRD. Accumulator 30-39, Footvalve leaks N , replace packing, 0-rings, teflon gasket.
2 WR # 100220 System 44, Component 30-31. CRD #30-31, replace 127 valve diaphragm WR # 100219 System 44, Component 30-23. CRD #30-23, replaced diaphragm.
WR # 100221 System 44, Component 30-31. CRD #30-31, replace parts, replace diaphragm.
WR # 106239 System 44, Component 111. CRD # 30-31, Foot Valve (# 111), re-placed packing, 0-rings and teflon back-up ring.
WR # 100236 System 44, Component, 22-23. CRD #22-23, replace the diaphragm.
WR # 100235 System 44, Component 22-23. CRD #22-23, replace the diaphragm.
l NARRATIVE OF OPERATING EXPERIENCE 3 May 11, 1987 ,
Page 2 !
1 l
CLASS I WORK - MECHANICAL MAINTENANCE - APRIL 1987 (Cont.) l l
WR # 100237 System 44, Component 30-23. CRD #30-23, replace the diaphragm. J WR # 100239 System 44, Component Spare. H 0-N Accumulator (on 237'),
2 2 rebuilt accumulator. j l
WR # 100242 System 44, Component Spare. H 0-N 2 2 Accumulator (on 237'), i rebuilt accumulator.
WR # 100238 System 44, Component Spare. Hy 0-N 2 Accumulator (on 2M'), i rebuilt accutnulator. ]
WR # 100240 System 44, Component Spare. H 0-N Accumulator (on 237'),
2 2 rebuilt accumulator.
WR # 100241 System 44, Component Spare. -H 0-N Accumulator (on 237'), j 2 2 l
rebuilt accumulator. !
l 4
WR # 106238 System RXBM, Component Peele (D198). Pee' e Door (Rx-261 '), j repair part.
WR # 100222 System 210, Component 11. 111 Chiller Compressor, replace bolts.
WR # 112011 System 44, Component 50-19. CRD 50-19, void - work being done ]
on WR # 111539. ;
WR # 112034 System 44, Component 50-19. Rebuilt accumulator. )
i WR # 111539 System 44, Component 50-19. CRD 50-19 Directional Control l Man i fold ,' . replaced old filter.
l.
CLASS I WORK - ELECTRICAL MAINTENANCE - APRIL 1987 WR # 112039 Electrical Miscellaneous, MG 172, Retaped Generator Leads. 1 CLASS I WORK - INSTRUMENT AND CONTROL - APRIL 1987 WR # 106279 Wide range level F panel - blew down wide range level.
l WR # 111535 CRD 22-23, inspect & replace the 126 valve diaphragm. Retimed
! valve stroke ;
WR # 111534 CRD 22-23, inspect & replace the 127 valve diaphragm. Retimed ,
valve stroke. l l !
WR # 100236 CRD 22-23, replace 126 valve diaphragm. A pre 6 post valve time 1 l taken by 16C. ;
WR # 100235 CRD 22-23, replace 127 valve diaphragm. A pre and post valve l time taken by I6C. !
I i
NARRATIVE OF OPERATING EXPERIENCE !
May 1i, 1987 Page 3 CLASS I WORK - INSTR F,NT AND CONTROL - APRIL 1987 (Cont.)
WR # 111527 CRD 22-31, remove, inspect and replace the 126 valve diaphragm.
Retimed valve stroke.
WR # 111528 CRD 22-31, remove, inspect and replace the 127 valve diaphragm. 1 Retimed valve stroke. I WR # 106213 Scram inlet valve diaphragm blosm on 30-39 CRD, replace scram i inlet valve air diaphragm and retime valve stroke. l I
WR # 111530 CRD 30-23, remove, inspect and replace the 127 valve diaphragm. !
Retimed valve stroke. l l
WR # 111529 CRD 30-23, remove, inspect and replace the 126 valve diaphragm. f Retimed valve stroke.
I WR # 100237 CRD 30-23, replace 126 valve diaphragm. A pre and post valve l time taken by I6C. {
WR # 100219 CRD 30-23, replace 126 valve diaphragm-done on WR 100237. l t
WR # 111531 CRD 30-31, renove, inspect and replace the 126 valve diaphragm. !
Retimed valve stroke. f WR # I11533 CRD 30-31, remove, inspect and replace the 127 valre diaphragm.
Retimed "al_ve stroke.
WR # 100220 CRD 30-31, replace 127 valve diaphragm. A pre and post valve time taken by I6C.
