ML20237H815

From kanterella
Jump to navigation Jump to search
Corrected Monthly Operating Repts for Feb 1987
ML20237H815
Person / Time
Site: Prairie Island  
Issue date: 02/28/1987
From: Dugstad D
NORTHERN STATES POWER CO.
To:
Shared Package
ML20237H610 List:
References
NUDOCS 8708170368
Download: ML20237H815 (2)


Text

.

OEEEeIING_ Dele _REEDEI DOCKET No. 50-292 UNIT PRAIRIE ISLAND N0.1 DATE MARCH 3, 1987 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-ii21 OEEEeIING_SIoIUI

1. UNIT NAME:

E86IBIE_ISLeUD_NO _1 l

l NOTES:

2.

REPORTING PERIOD:_EEEEUGEY___1282___

j l (} gyre c_jr4

/.% 418

3. LICENSED THERMAL POWER (MWT) 1650
4. NAMEPLATE RATING (GROSS MWE) 593 l

1

5. DESIGN ELECTRICAL RATING (NET MWE) 530 l

1

6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE)- 534 l

l 7.

MAXIMUM DL 'ENDABLE CAPACITY (NET MWE)*

503 L____________________1 8.

IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7) j SINCE LAST REPORT GIVE REASON:

UQUE_______________________________

9.

POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE)-

_MONE______________

10. REASONS FOR RESTRICTIONS, IF ANY:__NDNE_______________________________

IBIS _dONIB YE:IO:DeIE CUduLeIIVE ii. HOURS IN REPORTING PERIOD 672 1416 115752

12. NUMBER OF HOURS REACTOR WAS CRITICAL 479.6 1223.6 96479.2
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 5571.1
14. HOURS GENERATOR ON-LINE 479.6 1223.6 95097.3
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 781962 1995534 149602502
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 264080 674030 48936020
18. NET ELECTRICAL ENERGY GENERATED (MWH) 250373 640199G7 458875Ge (/

I

19. UNIT SERVICE FACTOR 71.4 86.4 82.2
20. UNIT AVAILABILITY FACTOR 71.4 86.4 82.2
21. UNIT CAPACITY FACTOR (USING MDC NET) 74.1 89.9 78.8
22. UNIT CAPACITY FACTOR (USING DER NET) 70.3 85.3 74.8
23. UNIT FORCED OUTAGE RATE 28.6 13.6 7.i
24. FORCED OUTAGE HOURS 192.4 192.4 7304.7
25. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE & DURATION OF EACH)

BEEUELING_QUIeGE_eEBIL_8._1282._ IBIS _deY_CBeNGE DUE_ID_E0BCED_QUIeGE.__

26. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP DATE:_______.UZa_______________

e 8708170368 870811 ADOCK 0%g2 PDR L

..c QEE86IING_ Dele _8EE0BI DOCKET No. 50-306_

UNIT PRAIRIE ISLAND NO22 DATE MARCH 3, 1987 COMPLETED BY DALE DUGSTAD TELEPHONE 612-388-1121 QEEBaIING_SIeIUI

1. UNIT NAME:

P86181E_lSL6UD_UQi_2 gdd bne @1 l NOTES:

2. REPORTING PERIOD:_EEBRUe8Y___1282___
3. LICENSED THERMAL POWER (MWT) 1650 I

4.

NAMEPLATE RATING (GROSS MWE) 593 I

I

5. DESIGN ELECTRICAL RATING (NET MWE):

530 1

I

6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE) 531 l

1 7.

MAXIMUM DEPENDABLE CAPACITY (NET MWE) 500 1___________________ 1 8.

IF CF'ANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH ?)

SINCE LAST REPORT GIVE REASON:__NOUE______________________________

9.

POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE):__UQUE______________

10. REASONS FOR RESTRICTIONS, IF ANY:__NDUE_______________________________

IBIS _dOUIB YE ID:DeIE CUduLeIIVE

11. HOURS IN REPORTING PERIOD 672 1416 106870
12. NUMBER OF HOURS REACTOR WAS CRITICAL 672.0 1416.0 92891.4
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1516.1
14. HOURS GENERATOR ON-LINE 672.0 1416.0 91850.8
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 40N COS F 200251'* *

-i143012!' ***

i

17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 370490 782000 46599080
18. NET ELECTRICAL ENERGY GENERATED (MWH) 352934 745+e9 071 44094965r
19. UNIT SERVICE FACTOR 100.0 100.0 85.9
20. UNIT AVAILABILITY FACTOR 100.0 100.0 85.9
21. UNIT CAPACITY FACTOR (USING MDC NET) 105.0 105.2 82.5
22. UNIT CAPACITY FACTOR (USING DER NET)

.99.1 99.3 77.8

23. UNIT FORCED OUTAGE RATE 0.0 0.0 3.4 l
24. FORCED OUTAGE HOURS 0.0 0.0 3253.1
25. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS iTYPE, DATE & DURATION OF EACH) 47dI

________________________________U_L_e_____________________________-_

26. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP DATEl_____U_2_e_______________

% lo969c4 h >3l% 90?

1445 t h 763

--