WR # 111896 Emergency condenser thermocouple 60-26-housing is cracked.
Replaced housing.
WR # 112009 RPS cabinets C and D drywell pressure inst.-difference between pressure and readings is outside the specified guide value per N1-ST-D0 - investigate and repair. Recalibrates meter.
WR # 106300 Reactor b1dg. emergency ventilation - system initiated for reasons not immediately obvious, investigate and repair. No problem.
WR # 112014 12 Control Room vent monitor - spiking, investigate and repair.
No repair - calibration check OK.
WR # 109406 DG102 crankcase pressure. Installed digital manometer to observe crankcase pressure.
l WR # 106295 High range refuel monitor-High lite on, will not reset, repair
- as necessary. Repaired on WR I11893.
WR # 111893 Power supply for rad nonitors 1 - ripple on 33V supply. Replaced filter cat uitor.
l l
i
NARRATIVE OF OPERATING EXPERIENCE g May 11, 1987 Page 4 CLASS I WORK - INSTRUMENT AND CONTROL - APRIL 1987(ConM WR # 112010 APRM 14-scram setpoint at 20% power - 1% too high. Recalibrates.
WR # 111805 Master trip unit - trip adjust operates unpredictable, trip potentiometer appears worn. Master trip unit will be sent back to factory for repair.
WR # 100221 CRD 30-31, replace 126 valve diaphragm. A pre and post valve time taken by I6C.
1 l
l t . ___ _ ___ .d
i R' U 0M7 4 l N
2 8 . 7 o e e
(
r 2
- e/W%
n6 0 i / . 4 t
n s
nta nF el si
- 5 NS T3 o ioa e c) e e C tcfL DiR v c u o E i
n r t r
s nfo(
rL o
t
_ c e
- O.EEYE N MTBN e
r or iu r
f e g
Ino is r n
o AA DO r - ta te T N o,e CoiR c *5 n Gah r ep e
DEH E 6 a pS R TP
. e KT I E L E &t c eAn t
5h c
i e b r yt n1
)
CN L s e ox h i Prtnv1 e6 PE
_ r OU u v e t E x o D MT a EfEE0 O
C P r
d e
_ C a c 4
_ o n l e u
d q e e c S u
dd e o R R S
N .
O .
m I
T .yO . ar )n C 7 mci a aSl U 8 ~c g} r p D 9 ci cx 1 St aE E : la la C L donnt uu m oe (r 2 I R h E .7u h a a ut W P A E.uN teMMAO - - - -
O <
M1 234 P
D H 3 N T A N S O a N M 5 tns t W T e o O R 'C Ev ep D O I
n P
L R o T i U E ta H R n S im T a I :.3:a g 6 x N mE;5 )
E U i n e s
.:s 7E. j lp a n e
x c ni E oL
.5M5 ic&
(t 1
e s t r 1 r e is g luT f i n si iao e n F e Riv ai
- 3 6 tnn c
gr yTr a ea or t
=52$ 2 oi mnni pt el el tat ui a
- ns o uif s g a e e pd pt a
nu ge aEMRROA e - -
~Em S RABCD1.FGI 2
1 1
it 4 0
th 7 8 l i
d leu ed c e r
o hc F S
% FS l
s i
l,
/
l des 1GHA M M Ob'"L //
/ HN Certified 3 b - $
c' , . . NIAGARA MOH AWK POWER CORPORATION NMP25550 M
<- d*4 ) NtAGARA MOHAWK L/M 301 PLAINFIELD ROAD SYRACUSF.NY 13212 i THOMA as mies.,S E LEMPOES
_.uca . inaw.
May 11, 1987 i
l l
Director, Of fice of Management Information & Program Control ,
U.S. Nuclear Regulatory Commission l Washington, D.C. 20555 j ATTENTION: Document and Control Desk .
1
SUBJECT:
Operating Statistics & Shutdoim - April 1987 j Docket No. 50-220 NINE MILE POINT UNIT I l
l
Dear Sir:
Submitted herewith is the Report of Operating Statistics and Shutdown
[
for April for the Nine Mile Point Nuclear Station Unit 1.
Also included is a narrative report of Operating Experience for j l April 1987. !
l Very truly yours, w 94 Thomas E. Lempges j Vice President 1 Nuclear Generation l TEL/djt i i
1 Attachments '
xc: Director, Office of I&E (10)
G' h \
i f
I .)